BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 15194089)

  • 1. Surface engineering of prosthetic knee components.
    Nevelos J
    Knee; 2004 Jun; 11(3):163-7. PubMed ID: 15194089
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of design, materials and kinematics on the in vitro wear of total knee replacements.
    McEwen HM; Barnett PI; Bell CJ; Farrar R; Auger DD; Stone MH; Fisher J
    J Biomech; 2005 Feb; 38(2):357-65. PubMed ID: 15598464
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Wear of contemporary total knee replacements--a knee simulator study of six current designs.
    Utzschneider S; Harrasser N; Schroeder C; Mazoochian F; Jansson V
    Clin Biomech (Bristol, Avon); 2009 Aug; 24(7):583-8. PubMed ID: 19450910
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved wear performance with crosslinked UHMWPE and zirconia implants in knee simulation.
    Tsukamoto R; Chen S; Asano T; Ogino M; Shoji H; Nakamura T; Clarke IC
    Acta Orthop; 2006 Jun; 77(3):505-11. PubMed ID: 16819693
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study.
    Kretzer JP; Jakubowitz E; Reinders J; Lietz E; Moradi B; Hofmann K; Sonntag R
    Acta Biomater; 2011 Feb; 7(2):710-5. PubMed ID: 20883831
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new method of in vitro wear assessment of the UHMWPE tibial insert in total knee replacement.
    Affatato S; Cristofolini L; Leardini W; Erani P; Zavalloni M; Tigani D; Viceconti M
    Artif Organs; 2008 Dec; 32(12):942-8. PubMed ID: 19133022
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mobile-bearing knees reduce rotational asymmetric wear.
    Ho FY; Ma HM; Liau JJ; Yeh CR; Huang CH
    Clin Orthop Relat Res; 2007 Sep; 462():143-9. PubMed ID: 17483732
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Delamination and adhesive wear behavior of alpha-tocopherol-stabilized irradiated ultrahigh-molecular-weight polyethylene.
    Wannomae KK; Christensen SD; Micheli BR; Rowell SL; Schroeder DW; Muratoglu OK
    J Arthroplasty; 2010 Jun; 25(4):635-43. PubMed ID: 19493652
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ceramic versus cobalt-chrome femoral components; wear of polyethylene insert in total knee prosthesis.
    Oonishi H; Ueno M; Kim SC; Oonishi H; Iwamoto M; Kyomoto M
    J Arthroplasty; 2009 Apr; 24(3):374-82. PubMed ID: 18524533
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Material and surface factors influencing backside fretting wear in total knee replacement tibial components.
    Billi F; Sangiorgio SN; Aust S; Ebramzadeh E
    J Biomech; 2010 May; 43(7):1310-5. PubMed ID: 20172525
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Contemporary unicompartmental knee arthroplasty: fixed vs mobile bearing.
    Bonutti PM; Dethmers DA
    J Arthroplasty; 2008 Oct; 23(7 Suppl):24-7. PubMed ID: 18922370
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Posteromedial tibial polyethylene failure in total knee replacements.
    Lewis P; Rorabeck CH; Bourne RB; Devane P
    Clin Orthop Relat Res; 1994 Feb; (299):11-7. PubMed ID: 8119004
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Increased force simulator wear testing of a zirconium oxide total knee arthroplasty.
    Lee JK; Maruthainar K; Wardle N; Haddad F; Blunn GW
    Knee; 2009 Aug; 16(4):269-74. PubMed ID: 19321347
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect on wear of lift-off in total knee arthroplasty.
    Todo S; Blunn GW; Harrison M; Freeman MA
    Biomed Mater Eng; 2003; 13(3):231-4. PubMed ID: 12883172
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mobile-bearing knee systems: ultra-high molecular weight polyethylene wear and design issues.
    Greenwald AS; Heim CS
    Instr Course Lect; 2005; 54():195-205. PubMed ID: 15948447
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties--a comparison between mobile bearing and fixed bearing knees.
    Huang CH; Ho FY; Ma HM; Yang CT; Liau JJ; Kao HC; Young TH; Cheng CK
    J Orthop Res; 2002 Sep; 20(5):1038-41. PubMed ID: 12382971
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pop-top tibial component: elimination of back-side wear with potential modularity.
    Lombardi AV; Berend KR; Mallory TH
    Surg Technol Int; 2004; 13():253-60. PubMed ID: 15744698
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mobile-bearing total knee arthroplasty: design factors in minimizing wear.
    Dennis DA; Komistek RD
    Clin Orthop Relat Res; 2006 Nov; 452():70-7. PubMed ID: 16924175
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Oxidation-induced dynamic changes in morphology reflected on freeze-fractured surface of gamma-irradiated ultra-high molecular weight polyethylene components.
    Watanabe E; Suzuki M; Nagata K; Kaneeda T; Harada Y; Utsumi M; Mori A; Moriya H
    J Biomed Mater Res; 2002 Dec; 62(4):540-9. PubMed ID: 12221702
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An observation on subsurface defects of ultra high molecular weight polyethylene due to rolling contact.
    Ohashi M; Tomita N; Ikada Y; Ikeuchi K; Motoike T
    Biomed Mater Eng; 1996; 6(6):441-51. PubMed ID: 9138654
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.