These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
150 related articles for article (PubMed ID: 15197629)
1. Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems. Lehmann W; Briem D; Blauth M; Schmidt U Eur Spine J; 2005 Apr; 14(3):243-9. PubMed ID: 15197629 [TBL] [Abstract][Full Text] [Related]
2. Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase. Lehmann W; Blauth M; Briem D; Schmidt U Eur Spine J; 2004 Feb; 13(1):69-75. PubMed ID: 14685829 [TBL] [Abstract][Full Text] [Related]
3. The effect of locking fixation screws on the stability of anterior cervical plating. Spivak JM; Chen D; Kummer FJ Spine (Phila Pa 1976); 1999 Feb; 24(4):334-8. PubMed ID: 10065516 [TBL] [Abstract][Full Text] [Related]
4. Biomechanical evaluation of a newly developed monocortical expansion screw for use in anterior internal fixation of the cervical spine. In vitro comparison with two established internal fixation systems. Richter M; Wilke HJ; Kluger P; Claes L; Puhl W Spine (Phila Pa 1976); 1999 Feb; 24(3):207-12. PubMed ID: 10025014 [TBL] [Abstract][Full Text] [Related]
5. Biomechanical evaluation of Caspar and Cervical Spine Locking Plate systems in a cadaveric model. Clausen JD; Ryken TC; Traynelis VC; Sawin PD; Dexter F; Goel VK J Neurosurg; 1996 Jun; 84(6):1039-45. PubMed ID: 8847569 [TBL] [Abstract][Full Text] [Related]
6. Biomechanical comparison of a novel C1 posterior locking plate with the harms technique in a C1-C2 fixation model. Kelly BP; Glaser JA; DiAngelo DJ Spine (Phila Pa 1976); 2008 Nov; 33(24):E920-5. PubMed ID: 19011532 [TBL] [Abstract][Full Text] [Related]
7. A biomechanical comparison of modern anterior and posterior plate fixation of the cervical spine. Do Koh Y; Lim TH; Won You J; Eck J; An HS Spine (Phila Pa 1976); 2001 Jan; 26(1):15-21. PubMed ID: 11148640 [TBL] [Abstract][Full Text] [Related]
9. [Anterior cervical fusion on the lower cervical spine: own clinical experience]. Pazdernyik S; Sándor L; Elek P; Barzó P Ideggyogy Sz; 2010 Jan; 63(1-2):25-37. PubMed ID: 20420121 [TBL] [Abstract][Full Text] [Related]
10. A Novel Anterior Odontoid Screw Plate for C1-C3 Internal Fixation: An In Vitro Biomechanical Study. Hu Y; Dong WX; Kepler CK; Yuan ZS; Sun XY; Zhang J; Xie H Spine (Phila Pa 1976); 2016 Jan; 41(2):E64-72. PubMed ID: 26555834 [TBL] [Abstract][Full Text] [Related]
11. Cervical stability with lateral mass plating: unicortical versus bicortical screw purchase. Muffoletto AJ; Yang J; Vadhva M; Hadjipavlou AG Spine (Phila Pa 1976); 2003 Apr; 28(8):778-81. PubMed ID: 12698120 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of a new monocortical screw for anterior cervical fusion and plating by a combined biomechanical and clinical study. Pitzen T; Wilke HJ; Caspar W; Claes L; Steudel WI Eur Spine J; 1999; 8(5):382-7. PubMed ID: 10552321 [TBL] [Abstract][Full Text] [Related]
13. Anterior subaxial cervical spine fixation using a plate with single screw per vertebral body: a simple and efficient construct - clinical series and a cadaver study. Vannemreddy PS; Ogden A; Mukherjee D Neurol India; 2009; 57(2):151-6. PubMed ID: 19439844 [TBL] [Abstract][Full Text] [Related]
14. Biomechanics of an integrated interbody device versus ACDF anterior locking plate in a single-level cervical spine fusion construct. Stein MI; Nayak AN; Gaskins RB; Cabezas AF; Santoni BG; Castellvi AE Spine J; 2014 Jan; 14(1):128-36. PubMed ID: 24231054 [TBL] [Abstract][Full Text] [Related]
15. Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine. Kotani Y; Cunningham BW; Abumi K; McAfee PC Spine (Phila Pa 1976); 1994 Nov; 19(22):2529-39. PubMed ID: 7855677 [TBL] [Abstract][Full Text] [Related]
16. Biomechanical evaluation of locking plate radial shaft fixation: unicortical locking fixation versus mixed bicortical and unicortical fixation in a sawbone model. Roberts JW; Grindel SI; Rebholz B; Wang M J Hand Surg Am; 2007 Sep; 32(7):971-5. PubMed ID: 17826548 [TBL] [Abstract][Full Text] [Related]
17. Anterior cervical discectomy and fusion with a locked plate and wedged graft effectively stabilizes flexion-distraction stage-3 injury in the lower cervical spine: a biomechanical study. Paxinos O; Ghanayem AJ; Zindrick MR; Voronov LI; Havey RM; Carandang G; Hadjipavlou A; Patwardhan AG Spine (Phila Pa 1976); 2009 Jan; 34(1):E9-15. PubMed ID: 19127153 [TBL] [Abstract][Full Text] [Related]
18. Biomechanical comparison of transfacet screws to lateral mass screw-rod constructs in the lower cervical spine. Tong J; Ji W; Zhou R; Huang Z; Liu S; Zhu Q Eur Spine J; 2016 Jun; 25(6):1787-93. PubMed ID: 26530298 [TBL] [Abstract][Full Text] [Related]
19. Screw angulation affects bone-screw stresses and bone graft load sharing in anterior cervical corpectomy fusion with a rigid screw-plate construct: a finite element model study. Hussain M; Natarajan RN; Fayyazi AH; Braaksma BR; Andersson GB; An HS Spine J; 2009 Dec; 9(12):1016-23. PubMed ID: 19819193 [TBL] [Abstract][Full Text] [Related]
20. [Ventral interbody spondylodesis in injuries of the cervical spine. Indications, surgical technique and results]. Blauth M; Schmidt U; Bastian L; Knop C; Tscherne H Zentralbl Chir; 1998; 123(8):919-29. PubMed ID: 9757537 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]