These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

246 related articles for article (PubMed ID: 15199304)

  • 1. Determination of central aortic systolic and pulse pressure from the radial artery pressure waveform.
    Adji A; O'Rourke MF
    Blood Press Monit; 2004 Jun; 9(3):115-21. PubMed ID: 15199304
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noninvasive assessment of local pulse pressure: importance of brachial-to-radial pressure amplification.
    Verbeke F; Segers P; Heireman S; Vanholder R; Verdonck P; Van Bortel LM
    Hypertension; 2005 Jul; 46(1):244-8. PubMed ID: 15911747
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform.
    Pauca AL; O'Rourke MF; Kon ND
    Hypertension; 2001 Oct; 38(4):932-7. PubMed ID: 11641312
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Peripheral blood pressure measurement is as good as applanation tonometry at predicting ascending aortic blood pressure.
    Davies JI; Band MM; Pringle S; Ogston S; Struthers AD
    J Hypertens; 2003 Mar; 21(3):571-6. PubMed ID: 12640251
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulse pressure amplification, pressure waveform calibration and clinical applications.
    Agnoletti D; Zhang Y; Salvi P; Borghi C; Topouchian J; Safar ME; Blacher J
    Atherosclerosis; 2012 Sep; 224(1):108-12. PubMed ID: 22832004
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical use of indices determined non-invasively from the radial and carotid pressure waveforms.
    Adji A; Hirata K; O'Rourke MF
    Blood Press Monit; 2006 Aug; 11(4):215-21. PubMed ID: 16810032
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Augmentation of the aortic and central arterial pressure waveform.
    O'Rourke MF; Pauca AL
    Blood Press Monit; 2004 Aug; 9(4):179-85. PubMed ID: 15311144
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Relationship between radial and central arterial pulse wave and evaluation of central aortic pressure using the radial arterial pulse wave.
    Takazawa K; Kobayashi H; Shindo N; Tanaka N; Yamashina A
    Hypertens Res; 2007 Mar; 30(3):219-28. PubMed ID: 17510503
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pressure wave reflection assessed from the peripheral pulse: is a transfer function necessary?
    Millasseau SC; Patel SJ; Redwood SR; Ritter JM; Chowienczyk PJ
    Hypertension; 2003 May; 41(5):1016-20. PubMed ID: 12695415
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform characteristics.
    Hope SA; Meredith IT; Cameron JD
    Clin Sci (Lond); 2004 Aug; 107(2):205-11. PubMed ID: 15139848
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noninvasive measurement of central vascular pressures with arterial tonometry: clinical revival of the pulse pressure waveform?
    Nelson MR; Stepanek J; Cevette M; Covalciuc M; Hurst RT; Tajik AJ
    Mayo Clin Proc; 2010 May; 85(5):460-72. PubMed ID: 20435839
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cuff and aortic pressure differences during dobutamine infusion: a study of the effects of systolic blood pressure amplification.
    Smulyan H; Mukherjee R; Sheehe PR; Safar ME
    Am Heart J; 2010 Mar; 159(3):399-405. PubMed ID: 20211301
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Central aortic blood pressure estimation in children and adolescents: results of the KidCoreBP study.
    Mynard JP; Goldsmith G; Springall G; Eastaugh L; Lane GK; Zannino D; Smolich JJ; Avolio A; Cheung MMH
    J Hypertens; 2020 May; 38(5):821-828. PubMed ID: 31790068
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relationship between augmentation index obtained from carotid and radial artery pressure waveforms.
    Sugawara J; Komine H; Hayashi K; Maeda S; Matsuda M
    J Hypertens; 2007 Feb; 25(2):375-81. PubMed ID: 17211244
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Pressure wave shape comparison between two non-invasive tonometric devices].
    Agnoletti D; Millasseau S; Topouchian J; Zhang Y; Safar ME; Blacher J
    Ann Cardiol Angeiol (Paris); 2013 Jun; 62(3):193-9. PubMed ID: 23721987
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of a generalized transfer function to noninvasively derive central blood pressure during exercise.
    Sharman JE; Lim R; Qasem AM; Coombes JS; Burgess MI; Franco J; Garrahy P; Wilkinson IB; Marwick TH
    Hypertension; 2006 Jun; 47(6):1203-8. PubMed ID: 16651459
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of the N-point moving average method for brachial pressure waveform-derived estimation of central aortic systolic pressure.
    Shih YT; Cheng HM; Sung SH; Hu WC; Chen CH
    Hypertension; 2014 Apr; 63(4):865-70. PubMed ID: 24420554
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry.
    Fetics B; Nevo E; Chen CH; Kass DA
    IEEE Trans Biomed Eng; 1999 Jun; 46(6):698-706. PubMed ID: 10356876
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The accuracy of central SBP determined from the second systolic peak of the peripheral pressure waveform.
    Hickson SS; Butlin M; Mir FA; Graggaber J; Cheriyan J; Khan F; Grace AA; Yasmin ; Cockcroft JR; Wilkinson IB; McEniery CM;
    J Hypertens; 2009 Sep; 27(9):1784-8. PubMed ID: 19702000
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Brachial artery tonometry and the Popeye phenomenon: explanation of anomalies in generating central from upper limb pressure waveforms.
    Adji A; O'Rourke MF
    J Hypertens; 2012 Aug; 30(8):1540-51. PubMed ID: 22635139
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.