These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 15200386)

  • 1. Effect of stationary phase structure on retention and selectivity tuning in the high-throughput separation of tocopherol isomers by HPLC.
    Buszewski B; Krupczynska K; Bazylak G
    Comb Chem High Throughput Screen; 2004 Jun; 7(4):383-91. PubMed ID: 15200386
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of pressure on the selectivity of polymeric C18 and C30 stationary phases in reversed-phase liquid chromatography. Increased separation of isomeric fatty acid methyl esters, triacylglycerols, and tocopherols at high pressure.
    Okusa K; Iwasaki Y; Kuroda I; Miwa S; Ohira M; Nagai T; Mizobe H; Gotoh N; Ikegami T; McCalley DV; Tanaka N
    J Chromatogr A; 2014 Apr; 1339():86-95. PubMed ID: 24666940
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Separation of tocopherol isomers using capillary electrochromatography: comparison of monomeric and polymeric C30 stationary phases.
    Henry CW; Fortier CA; Warner IM
    Anal Chem; 2001 Dec; 73(24):6077-82. PubMed ID: 11791583
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of a polar-embedded stationary phase for the separation of tocopherols by CEC.
    Carabias-Martínez R; Rodríguez-Gonzalo E; Smith NW; Ruano-Miguel L
    Electrophoresis; 2006 Nov; 27(22):4423-30. PubMed ID: 17058307
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of mobile phase on resolution of the isomers and homologues of tocopherols on a triacontyl stationary phase.
    Saha S; Walia S; Kundu A; Pathak N
    Anal Bioanal Chem; 2013 Nov; 405(28):9285-95. PubMed ID: 24077829
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Distinction of synthetic dl-α-tocopherol from natural vitamin E (d-α-tocopherol) by reversed-phase liquid chromatography. Enhanced selectivity of a polymeric C18 stationary phase at low temperature and/or at high pressure.
    Yui Y; Miyazaki S; Ma Y; Ohira M; Fiehn O; Ikegami T; McCalley DV; Tanaka N
    J Chromatogr A; 2016 Jun; 1450():45-52. PubMed ID: 27157422
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Facile preparation of an alternating copolymer-based high molecular shape-selective organic phase for reversed-phase liquid chromatography.
    Mallik AK; Noguchi H; Rahman MM; Takafuji M; Ihara H
    J Chromatogr A; 2018 Jun; 1555():53-61. PubMed ID: 29706403
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monitoring the interactions of tocopherol homologues with reversed-phase stationary HPLC phases by 1H suspended-state saturation transfer difference high-resolution/magic angle spinning NMR spectroscopy.
    Schauff S; Friebolin V; Grynbaum MD; Meyer C; Albert K
    Anal Chem; 2007 Nov; 79(21):8323-6. PubMed ID: 17918907
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Post-synthetic modification of MIL-101(Cr) with pyridine for high-performance liquid chromatographic separation of tocopherols.
    Yang F; Yang CX; Yan XP
    Talanta; 2015 May; 137():136-42. PubMed ID: 25770616
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of the mobile phase pH and the stationary phase type on the selectivity tuning in high performance liquid chromatography nucleosides separation.
    Kowalska S; Krupczyńska K; Buszewski B
    J Sep Sci; 2005 Aug; 28(13):1502-11. PubMed ID: 16158992
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Shape selectivity of C30 phases for RP-HPLC separation of tocopherol isomers and correlation with MAS NMR data from suspended stationary phases.
    Strohschein S; Pursch M; Lubda D; Albert K
    Anal Chem; 1998 Jan; 70(1):13-8. PubMed ID: 9435466
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Retention properties of novel beta-CD bonded stationary phases in reversed-phase HPLC mode.
    Zhao Y; Guo Z; Zhang Y; Xue X; Xu Q; Li X; Liang X; Zhang Y
    Talanta; 2009 May; 78(3):916-21. PubMed ID: 19269450
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Repeatability in column preparation of a reversed-phase C18 monolith and its application to separation of tocopherol homologues.
    Kositarat S; Smith NW; Nacapricha D; Wilairat P; Chaisuwan P
    Talanta; 2011 Jun; 84(5):1374-8. PubMed ID: 21641454
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous determination of carotenoids, tocopherols, and gamma-oryzanol in crude rice bran oil by liquid chromatography coupled to diode array and mass spectrometric detection employing silica C30 stationary phases.
    Stöggl W; Huck C; Wongyai S; Scherz H; Bonn G
    J Sep Sci; 2005 Sep; 28(14):1712-8. PubMed ID: 16224965
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Suitability of stationary phase for LC analysis of biomolecules.
    Saha S; Walia S; Sharma K; Banerjee K
    Crit Rev Food Sci Nutr; 2020; 60(17):2856-2873. PubMed ID: 31621391
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Separation of tocopherol and tocotrienol isomers using normal- and reverse-phase liquid chromatography.
    Tan B; Brzuskiewicz L
    Anal Biochem; 1989 Aug; 180(2):368-73. PubMed ID: 2817368
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Separation of alpha-, beta-, gamma-, delta-tocopherols and alpha-tocopherol acetate on a pentaerythritol diacrylate monostearate-ethylene dimethacrylate monolith by capillary electrochromatography.
    Chaisuwan P; Nacapricha D; Wilairat P; Jiang Z; Smith NW
    Electrophoresis; 2008 Jun; 29(11):2301-9. PubMed ID: 18548461
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Separations of substituted benzenes and polycyclic aromatic hydrocarbons using normal- and reverse-phase high performance liquid chromatography with UiO-66 as the stationary phase.
    Zhao WW; Zhang CY; Yan ZG; Bai LP; Wang X; Huang H; Zhou YY; Xie Y; Li FS; Li JR
    J Chromatogr A; 2014 Nov; 1370():121-8. PubMed ID: 25454136
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative study of hydrocarbon, fluorocarbon, and aromatic bonded RP-HPLC stationary phases by linear solvation energy relationships.
    Reta M; Carr PW; Sadek PC; Rutan SC
    Anal Chem; 1999 Aug; 71(16):3484-96. PubMed ID: 10464478
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preparation and evaluation of pillararene bonded silica gel stationary phases for high performance liquid chromatography.
    Zhao W; Chu J; Xie F; Duan Q; He L; Zhang S
    J Chromatogr A; 2017 Feb; 1485():44-51. PubMed ID: 28108079
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.