BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

201 related articles for article (PubMed ID: 15202111)

  • 1. Evaluation of an image-guided, robotically positioned transcranial magnetic stimulation system.
    Lancaster JL; Narayana S; Wenzel D; Luckemeyer J; Roby J; Fox P
    Hum Brain Mapp; 2004 Aug; 22(4):329-40. PubMed ID: 15202111
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Positron emission tomography during transcranial magnetic stimulation does not require mu-metal shielding.
    Lee JS; Narayana S; Lancaster J; Jerabek P; Lee DS; Fox P
    Neuroimage; 2003 Aug; 19(4):1812-9. PubMed ID: 12948735
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI.
    Bohning DE; Denslow S; Bohning PA; Walker JA; George MS
    Clin Neurophysiol; 2003 Nov; 114(11):2210-9. PubMed ID: 14580621
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of stereotaxic positioning of transcranial magnetic stimulation.
    Schönfeldt-Lecuona C; Thielscher A; Freudenmann RW; Kron M; Spitzer M; Herwig U
    Brain Topogr; 2005; 17(4):253-9. PubMed ID: 16110774
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computational and experimental analysis of TMS-induced electric field vectors critical to neuronal activation.
    Krieg TD; Salinas FS; Narayana S; Fox PT; Mogul DJ
    J Neural Eng; 2015 Aug; 12(4):046014. PubMed ID: 26052136
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A stereotactic method for image-guided transcranial magnetic stimulation validated with fMRI and motor-evoked potentials.
    Neggers SF; Langerak TR; Schutter DJ; Mandl RC; Ramsey NF; Lemmens PJ; Postma A
    Neuroimage; 2004 Apr; 21(4):1805-17. PubMed ID: 15050601
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A triangulation-based magnetic resonance image-guided method for transcranial magnetic stimulation coil positioning.
    Andoh J; Riviere D; Mangin JF; Artiges E; Cointepas Y; Grevent D; Paillère-Martinot ML; Martinot JL; Cachia A
    Brain Stimul; 2009 Jul; 2(3):123-31. PubMed ID: 20633411
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Physiological observations validate finite element models for estimating subject-specific electric field distributions induced by transcranial magnetic stimulation of the human motor cortex.
    Opitz A; Legon W; Rowlands A; Bickel WK; Paulus W; Tyler WJ
    Neuroimage; 2013 Nov; 81():253-264. PubMed ID: 23644000
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-sensitivity TMS/fMRI of the Human Motor Cortex Using a Dedicated Multichannel MR Coil.
    Navarro de Lara LI; Tik M; Woletz M; Frass-Kriegl R; Moser E; Laistler E; Windischberger C
    Neuroimage; 2017 Apr; 150():262-269. PubMed ID: 28254457
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy and precision of navigated transcranial magnetic stimulation.
    Nieminen AE; Nieminen JO; Stenroos M; Novikov P; Nazarova M; Vaalto S; Nikulin V; Ilmoniemi RJ
    J Neural Eng; 2022 Dec; 19(6):. PubMed ID: 36541458
    [No Abstract]   [Full Text] [Related]  

  • 11. Accuracy of robotic coil positioning during transcranial magnetic stimulation.
    Goetz SM; Kozyrkov IC; Luber B; Lisanby SH; Murphy DLK; Grill WM; Peterchev AV
    J Neural Eng; 2019 Sep; 16(5):054003. PubMed ID: 31189147
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Proposal for an accurate TMS-MRI co-registration process via 3D laser scanning.
    Hironaga N; Kimura T; Mitsudo T; Gunji A; Iwata M
    Neurosci Res; 2019 Jul; 144():30-39. PubMed ID: 30170008
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel low-cost approach for navigated transcranial magnetic stimulation.
    Rodseth J; Washabaugh EP; Krishnan C
    Restor Neurol Neurosci; 2017; 35(6):601-609. PubMed ID: 29036851
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A high-resolution computational localization method for transcranial magnetic stimulation mapping.
    Aonuma S; Gomez-Tames J; Laakso I; Hirata A; Takakura T; Tamura M; Muragaki Y
    Neuroimage; 2018 May; 172():85-93. PubMed ID: 29360575
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New coil positioning method for interleaved transcranial magnetic stimulation (TMS)/functional MRI (fMRI) and its validation in a motor cortex study.
    Moisa M; Pohmann R; Ewald L; Thielscher A
    J Magn Reson Imaging; 2009 Jan; 29(1):189-97. PubMed ID: 19097080
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Non-orthogonal one-step calibration method for robotized transcranial magnetic stimulation.
    Wang H; Jin J; Wang X; Li Y; Liu Z; Yin T
    Biomed Eng Online; 2018 Oct; 17(1):137. PubMed ID: 30285787
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Functional magnetic resonance imaging and transcranial magnetic stimulation: effects of motor imagery, movement and coil orientation.
    Niyazov DM; Butler AJ; Kadah YM; Epstein CM; Hu XP
    Clin Neurophysiol; 2005 Jul; 116(7):1601-10. PubMed ID: 15953559
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Robotic TMS mapping of motor cortex in the developing brain.
    Grab JG; Zewdie E; Carlson HL; Kuo HC; Ciechanski P; Hodge J; Giuffre A; Kirton A
    J Neurosci Methods; 2018 Nov; 309():41-54. PubMed ID: 30121208
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Localizing Broca's area for transcranial magnetic stimulation: Comparison of surface distance measurements and stereotaxic positioning.
    Weiduschat N; Habedank B; Lampe B; Poggenborg J; Schuster A; Haupt WF; Heiss WD; Thiel A
    Brain Stimul; 2009 Apr; 2(2):93-102. PubMed ID: 20633406
    [TBL] [Abstract][Full Text] [Related]  

  • 20. BRAIN initiative: transcranial magnetic stimulation automation and calibration.
    Todd GD; Abdellatif A; Sabouni A
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():502-5. PubMed ID: 25570006
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.