BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

377 related articles for article (PubMed ID: 15209580)

  • 1. Mechanisms for enlarging lesion size during irrigated tip radiofrequency ablation: is there a virtual electrode effect?
    Petersen HH; Roman-Gonzalez J; Johnson SB; Hastrup Svendsen J; HaunsØ S; Packer DL
    J Interv Cardiol; 2004 Jun; 17(3):171-7. PubMed ID: 15209580
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Safety profiles and lesion size of different radiofrequency ablation technologies: a comparison of large tip, open and closed irrigation catheters.
    Everett TH; Lee KW; Wilson EE; Guerra JM; Varosy PD; Olgin JE
    J Cardiovasc Electrophysiol; 2009 Mar; 20(3):325-35. PubMed ID: 18803562
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Indication of the radiofrequency induced lesion size by pre-ablation measurements.
    Stagegaard N; Petersen HH; Chen X; Svendsen JH
    Europace; 2005 Nov; 7(6):525-34. PubMed ID: 16216752
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of electrode orientation on lesion sizes produced by irrigated radiofrequency ablation catheters.
    Wood MA; Goldberg SM; Parvez B; Pathak V; Holland K; Ellenbogen AL; Han FT; Alexander D; Lau M; Reshko L; Goel A
    J Cardiovasc Electrophysiol; 2009 Nov; 20(11):1262-8. PubMed ID: 19572953
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro comparison of platinum-iridium and gold tip electrodes: lesion depth in 4 mm, 8 mm, and irrigated-tip radiofrequency ablation catheters.
    Linhart M; Mollnau H; Bitzen A; Wurtz S; Schrickel JW; Andrié R; Stöckigt F; Weiss C; Nickenig G; Lickfett LM; Lewalter T
    Europace; 2009 May; 11(5):565-70. PubMed ID: 19251707
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cooled intramural needle catheter ablation creates deeper lesions than irrigated tip catheter ablation.
    Thiagalingam A; Campbell CR; Boyd AC; Eipper VE; Ross DL; Kovoor P
    Pacing Clin Electrophysiol; 2004 Jul; 27(7):965-70. PubMed ID: 15271017
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Gold-tip electrodes--a new "deep lesion" technology for catheter ablation? In vitro comparison of a gold alloy versus platinum-iridium tip electrode ablation catheter.
    Lewalter T; Bitzen A; Wurtz S; Blum R; Schlodder K; Yang A; Lickfett L; Schwab JO; Schrickel JW; Tiemann K; Linhart M; Zima E; Merkely B; Lüderitz B
    J Cardiovasc Electrophysiol; 2005 Jul; 16(7):770-2. PubMed ID: 16050836
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of lesion sizes produced by cryoablation and open irrigation radiofrequency ablation catheters.
    Parvez B; Pathak V; Schubert CM; Wood M
    J Cardiovasc Electrophysiol; 2008 May; 19(5):528-34. PubMed ID: 18284508
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Temperature-controlled irrigated tip radiofrequency catheter ablation: comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate.
    Petersen HH; Chen X; Pietersen A; Svendsen JH; Haunsø S
    J Cardiovasc Electrophysiol; 1998 Apr; 9(4):409-14. PubMed ID: 9581956
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation.
    Pilcher TA; Sanford AL; Saul JP; Haemmerich D
    Pacing Clin Electrophysiol; 2006 Dec; 29(12):1368-74. PubMed ID: 17201844
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impedance and temperature monitoring improve the safety of closed-loop irrigated-tip radiofrequency ablation.
    Thiagalingam A; D'Avila A; McPherson C; Malchano Z; Ruskin J; Reddy VY
    J Cardiovasc Electrophysiol; 2007 Mar; 18(3):318-25. PubMed ID: 17313656
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Saline-irrigated radiofrequency ablation electrode with external cooling.
    Wittkampf FH; Nakagawa H; Foresti S; Aoyama H; Jackman WM
    J Cardiovasc Electrophysiol; 2005 Mar; 16(3):323-8. PubMed ID: 15817094
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of open-irrigated radiofrequency ablation catheter design on lesion formation and complications: in vitro comparison of 6 different devices.
    Guerra JM; Jorge E; Raga S; Gálvez-Montón C; Alonso-Martín C; Rodríguez-Font E; Cinca J; Viñolas X
    J Cardiovasc Electrophysiol; 2013 Oct; 24(10):1157-62. PubMed ID: 23718822
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling.
    Høgh Petersen H; Chen X; Pietersen A; Svendsen JH; Haunsø S
    Circulation; 1999 Jan; 99(2):319-25. PubMed ID: 9892601
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Anatomopathological and biochemical correlation of lesions produced by standard and irrigated 4 mm radiofrequency catheters].
    Hernández Madrid A; del Rey Sánchez JM; González Rebollo JM; Alvarez Mogollón T; Correa C; Ortiz Chercoles AI; Socas A; Lobelo R; Peña G; Mercader J; Ripoll E; Moro C
    Rev Esp Cardiol; 2000 Oct; 53(10):1347-55. PubMed ID: 11060253
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Large radiofrequency ablation lesions can be created with a retractable infusion-needle catheter.
    Sapp JL; Cooper JM; Zei P; Stevenson WG
    J Cardiovasc Electrophysiol; 2006 Jun; 17(6):657-61. PubMed ID: 16836718
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus.
    Yokoyama K; Nakagawa H; Shah DC; Lambert H; Leo G; Aeby N; Ikeda A; Pitha JV; Sharma T; Lazzara R; Jackman WM
    Circ Arrhythm Electrophysiol; 2008 Dec; 1(5):354-62. PubMed ID: 19808430
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: an in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation.
    Petersen HH; Chen X; Pietersen A; Svendsen JH; Haunsø S
    Pacing Clin Electrophysiol; 2000 Jan; 23(1):8-17. PubMed ID: 10666748
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Superiority of gold versus platinum irrigated tip catheter ablation of the pulmonary veins and the cavotricuspid isthmus: a randomized study comparing tip temperatures and cooling flow requirements.
    Linhart M; Liberman I; Schrickel JW; Mittmann-Braun EL; Andrié R; Stöckigt F; Kreuz J; Nickenig G; Lickfett LM
    J Cardiovasc Electrophysiol; 2012 Jul; 23(7):717-21. PubMed ID: 22429859
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter.
    Thiagalingam A; D'Avila A; Foley L; Guerrero JL; Lambert H; Leo G; Ruskin JN; Reddy VY
    J Cardiovasc Electrophysiol; 2010 Jul; 21(7):806-11. PubMed ID: 20132400
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.