These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 15212917)

  • 41. Flow characterization of the ADVANTAGE and St. Jude Medical bileaflet mechanical heart valves.
    Shu MC; O'Rourke KK; Coppin CM; Lemmon JD
    J Heart Valve Dis; 2004 Sep; 13(5):814-22. PubMed ID: 15473485
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [Numerical simulation of the relationship between blood pressure and blood stream of arteries].
    Shi X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Dec; 22(6):1121-3, 1127. PubMed ID: 16422080
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Quantitative evaluation of intra-aortic flow disturbance by the fluid momentum index: Effect of the left ventricular systolic function on the hemodynamics in the aorta.
    Nakamura M; Wada S; Yamaguchi T
    Technol Health Care; 2007; 15(2):111-20. PubMed ID: 17361055
    [TBL] [Abstract][Full Text] [Related]  

  • 44. An approach to the simulation of fluid-structure interaction in the aortic valve.
    Carmody CJ; Burriesci G; Howard IC; Patterson EA
    J Biomech; 2006; 39(1):158-69. PubMed ID: 16271600
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Numerical analysis of the hemodynamics and embolus capture of a greenfield vena cava filter.
    Swaminathan TN; Hu HH; Patel AA
    J Biomech Eng; 2006 Jun; 128(3):360-70. PubMed ID: 16706585
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Pressure and flow waves in systemic arteries and the anatomical design of the arterial system.
    O'Rourke MF
    J Appl Physiol; 1967 Aug; 23(2):139-49. PubMed ID: 5340142
    [No Abstract]   [Full Text] [Related]  

  • 47. [Simulation of stent treatment for aneurysms in the inner bend of aortic arch].
    Qiao A; Liu Y; Zhang S
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Aug; 24(4):852-6, 869. PubMed ID: 17899759
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Analysis of pulsatile blood flow in constricted bifurcated arteries with vorticity-stream function approach.
    Chakravarty S; Sen S
    J Med Eng Technol; 2008; 32(1):10-22. PubMed ID: 18183516
    [TBL] [Abstract][Full Text] [Related]  

  • 49. 3D flow study in a mildly stenotic coronary artery phantom using a whole volume PIV method.
    Brunette J; Mongrain R; Laurier J; Galaz R; Tardif JC
    Med Eng Phys; 2008 Nov; 30(9):1193-200. PubMed ID: 18406195
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Medical application oriented blood flow simulation.
    Qiao A; Liu Y
    Clin Biomech (Bristol, Avon); 2008; 23 Suppl 1():S130-6. PubMed ID: 18023946
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Modeling rough stenoses by an immersed-boundary method.
    Yakhot A; Grinberg L; Nikitin N
    J Biomech; 2005 May; 38(5):1115-27. PubMed ID: 15797593
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Initial results after combined repair of aortic arch aneurysms by sequential transposition of the supra-aortic branches and consecutive endovascular stent-graft placement.
    Czerny M; Zimpfer D; Fleck T; Hofmann W; Schoder M; Cejna M; Stampfl P; Lammer J; Wolner E; Grabenwoger M
    Ann Thorac Surg; 2004 Oct; 78(4):1256-60. PubMed ID: 15464481
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Numerical simulation of hemodynamics in the ascending aorta induced by different aortic cannulas.
    Stühle S; Wendt D; Jakob H; Kowalczyk W
    Minim Invasive Ther Allied Technol; 2011 Apr; 20(2):125-31. PubMed ID: 21417846
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Validation of a fluid-structure interaction numerical model for predicting flow transients in arteries.
    Kanyanta V; Ivankovic A; Karac A
    J Biomech; 2009 Aug; 42(11):1705-12. PubMed ID: 19482285
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Analysis of Dynamic Geometric Configuration of the Aortic Channel from the Perspective of Tornado-Like Flow Organization of Blood Flow.
    Zhorzholiani ST; Mironov AA; Talygin EA; Tsyganokov YM; Agafonov AM; Kiknadze GI; Gorodkov AY; Bokeriya LA
    Bull Exp Biol Med; 2018 Mar; 164(4):514-518. PubMed ID: 29504108
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Comparison of the hemodynamics in 6mm and 4-7 mm hemodialysis grafts by means of CFD.
    Van Tricht I; De Wachter D; Tordoir J; Verdonck P
    J Biomech; 2006; 39(2):226-36. PubMed ID: 16321624
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Unsteady simulation of distal blood flow in an end-to-side anastomosed coronary bypass graft with stenosis.
    Najarian S; Dargahi J; Firouzi F; Afsari J
    Biomed Mater Eng; 2006; 16(5):337-47. PubMed ID: 17075169
    [TBL] [Abstract][Full Text] [Related]  

  • 58. The impact of aortic arch geometry on flow dynamics using a simplified approach with magnetic resonance velocity mapping.
    Fogel MA; Weinberg PM; Haselgrove J
    Congenit Heart Dis; 2006 Nov; 1(6):300-8. PubMed ID: 18377498
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Characterization of Hemodynamics in Great Arteries of Wild-Type Mouse Using Computational Fluid Dynamics Based on Ultrasound Images.
    Chen Z; Zhou Y; Ma Y; Wang J; He Y; Li Z
    Ultrasound Q; 2016 Mar; 32(1):51-7. PubMed ID: 26938034
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Computational analysis of hybrid Norwood circulation with distal aortic arch obstruction and reverse Blalock-Taussig shunt.
    Ceballos A; Argueta-Morales IR; Divo E; Osorio R; Caldarone CA; Kassab AJ; Decampli WM
    Ann Thorac Surg; 2012 Nov; 94(5):1540-50. PubMed ID: 22981256
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.