204 related articles for article (PubMed ID: 15234503)
1. Kirschner wire pin tract infection rates: a randomized controlled trial between percutaneous and buried wires.
Hargreaves DG; Drew SJ; Eckersley R
J Hand Surg Br; 2004 Aug; 29(4):374-6. PubMed ID: 15234503
[TBL] [Abstract][Full Text] [Related]
2. Kirschner wire pin tract infection rates between percutaneous and buried wires in treating metacarpal and phalangeal fractures.
Rafique A; Ghani S; Sadiq M; Siddiqui IA
J Coll Physicians Surg Pak; 2006 Aug; 16(8):518-20. PubMed ID: 16899179
[TBL] [Abstract][Full Text] [Related]
3. Complications of Kirschner-wire fixation in distal radius fractures.
Subramanian P; Kantharuban S; Shilston S; Pearce OJ
Tech Hand Up Extrem Surg; 2012 Sep; 16(3):120-3. PubMed ID: 22913989
[TBL] [Abstract][Full Text] [Related]
4. Infection rate of percutaneous Kirschner wire fixation for distal radius fractures.
Lakshmanan P; Dixit V; Reed MR; Sher JL
J Orthop Surg (Hong Kong); 2010 Apr; 18(1):85-6. PubMed ID: 20427842
[TBL] [Abstract][Full Text] [Related]
5. Discharging pin sites following K-wire fixation of distal radial fractures: a case for pin removal?
Desai A; Dramis A; Thompson N; Board T; Choudhary A
Acta Orthop Belg; 2009 Jun; 75(3):310-5. PubMed ID: 19681315
[TBL] [Abstract][Full Text] [Related]
6. Incidence of Treatment for Infection of Buried Versus Exposed Kirschner Wires in Phalangeal, Metacarpal, and Distal Radial Fractures.
Ridley TJ; Freking W; Erickson LO; Ward CM
J Hand Surg Am; 2017 Jul; 42(7):525-531. PubMed ID: 28465016
[TBL] [Abstract][Full Text] [Related]
7. Percutaneous pinning of distal radius fractures: an anatomic study demonstrating the proximity of K-wires to structures at risk.
Chia B; Catalano LW; Glickel SZ; Barron OA; Meier K
J Hand Surg Am; 2009; 34(6):1014-20. PubMed ID: 19643288
[TBL] [Abstract][Full Text] [Related]
8. Complications associated with distraction plate fixation of wrist fractures.
Hanel DP; Ruhlman SD; Katolik LI; Allan CH
Hand Clin; 2010 May; 26(2):237-43. PubMed ID: 20494750
[TBL] [Abstract][Full Text] [Related]
9. Implant removal on an outpatient basis. A patient satisfaction survey.
Moholkar K; Lodhi Y; Corrigan J
Acta Orthop Belg; 2003 Dec; 69(6):507-9. PubMed ID: 14748105
[TBL] [Abstract][Full Text] [Related]
10. [Bore wire osteosynthesis in distal radius fracture].
Knigge-Barrios H; Rudolph H
Aktuelle Traumatol; 1987 Jun; 17(3):105-8. PubMed ID: 2888272
[TBL] [Abstract][Full Text] [Related]
11. [Kirschner wire osteosynthesis for fractures in childhood: bury wires or not? : Results of a survey on care reality in Germany].
Schneidmueller D; Kertai M; Bühren V; von Rüden C
Unfallchirurg; 2018 Oct; 121(10):817-824. PubMed ID: 29464293
[TBL] [Abstract][Full Text] [Related]
12. Superficial radial nerve damage due to Kirschner wiring of the radius.
Singh S; Trikha P; Twyman R
Injury; 2005 Feb; 36(2):330-2. PubMed ID: 15664599
[TBL] [Abstract][Full Text] [Related]
13. [Manipulative reduction and closed thread a Kirschner wire for the treatment of comminuted fracture of distal radius in middle-aged and senile patients].
Ke Y; Pan ZX; He JX
Zhongguo Gu Shang; 2009 Oct; 22(10):761-2. PubMed ID: 19902756
[No Abstract] [Full Text] [Related]
14. A randomized, controlled trial of distal radius fractures with metaphyseal displacement but without joint incongruity: closed reduction and casting versus closed reduction, spanning external fixation, and optional percutaneous K-wires.
Kreder HJ; Agel J; McKee MD; Schemitsch EH; Stephen D; Hanel DP
J Orthop Trauma; 2006 Feb; 20(2):115-21. PubMed ID: 16462564
[TBL] [Abstract][Full Text] [Related]
15. Infection after buried or exposed K-wire fixation of distal radial fractures: a randomized clinical trial.
Maradei-Pereira JAR; Dos Santos AP; Martins JR; Maradei-Pereira MR
J Hand Surg Eur Vol; 2021 Feb; 46(2):154-158. PubMed ID: 32611274
[TBL] [Abstract][Full Text] [Related]
16. Infection rates following perioperative prophylactic antibiotics versus postoperative extended regimen prophylactic antibiotics in surgical management of mandibular fractures.
Lovato C; Wagner JD
J Oral Maxillofac Surg; 2009 Apr; 67(4):827-32. PubMed ID: 19304041
[TBL] [Abstract][Full Text] [Related]
17. Fractures of the distal radius treated with a nonbridging external fixation technique using multiplanar k-wires.
Gradl G; Jupiter JB; Gierer P; Mittlmeier T
J Hand Surg Am; 2005 Sep; 30(5):960-8. PubMed ID: 16182052
[TBL] [Abstract][Full Text] [Related]
18. Displaced distal end radius fractures in children treated with Kirschner wires - A systematic review.
Khandekar S; Tolessa E; Jones S
Acta Orthop Belg; 2016 Dec; 82(4):681-689. PubMed ID: 29182107
[TBL] [Abstract][Full Text] [Related]
19. Is the use of arch bars or interdental wire fixation necessary for successful outcomes in the open reduction and internal fixation of mandibular angle fractures?
Bell RB; Wilson DM
J Oral Maxillofac Surg; 2008 Oct; 66(10):2116-22. PubMed ID: 18848111
[TBL] [Abstract][Full Text] [Related]
20. Should we bury K-wires after metacarpal and phalangeal fracture osteosynthesis?
Terndrup M; Jensen T; Kring S; Lindberg-Larsen M
Injury; 2018 Jun; 49(6):1126-1130. PubMed ID: 29602487
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]