These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 15235206)

  • 1. A new technique of fixation of radial head fractures using a modified tubular plate.
    Guha AR; Jago ER
    J Postgrad Med; 2004; 50(2):113-4. PubMed ID: 15235206
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Internal fixation of radial shaft fractures: Anatomical and biomechanical principles].
    Bartoníček J; Naňka O; Tuček M
    Rozhl Chir; 2015 Oct; 94(10):425-36. PubMed ID: 26556020
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The long-term outcome of open reduction and internal fixation of stable displaced isolated partial articular fractures of the radial head.
    Lindenhovius AL; Felsch Q; Ring D; Kloen P
    J Trauma; 2009 Jul; 67(1):143-6. PubMed ID: 19590324
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical stability of different fixation constructs for ORIF of radial neck fractures.
    Capo JT; Svach D; Ahsgar J; Orillaza NS; Sabatino CT
    Orthopedics; 2008 Oct; 31(10):. PubMed ID: 19226014
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanics and biology of plate fixation of distal radius fractures.
    Freeland AE; Luber KT
    Hand Clin; 2005 Aug; 21(3):329-39. PubMed ID: 16039444
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Operative treatment of a fractured head of the radius with a modified 3-hole-plate (author's transl)].
    Persch WF
    Unfallheilkunde; 1981 Nov; 84(11):480-1. PubMed ID: 7314304
    [No Abstract]   [Full Text] [Related]  

  • 7. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
    Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
    J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model.
    Grindel SI; Wang M; Gerlach M; McGrady LM; Brown S
    J Hand Surg Am; 2007 Feb; 32(2):194-9. PubMed ID: 17275594
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison between open reduction internal fixation with kirschner nails and mini-plates in treatment of Mason type II and III fractures of radial head: a case-control study].
    Zhao Y; Zhu XJ; Song NY; Pan KL
    Zhongguo Gu Shang; 2012 Apr; 25(4):310-2. PubMed ID: 22812096
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures.
    Wolf JC; Weil WM; Hanel DP; Trumble TE
    J Hand Surg Am; 2006 Dec; 31(10):1578-86. PubMed ID: 17145376
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Capitellar cartilage injuries concomitant with radial head fractures.
    Nalbantoglu U; Gereli A; Kocaoglu B; Aktas S; Turkmen M
    J Hand Surg Am; 2008 Nov; 33(9):1602-7. PubMed ID: 18984344
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction--a biomechanic study in a cadaveric model.
    Drobetz H; Bryant AL; Pokorny T; Spitaler R; Leixnering M; Jupiter JB
    J Hand Surg Am; 2006 Apr; 31(4):615-22. PubMed ID: 16632057
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dorsal double-plate fixation of the distal radius.
    Rikli DA; Businger A; Babst R
    Oper Orthop Traumatol; 2005 Dec; 17(6):624-40. PubMed ID: 16369757
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radial head fractures: operative or conservative treatment? The Greek temple model.
    Hammacher ER; van der Werken C
    Acta Orthop Belg; 1996; 62 Suppl 1():112-5. PubMed ID: 9084564
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Two potential causes of EPL rupture after distal radius volar plate fixation.
    Benson EC; DeCarvalho A; Mikola EA; Veitch JM; Moneim MS
    Clin Orthop Relat Res; 2006 Oct; 451():218-22. PubMed ID: 16770281
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Plate presetting arthroscopic reduction technique for the distal radius fractures.
    Abe Y; Tsubone T; Tominaga Y
    Tech Hand Up Extrem Surg; 2008 Sep; 12(3):136-43. PubMed ID: 18776773
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius.
    Imatani J; Noda T; Morito Y; Sato T; Hashizume H; Inoue H
    J Hand Surg Br; 2005 May; 30(2):220-5. PubMed ID: 15757779
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Flexor tendon injuries following locked volar plating of distal radius fractures.
    Cross AW; Schmidt CC
    J Hand Surg Am; 2008 Feb; 33(2):164-7. PubMed ID: 18294535
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anatomy of the posterior interosseous nerve in relation to fixation of the radial head.
    Tornetta P; Hochwald N; Bono C; Grossman M
    Clin Orthop Relat Res; 1997 Dec; (345):215-8. PubMed ID: 9418643
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of an additional locking screw on fracture reduction after volar fixed-angle plating-introduction of the "protection screw" in an extra-articular distal radius fracture model.
    Weninger P; Schueller M; Drobetz H; Jamek M; Redl H; Tschegg E
    J Trauma; 2009 Oct; 67(4):746-51. PubMed ID: 19820581
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.