  • 1. Dose calcium balanced heparin affect blood gas and electrolyte analysis?
    Ochiai R; Nagano M
    J Anesth; 1990 Jan; 4(1):61-5. PubMed ID: 15236018
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Different manufacturers of syringes: a new source of variability in blood gas, acid-base balance and related laboratory test?
    Lima-Oliveira G; Lippi G; Salvagno GL; Montagnana M; Picheth G; Guidi GC
    Clin Biochem; 2012 Jun; 45(9):683-7. PubMed ID: 22440459
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrolyte-balanced heparin in blood gas syringes can introduce a significant bias in the measurement of positively charged electrolytes.
    van Berkel M; Scharnhorst V
    Clin Chem Lab Med; 2011 Feb; 49(2):249-52. PubMed ID: 21143021
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of ionized calcium in canine blood samples collected in prefilled and self-filled heparinized syringes using the i-STAT point-of-care analyzer.
    Tappin S; Rizzo F; Dodkin S; Papasouliotis K; Tasker S; Murphy K
    Vet Clin Pathol; 2008 Mar; 37(1):66-72. PubMed ID: 18366547
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dry electrolyte-balanced heparinized syringes evaluated for determining ionized calcium and other electrolytes in whole blood.
    Toffaletti J; Ernst P; Hunt P; Abrams B
    Clin Chem; 1991 Oct; 37(10 Pt 1):1730-3. PubMed ID: 1914173
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Is liquid heparin comparable to dry balanced heparin for blood gas sampling in intensive care unit?
    Chhapola V; Kumar S; Goyal P
    Indian J Crit Care Med; 2014 Jan; 18(1):14-20. PubMed ID: 24550608
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of liquid heparin for blood gas sampling in pediatric intensive care unit: A comparative study of effects of varying volumes of heparin on blood gas parameters.
    Chhapola V; Kumar S; Goyal P; Sharma R
    Indian J Crit Care Med; 2013 Nov; 17(6):350-4. PubMed ID: 24501486
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Relationship between free hemoglobin (hemolysis), potassium and ionized calcium in lithium heparin blood gas samples collected intraoperatively.
    Summerfield DD; Hartung KJ; Wiese CR; Wockenfus AM; Katzman BM; Donato LJ; Karon BS
    Clin Biochem; 2019 Aug; 70():46-48. PubMed ID: 31059687
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of blood gas and electrolyte test results from the Gem-Stat and CDI-300 versus a conventional laboratory analyzer.
    Walton HG; Duvall TB; Van den Hout J; Boucher DM
    J Extra Corpor Technol; 1993; 25(2):53-7. PubMed ID: 10171685
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of different forms of heparin on point-of-care blood gas analysis.
    Sandler P; Goldstein LN
    S Afr Med J; 2018 Feb; 108(3):224-229. PubMed ID: 30004367
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The effect of dilution and heparin on the blood gas analysis].
    Jiang HX
    Zhonghua Jie He He Hu Xi Za Zhi; 1992 Aug; 15(4):225-7, 255-6. PubMed ID: 1307518
    [TBL] [Abstract][Full Text] [Related]  

  • 12. IFCC recommendation on sampling, transport and storage for the determination of the concentration of ionized calcium in whole blood, plasma and serum.
    Boink AB; Buckley BM; Christiansen TF; Covington AK; Maas AH; Müller-Plathe O; Sachs C; Siggaard-Andersen O
    J Automat Chem; 1991; 13(5):235-9. PubMed ID: 18924910
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Heparinization of blood decreases ionized calcium concentration.
    Soong WJ; Wang HZ; Hwang B
    Zhonghua Yi Xue Za Zhi (Taipei); 1991 May; 47(5):331-5. PubMed ID: 1649675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Liquid heparin anticoagulant produces more negative bias in the determination of ionized magnesium than ionized calcium.
    Shin CS; Chang CH; Kim JH
    Yonsei Med J; 2006 Apr; 47(2):191-5. PubMed ID: 16642547
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preanalytical variables in measurement of free (ionized) calcium in lithium heparin-containing blood collection tubes.
    Haverstick DM; Brill LB; Scott MG; Bruns DE
    Clin Chim Acta; 2009 May; 403(1-2):102-4. PubMed ID: 19361462
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of syringes for ionized calcium measurements.
    Sachs C; Rabouine P; Dautzenberg MD
    Scand J Clin Lab Invest Suppl; 1996; 224():193-201. PubMed ID: 8865436
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of blood gas, electrolyte and metabolite results measured with two different blood gas analyzers and a core laboratory analyzer.
    Uyanik M; Sertoglu E; Kayadibi H; Tapan S; Serdar MA; Bilgi C; Kurt I
    Scand J Clin Lab Invest; 2015 Apr; 75(2):97-105. PubMed ID: 25431133
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Heparin Concentration in Evacuated Tubes and Its Effect on pH, Ionized Calcium, Lactate, and Potassium in Venous Blood Gas Analysis.
    Mahler K; Kerlin R; Jones J; Li J
    Lab Med; 2023 Sep; 54(5):e157-e160. PubMed ID: 37095624
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Factors affecting the determination of ionized calcium in blood.
    Brauman J; Delvigne C; Deconinck I; Willems D
    Scand J Clin Lab Invest Suppl; 1983; 165():27-31. PubMed ID: 6578571
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.
    Steinfelder-Visscher J; Weerwind PW; Teerenstra S; Brouwer MH
    Perfusion; 2006 Jan; 21(1):33-7. PubMed ID: 16485697
    [TBL] [Abstract][Full Text] [Related]  