These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 15236061)

  • 21. Airflow resistance of airflow-regulating devices described by independent coefficients.
    Verkerke GJ; Geertsema AA; Schutte HK
    Ann Otol Rhinol Laryngol; 2001 Jul; 110(7 Pt 1):639-45. PubMed ID: 11465823
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Heat and moisture exchanger used in a cardiothoracic surgery intensive care unit: Airway resistance and changing interval.
    Liu H; Wang H; Mu Z; Ye L; Jiang Y
    Turk Gogus Kalp Damar Cerrahisi Derg; 2020 Oct; 28(4):593-600. PubMed ID: 33403131
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Heat and moisture exchanger: importance of humidification in anaesthesia and ventilatory breathing system.
    Parmar V
    J Indian Med Assoc; 2008 Aug; 106(8):533-5, 537. PubMed ID: 18975515
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
    Campbell RS; Davis K; Johannigman JA; Branson RD
    Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.
    Brusasco C; Corradi F; Vargas M; Bona M; Bruno F; Marsili M; Simonassi F; Santori G; Severgnini P; Kacmarek RM; Pelosi P
    Respir Care; 2013 Nov; 58(11):1878-85. PubMed ID: 23674812
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of resistance in 8 different heat-and-moisture exchangers: effects of saturation and flow rate/profile.
    Lucato JJ; Tucci MR; Schettino GP; Adams AB; Fu C; Forti G; de Carvalho CR; de Souza R
    Respir Care; 2005 May; 50(5):636-43. PubMed ID: 15871758
    [TBL] [Abstract][Full Text] [Related]  

  • 27. In vitro and in vivo evaluation of a new active heat moisture exchanger.
    Chiumello D; Pelosi P; Park G; Candiani A; Bottino N; Storelli E; Severgnini P; D'Onofrio D; Gattinoni L; Chiaranda M
    Crit Care; 2004 Oct; 8(5):R281-8. PubMed ID: 15469569
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Measurement of the humidity of inspired air in ventilated patients with various humidifer systems].
    Christiansen S; Renzing K; Hirche H; Reidemeister JC
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 May; 33(5):300-5. PubMed ID: 9645289
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.
    Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD
    Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia.
    Boots RJ; George N; Faoagali JL; Druery J; Dean K; Heller RF
    Crit Care Med; 2006 Mar; 34(3):687-93. PubMed ID: 16505654
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Assessment of tracheal temperature and humidity in laryngectomized individuals and the influence of a heat and moisture exchanger on tracheal climate.
    Zuur JK; Muller SH; Vincent A; Sinaasappel M; de Jongh FH; Hilgers FJ
    Head Neck; 2008 Aug; 30(8):1072-82. PubMed ID: 18528903
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week.
    Ricard JD; Le Mière E; Markowicz P; Lasry S; Saumon G; Djedaïni K; Coste F; Dreyfuss D
    Am J Respir Crit Care Med; 2000 Jan; 161(1):104-9. PubMed ID: 10619805
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia.
    Djedaini K; Billiard M; Mier L; Le Bourdelles G; Brun P; Markowicz P; Estagnasie P; Coste F; Boussougant Y; Dreyfuss D
    Am J Respir Crit Care Med; 1995 Nov; 152(5 Pt 1):1562-9. PubMed ID: 7582295
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 - practical use, including problems, and their use with paediatric patients.
    Wilkes AR
    Anaesthesia; 2011 Jan; 66(1):40-51. PubMed ID: 21118189
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Is the lithium chloride-coated heat and moisture exchanger a danger for patients?].
    Rathgeber J; Zielmann S; Kietzmann D; Züchner K; Warnecke G
    Anaesthesist; 1992 Apr; 41(4):204-7. PubMed ID: 1317137
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Value of HME antibacterial filters in neonatal and pediatric anesthesia. Comparison with traditional heating humidifiers].
    Runti G; Bertuzzi C; Scarpa R
    Cah Anesthesiol; 1994; 42(2):153-7. PubMed ID: 8087629
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Ventilator-associated pneumonia using a heated humidifier or a heat and moisture exchanger: a randomized controlled trial [ISRCTN88724583].
    Lorente L; Lecuona M; Jiménez A; Mora ML; Sierra A
    Crit Care; 2006; 10(4):R116. PubMed ID: 16884530
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Short-term endotracheal climate changes and clinical effects of a heat and moisture exchanger with an integrated electrostatic virus and bacterial filter developed for laryngectomized individuals.
    Scheenstra RJ; Muller SH; Vincent A; Ackerstaff AH; Jacobi I; Hilgers FJ
    Acta Otolaryngol; 2010 Jun; 130(6):739-46. PubMed ID: 20001445
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Respiratory mechanics of neurological patients undergoing mechanical ventilation under water heated humidifier and a heat exchanger filter model.
    Siqueira TB; Costa JC; Tavares IC; Torres PM; Andrade Mdo A; França EÉ; Galindo Filho VC; Andrade FM
    Rev Bras Ter Intensiva; 2010 Sep; 22(3):264-9. PubMed ID: 25302433
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Heat and moisture exchanger use reduces in-hospital complications following total laryngectomy: a case-control study.
    Foreman A; De Santis RJ; Sultanov F; Enepekides DJ; Higgins KM
    J Otolaryngol Head Neck Surg; 2016 Jul; 45(1):40. PubMed ID: 27389086
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.