These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
88 related articles for article (PubMed ID: 15239566)
1. Modelling the bioelectric behaviour of halo pin-patient structures during magnetic resonance imaging. Saari A; Runciman RJ; Hayward G Proc Inst Mech Eng H; 2004; 218(3):159-65. PubMed ID: 15239566 [TBL] [Abstract][Full Text] [Related]
2. A cadaveric simulation of distal femoral traction shows safety in magnetic resonance imaging. Mansour A; Block J; Obremskey W J Orthop Trauma; 2009 Oct; 23(9):658-62. PubMed ID: 19897988 [TBL] [Abstract][Full Text] [Related]
3. Design and initial testing of a novel halo orthosis. Woodcox BA; Stamper RE Biomed Sci Instrum; 2003; 39():266-71. PubMed ID: 12724905 [TBL] [Abstract][Full Text] [Related]
4. A comparison of various angles of halo pin insertion in an immature skull model. Copley LA; Pepe MD; Tan V; Sheth N; Dormans JP Spine (Phila Pa 1976); 1999 Sep; 24(17):1777-80. PubMed ID: 10488506 [TBL] [Abstract][Full Text] [Related]
5. Investigation of how different halos influence pin forces. Kerwin GA; Chou KL; White DB; Shen KL; Salciccioli GG; Yang KH Spine (Phila Pa 1976); 1994 May; 19(9):1078-81. PubMed ID: 8029746 [TBL] [Abstract][Full Text] [Related]
6. The force exerted by the halo pin. A study comparing different halo systems. Whitesides TE; Mehserle WL; Hutton WC Spine (Phila Pa 1976); 1992 Oct; 17(10 Suppl):S413-7. PubMed ID: 1440036 [TBL] [Abstract][Full Text] [Related]
7. The effect of pin location on the rigidity of the halo pin-bone interface. Ballock RT; Lee TQ; Triggs KJ; Woo SL; Garfin SR Neurosurgery; 1990 Feb; 26(2):238-41. PubMed ID: 2308671 [TBL] [Abstract][Full Text] [Related]
8. A new method of tightening halo orthosis pins that reduces initial pin force variation. Klingenberg J; Keown A; Moser D; Neal T; Stamper R Biomed Sci Instrum; 2002; 38():245-50. PubMed ID: 12085610 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of skull thickness and insertion torque at the halo pin insertion areas in the elderly: a cadaveric study. Ebraheim NA; Liu J; Patil V; Sanford CG; Crotty MJ; Haman SP; Yeasting RA Spine J; 2007; 7(6):689-93. PubMed ID: 17998128 [TBL] [Abstract][Full Text] [Related]
10. Mechanical evaluation of four- versus eight-pin halo fixation. Letts M; Girouard L; Yeadon A J Pediatr Orthop; 1997; 17(1):121-4. PubMed ID: 8989714 [TBL] [Abstract][Full Text] [Related]
11. A comparative evaluation of halo pin designs in an immature skull model. Copley LA; Pepe MD; Tan V; Dormans JP; Gabriel JP; Sheth NP; Asada N Clin Orthop Relat Res; 1998 Dec; (357):212-8. PubMed ID: 9917719 [TBL] [Abstract][Full Text] [Related]
12. Osteology of the pediatric skull. Considerations of halo pin placement. Wong WB; Haynes RJ Spine (Phila Pa 1976); 1994 Jul; 19(13):1451-4. PubMed ID: 7939973 [TBL] [Abstract][Full Text] [Related]
13. Halo pin insertion-associated brain abscess: case report and review of literature. Saeed MU; Dacuycuy MA; Kennedy DJ Spine (Phila Pa 1976); 2007 Apr; 32(8):E271-4. PubMed ID: 17426624 [TBL] [Abstract][Full Text] [Related]
14. Stress analysis of halo pin insertion by non-linear finite element modeling. Voor MJ; Anderson RC; Hart RT J Biomech; 1997 Sep; 30(9):903-9. PubMed ID: 9302613 [TBL] [Abstract][Full Text] [Related]
15. Analysis of pin force distributions of halo orthoses. Kuester WM; Stamper RE; Ordway NR Biomed Sci Instrum; 2002; 38():221-6. PubMed ID: 12085606 [TBL] [Abstract][Full Text] [Related]
16. Low profile halo head fixation in non-human primates. Azimi K; Prescott IA; Marino RA; Winterborn A; Levy R J Neurosci Methods; 2016 Aug; 268():23-30. PubMed ID: 27132241 [TBL] [Abstract][Full Text] [Related]
17. Transient brain injury from penetration of a halo pin. Pande K; Basu S; Webb JK Spinal Cord; 1998 Oct; 36(10):732-3. PubMed ID: 9800277 [TBL] [Abstract][Full Text] [Related]
18. Analysis of patients with nonambulatory neuromuscular scoliosis surgically treated to the pelvis with intraoperative halo-femoral traction. Takeshita K; Lenke LG; Bridwell KH; Kim YJ; Sides B; Hensley M Spine (Phila Pa 1976); 2006 Sep; 31(20):2381-5. PubMed ID: 16985468 [TBL] [Abstract][Full Text] [Related]
19. Halo pin positioning in the temporal bone; parameters for safe halo gravity traction. Semmelink K; Hekman EEG; van Griethuysen M; Bosma J; Swaan A; Kruyt MC Spine Deform; 2021 Jan; 9(1):255-261. PubMed ID: 32915397 [TBL] [Abstract][Full Text] [Related]