21. MR safety assessment of potential RF heating from cranial fixation plates at 7 T. Kraff O; Wrede KH; Schoemberg T; Dammann P; Noureddine Y; Orzada S; Ladd ME; Bitz AK Med Phys; 2013 Apr; 40(4):042302. PubMed ID: 23556915 [TBL] [Abstract][Full Text] [Related]
22. Biomechanical evaluation of fetal calf skull as a model for testing halo-pin designs for use in children. Beall MS; Copley LA; Niemann JJ; Lankachandra K; Williams JL J Biomech; 2007; 40(5):1137-44. PubMed ID: 16797557 [TBL] [Abstract][Full Text] [Related]
23. Monitoring the use of halo fixation device through an assessment form. Ho CH; Li KK; Chin RP; Lee HW; Kwong WY; Kwan HH J Orthop Surg (Hong Kong); 2011 Dec; 19(3):322-5. PubMed ID: 22184163 [TBL] [Abstract][Full Text] [Related]
30. Anterior cruciate ligament reconstruction by using bioabsorbable femoral cross pins: MR imaging findings at follow-up and comparison with clinical findings. Studler U; White LM; Naraghi AM; Tomlinson G; Kunz M; Kahn G; Marks P Radiology; 2010 Apr; 255(1):108-16. PubMed ID: 20308449 [TBL] [Abstract][Full Text] [Related]
31. Complications of halo use in children. Limpaphayom N; Skaggs DL; McComb G; Krieger M; Tolo VT Spine (Phila Pa 1976); 2009 Apr; 34(8):779-84. PubMed ID: 19337133 [TBL] [Abstract][Full Text] [Related]
32. [Development of an magnetic resonance imaging safety management system for metallic biomedical products using an magnetic resonance compatibility database and inquiry-based patient records]. Fujiwara Y; Kata T; Fujimoto S; Yachida T; Kanamoto M; Nanbu Y; Seki K; Kosaka N; Kimura H; Adachi T Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Dec; 70(12):1413-9. PubMed ID: 25672446 [TBL] [Abstract][Full Text] [Related]
33. Intracranial penetration of a halo pin causing an epileptic seizure. Kingma R; Peters JM; Coene LN J Bone Joint Surg Br; 2006 Dec; 88(12):1654-5. PubMed ID: 17159182 [TBL] [Abstract][Full Text] [Related]
34. External fixator pin design. Halsey D; Fleming B; Pope MH; Krag M; Kristiansen T Clin Orthop Relat Res; 1992 May; (278):305-12. PubMed ID: 1563166 [TBL] [Abstract][Full Text] [Related]
35. Magnetic resonance compatibility of multichannel silicon microelectrode systems for neural recording and stimulation: design criteria, tests, and recommendations. Martínez Santiesteban FM; Swanson SD; Noll DC; Anderson DJ IEEE Trans Biomed Eng; 2006 Mar; 53(3):547-58. PubMed ID: 16532782 [TBL] [Abstract][Full Text] [Related]
36. Does routine pin re-torquing of patients wearing a halo-thoracic orthosis reduce the need for pin replacement? Fraser S; Coffey JP Prosthet Orthot Int; 2015 Aug; 39(4):338-41. PubMed ID: 24812117 [TBL] [Abstract][Full Text] [Related]