233 related articles for article (PubMed ID: 15240060)
1. Corrosion resistance of iron-platinum magnets.
Yiu EY; Fang DT; Chu FC; Chow TW
J Dent; 2004 Aug; 32(6):423-9. PubMed ID: 15240060
[TBL] [Abstract][Full Text] [Related]
2. Magnetic strength and corrosion of rare earth magnets.
Ahmad KA; Drummond JL; Graber T; BeGole E
Am J Orthod Dentofacial Orthop; 2006 Sep; 130(3):275.e11-5. PubMed ID: 16979482
[TBL] [Abstract][Full Text] [Related]
3. [The effects of pH in artificial saliva on the corrosion resistance of magnetic retainers].
Hu B; Zhang F; Zheng Y
Hua Xi Kou Qiang Yi Xue Za Zhi; 2003 Aug; 21(4):301-3. PubMed ID: 14513590
[TBL] [Abstract][Full Text] [Related]
4. Investigations into the failure of dental magnets.
Riley MA; Williams AJ; Speight JD; Walmsley AD; Harris IR
Int J Prosthodont; 1999; 12(3):249-54. PubMed ID: 10635193
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of the attractive force of different types of new-generation magnetic attachment systems.
Akin H; Coskun ME; Akin EG; Ozdemir AK
J Prosthet Dent; 2011 Mar; 105(3):203-7. PubMed ID: 21356413
[TBL] [Abstract][Full Text] [Related]
6. An in vitro study into the corrosion of intra-oral magnets in the presence of dental amalgam.
Noar JH; Evans RD; Wilson D; Costello J; Ioannou E; Ayeni A; Mordan NJ; Wilson M; Pratten J
Eur J Orthod; 2003 Dec; 25(6):615-9. PubMed ID: 14700268
[TBL] [Abstract][Full Text] [Related]
7. In vitro cytotoxicity testing of neodymium-iron-boron magnets.
Donohue VE; McDonald F; Evans R
J Appl Biomater; 1995; 6(1):69-74. PubMed ID: 7703540
[TBL] [Abstract][Full Text] [Related]
8. Effect of corrosion products (neodymium iron boron) on oral fibroblast proliferation.
Evans RD; McDonald F
J Appl Biomater; 1995; 6(3):199-202. PubMed ID: 7492811
[TBL] [Abstract][Full Text] [Related]
9. [An evaluation on corrosion resistance of magnetic retainers].
Zhang F; Hu B; Zheng Y
Zhonghua Kou Qiang Yi Xue Za Zhi; 2001 Jul; 36(4):295-7. PubMed ID: 11718015
[TBL] [Abstract][Full Text] [Related]
10. Breakaway forces of flat and domed surfaced Magfit implant magnet attachments.
Chopra V; Smith BJ; Preiskel HW; Palmer RM; Curtis R
Eur J Prosthodont Restor Dent; 2007 Mar; 15(1):7-12. PubMed ID: 17378452
[TBL] [Abstract][Full Text] [Related]
11. [Sandwich type dental magnetic devices of Nd-Fe-B magnet and permendur].
Okuno O; Nakano T; Hamanaka H; Kinouchi Y
Shika Zairyo Kikai; 1989 Jul; 8(4):539-45. PubMed ID: 2491164
[TBL] [Abstract][Full Text] [Related]
12. The corrosion behavior of Nd2Fe14B and SmCo5 magnets.
Kitsugi A; Okuno O; Nakano T; Hamanaka H; Kuroda T
Dent Mater J; 1992 Dec; 11(2):119-29. PubMed ID: 1304968
[TBL] [Abstract][Full Text] [Related]
13. The durability of parylene coatings on neodymium-iron-boron magnets.
Noar JH; Wahab A; Evans RD; Wojcik AG
Eur J Orthod; 1999 Dec; 21(6):685-93. PubMed ID: 10665198
[TBL] [Abstract][Full Text] [Related]
14. In vitro corrosion behavior of cast iron-platinum magnetic alloys.
Watanabe I; Hai K; Tanaka Y; Hisatsune K; Atsuta M
Dent Mater; 2001 May; 17(3):217-20. PubMed ID: 11257294
[TBL] [Abstract][Full Text] [Related]
15. Interference of neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators: an in vitro study.
Ryf S; Wolber T; Duru F; Luechinger R
Technol Health Care; 2008; 16(1):13-8. PubMed ID: 18334784
[TBL] [Abstract][Full Text] [Related]
16. The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: initial retention values.
Michelinakis G; Barclay CW; Smith PW
Int J Prosthodont; 2006; 19(5):507-12. PubMed ID: 17323731
[TBL] [Abstract][Full Text] [Related]
17. The use of a neodymium-iron-boron magnet device for positioning a multi-stranded wire retainer in lingual retention--a pilot study in humans.
Hahn W; Fricke J; Fricke-Zech S; Zapf A; Gruber R; Sadat-Khonsari R
Eur J Orthod; 2008 Oct; 30(5):433-6. PubMed ID: 18687989
[TBL] [Abstract][Full Text] [Related]
18. Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium.
Mabilleau G; Bourdon S; Joly-Guillou ML; Filmon R; Baslé MF; Chappard D
Acta Biomater; 2006 Jan; 2(1):121-9. PubMed ID: 16701867
[TBL] [Abstract][Full Text] [Related]
19. Corrosion resistance of the Pt-Fe-Nb magnets for dental-casting.
Haoka K; Kanno T; Takada Y; Kimura K; Okuno O
Dent Mater J; 2000 Sep; 19(3):270-82. PubMed ID: 11218847
[TBL] [Abstract][Full Text] [Related]
20. Corrosion resistance of three orthodontic brackets: a comparative study of three fluoride mouthwashes.
Schiff N; Dalard F; Lissac M; Morgon L; Grosgogeat B
Eur J Orthod; 2005 Dec; 27(6):541-9. PubMed ID: 16049037
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]