142 related articles for article (PubMed ID: 15241226)
1. Simple method to control a cerebrospinal fluid gusher during cochlear implant surgery.
Marks HW
Otol Neurotol; 2004 Jul; 25(4):483-4. PubMed ID: 15241226
[TBL] [Abstract][Full Text] [Related]
2. [Prediction and management about perilymph gusher in cochlear implantation].
Zhang D; Hu B; Xiao Y; Zheng H
Lin Chuang Er Bi Yan Hou Ke Za Zhi; 2006 Apr; 20(7):295-6, 299. PubMed ID: 16780140
[TBL] [Abstract][Full Text] [Related]
3. Management of cerebrospinal fluid leakage from cochleostomy during cochlear implant surgery.
Wootten CT; Backous DD; Haynes DS
Laryngoscope; 2006 Nov; 116(11):2055-9. PubMed ID: 17075411
[TBL] [Abstract][Full Text] [Related]
4. CSF gusher in cochlear implantation: The risk of missing CT evidence of a cochlear base defect in the presence of otherwise normal cochlear anatomy.
Cabbarzade C; Sennaroglu L; Süslü N
Cochlear Implants Int; 2015 Jul; 16(4):233-6. PubMed ID: 24986441
[TBL] [Abstract][Full Text] [Related]
5. [Perilymphatic gushers: myths and reality].
Ramírez Camacho R; Arellano B; García Berrocal JR
Acta Otorrinolaringol Esp; 2000 Apr; 51(3):193-8. PubMed ID: 10867391
[TBL] [Abstract][Full Text] [Related]
6. Cerebrospinal fluid gusher in cochlear implant and its associated factors.
Hashemi SB; Bozorgi H; Kazemi T; Babaei A
Acta Otolaryngol; 2020 Aug; 140(8):621-625. PubMed ID: 32329639
[No Abstract] [Full Text] [Related]
7. Enlarged Cochlear Aperture as a Risk Factor for Cerebrospinal Fluid Gusher During Cochlear Implant Surgery.
Wong K; Schwam ZG; Kaul VZ; Wanna GB
Ear Nose Throat J; 2022 Feb; 101(2):NP34-NP35. PubMed ID: 32790587
[No Abstract] [Full Text] [Related]
8. Influence of an intraoperative perilymph gusher on cochlear implant performance in children with labyrinthine malformations.
Adunka OF; Teagle HF; Zdanski CJ; Buchman CA
Otol Neurotol; 2012 Dec; 33(9):1489-96. PubMed ID: 22996156
[TBL] [Abstract][Full Text] [Related]
9. Cerebrospinal fluid gusher in cochlear implantation.
Eftekharian A; Amizadeh M
Cochlear Implants Int; 2014 May; 15(3):179-84. PubMed ID: 24660749
[TBL] [Abstract][Full Text] [Related]
10. Intraoperative seizure and cerebrospinal fluid leak during adult cochlear implant surgery.
Musser AB; Golub JS; Samy RN; Phero JC
Cochlear Implants Int; 2016; 17(2):116-9. PubMed ID: 26843205
[TBL] [Abstract][Full Text] [Related]
11. Direct measurement of cerebrospinal fluid pressure through the cochlea in a congenitally deaf child with Mondini dysplasia undergoing cochlear implantation.
Graham JM; Ashcroft P
Am J Otol; 1999 Mar; 20(2):205-8. PubMed ID: 10100524
[TBL] [Abstract][Full Text] [Related]
12. CSF Gusher in Cochlear Implant Surgery-does it affect surgical outcomes?
Vashist S; Singh S
Eur Ann Otorhinolaryngol Head Neck Dis; 2016 Jun; 133 Suppl 1():S21-4. PubMed ID: 27256962
[TBL] [Abstract][Full Text] [Related]
13. [Possible reasons for cerebrospinal fluid gusher in cochlear implantation with inner ear abnormality].
Sun SP; Lu W; Men XM; Zuo B; Lei YB
Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2017 Apr; 52(4):283-286. PubMed ID: 28441806
[No Abstract] [Full Text] [Related]
14. Incomplete electrode extraction during cochlear implant revision.
Kang SY; Zwolan TA; Kileny PR; Niparko JK; Driscoll CL; Shelton C; Telian SA
Otol Neurotol; 2009 Feb; 30(2):160-4. PubMed ID: 19180676
[TBL] [Abstract][Full Text] [Related]
15. Cochlear implantation in children with anomalous cochleovestibular anatomy.
Papsin BC
Laryngoscope; 2005 Jan; 115(1 Pt 2 Suppl 106):1-26. PubMed ID: 15626926
[TBL] [Abstract][Full Text] [Related]
16. A Novel Surgical Technique for the Management of Cerebrospinal Fluid Gusher Encountered During Cochlear Implantation.
Tolisano AM; Wick CC; Kutz JW
Otol Neurotol; 2020 Oct; 41(9):e1177. PubMed ID: 32925868
[TBL] [Abstract][Full Text] [Related]
17. Management and control of gusher during cochlear implant surgery.
Daneshi A; Farhadi M; Emamjomeh H; Hasanzadeh S
Adv Otorhinolaryngol; 2000; 57():120-2. PubMed ID: 11892123
[No Abstract] [Full Text] [Related]
18. The unilateral stapes gusher.
Rebol J
Wien Klin Wochenschr; 2004; 116 Suppl 2():90-2. PubMed ID: 15506322
[TBL] [Abstract][Full Text] [Related]
19. Surgical results of cochlear implantation in malformed cochlea.
Sennaroglu L; Sarac S; Ergin T
Otol Neurotol; 2006 Aug; 27(5):615-23. PubMed ID: 16788416
[TBL] [Abstract][Full Text] [Related]
20. Complications in cochlear implant surgery.
Gheorghe DC; Zamfir-Chiru-Anton A
J Med Life; 2015; 8(3):329-32. PubMed ID: 26351535
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]