233 related articles for article (PubMed ID: 15254880)
1. Are peristaltic pumps as reliable as syringe pumps for metabolic research? Assessment of accuracy, precision, and metabolic kinetics.
Mohammed BS; Fields DA; Mittendorfer B; Coggan AR; Klein S
Metabolism; 2004 Jul; 53(7):875-8. PubMed ID: 15254880
[TBL] [Abstract][Full Text] [Related]
2. Lag times to steady state drug delivery by continuous intravenous infusion: direct comparison of peristaltic and syringe pump performance identifies contributions from infusion system dead volume and pump startup characteristics.
Gibson LE; Knudsen AS; Arney D; Deng H; Sims NM; Peterfreund RA
J Clin Monit Comput; 2022 Oct; 36(5):1489-1498. PubMed ID: 34878612
[TBL] [Abstract][Full Text] [Related]
3. Simulation Analysis of Flow Rate Variability During Microinfusions: The Effect of Vertical Displacement and Multidrug Infusion in Conventional Infusion Pumps Versus New Cylinder-Type Infusion Pumps.
Oh EJ; Hong KY; Lee JH; Kim DK; Cho J; Min JJ
Anesth Analg; 2022 Jan; 134(1):59-68. PubMed ID: 34517393
[TBL] [Abstract][Full Text] [Related]
4. Fluid delivery from infusion-pump syringes.
Carl JL; Erstad BL; Murphy JE; Slack MK
Am J Health Syst Pharm; 1995 Jul; 52(13):1428-32. PubMed ID: 7671041
[TBL] [Abstract][Full Text] [Related]
5. Impact of syringe size on the performance of infusion pumps at low flow rates.
Schmidt N; Saez C; Seri I; Maturana A
Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
[TBL] [Abstract][Full Text] [Related]
6. A syringe pump tester.
Nieman M; Evans AL; Shaw A
J Med Eng Technol; 1986; 10(5):255-8. PubMed ID: 3783656
[TBL] [Abstract][Full Text] [Related]
7. Simulation study on flow rate accuracy of infusion pumps in vibration conditions during emergency patient transport.
Hong KY; Kim YY; Yoo SY; Lee JH; Kim DK; Min JJ
J Clin Monit Comput; 2021 Dec; 35(6):1253-1261. PubMed ID: 33159269
[TBL] [Abstract][Full Text] [Related]
8. An evaluation of intravenous infusion pumps and controllers.
Runciman WB; Ilsley AH; Rutten AJ; Baker D; Fronsko RR
Anaesth Intensive Care; 1987 May; 15(2):217-28. PubMed ID: 3605571
[TBL] [Abstract][Full Text] [Related]
9. [Factors altering low-flow drug delivery using syringe pumps: Consequences on vasoactive drug infusion in preterm infant].
Rakza T; Richard A; Lelieur AC; Villaume I; Huyghe A; Nempont C; Storme L
Arch Pediatr; 2005 May; 12(5):548-54. PubMed ID: 15885544
[TBL] [Abstract][Full Text] [Related]
10. Flow rate variability from selected syringe and mobile infusion pumps.
Farrington EA; Stull JC; Leff RD
Drug Intell Clin Pharm; 1988 Sep; 22(9):687-90. PubMed ID: 3215110
[TBL] [Abstract][Full Text] [Related]
11. [Morphine self-administration by rats using a pneumatic syringe].
Akiyama Y; Takayama S
Yakubutsu Seishin Kodo; 1988 Jun; 8(2):329-36. PubMed ID: 3218380
[TBL] [Abstract][Full Text] [Related]
12. Cost and acceptability of three syringe-pump infusion systems.
Johnson MS; Pesko LJ; Wood CF; Reinders TP
Am J Hosp Pharm; 1990 Aug; 47(8):1794-8. PubMed ID: 2389788
[TBL] [Abstract][Full Text] [Related]
13. Syringe Pump Performance Maintained with IV Filter Use During Low Flow Rate Delivery for Pediatric Patients.
Chau DF; Vasilopoulos T; Schoepf M; Zhang C; Fahy BG
Anesth Analg; 2016 Sep; 123(3):705-14. PubMed ID: 27074895
[TBL] [Abstract][Full Text] [Related]
14. [Potential advantages a new syringe pump system].
Vachon L; Dubé L; Guilleux AM; Jacob JP; Granry JC; Beydon L
Ann Fr Anesth Reanim; 2002 May; 21(5):354-8. PubMed ID: 12078426
[TBL] [Abstract][Full Text] [Related]
15. Do antisiphon valves reduce flow irregularities during vertical displacement of infusion pump systems?
Weiss M; Fischer J; Neff T; Schulz G; Bänziger O
Anaesth Intensive Care; 2000 Dec; 28(6):680-3. PubMed ID: 11153297
[TBL] [Abstract][Full Text] [Related]
16. Influence of infusion pump operation and flow rate on hemodynamic stability during epinephrine infusion.
Klem SA; Farrington JM; Leff RD
Crit Care Med; 1993 Aug; 21(8):1213-7. PubMed ID: 8339589
[TBL] [Abstract][Full Text] [Related]
17. Filling of High-Concentration Monoclonal Antibody Formulations: Investigating Underlying Mechanisms That Affect Precision of Low-Volume Fill by Peristaltic Pump.
Shieu W; Lamar D; Stauch OB; Maa YF
PDA J Pharm Sci Technol; 2016; 70(2):143-56. PubMed ID: 26797970
[TBL] [Abstract][Full Text] [Related]
18. Syringe size and flow rate affect drug delivery from syringe pumps.
Weiss M; Hug MI; Neff T; Fischer J
Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
[TBL] [Abstract][Full Text] [Related]
19. Start-up delays of infusion syringe pumps.
Neff T; Fischer J; Fehr S; Baenziger O; Weiss M
Paediatr Anaesth; 2001; 11(5):561-5. PubMed ID: 11696120
[TBL] [Abstract][Full Text] [Related]
20. Accuracy of intravenous infusion pumps in continuous renal replacement therapies.
Jenkins R; Harrison H; Chen B; Arnold D; Funk J
ASAIO J; 1992; 38(4):808-10. PubMed ID: 1450476
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]