These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 15257011)

  • 41. International sensitivity index calibration of the near-patient testing prothrombin time monitor, ProTime.
    Tripodi A; Chantarangkul V; Bressi C; Mannucci PM
    Am J Clin Pathol; 2003 Feb; 119(2):241-5. PubMed ID: 12579994
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy.
    van Geest-Daalderop JH; Mulder AB; Boonman-de Winter LJ; Hoekstra MM; van den Besselaar AM
    Clin Chem; 2005 Mar; 51(3):561-8. PubMed ID: 15650035
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Simplified Method for Local Correction of System International Normalized Ratio.
    Chandrashekar V
    Lab Med; 2017 Aug; 48(3):244-248. PubMed ID: 28934513
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A comparison between capillary and venous blood international normalized ratio determinations in a portable prothrombin time device.
    van den Besselaar AM; Meeuwisse-Braun J; Schaefer-van Mansfeld H; van Rijn C; Witteveen E
    Blood Coagul Fibrinolysis; 2000 Sep; 11(6):559-62. PubMed ID: 10997796
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Reliability and clinical impact of the normalization of the prothrombin times in oral anticoagulant control.
    Loeliger EA; van den Besselaar AM; Lewis SM
    Thromb Haemost; 1985 Feb; 53(1):148-54. PubMed ID: 3992514
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Evaluation of a portable prothrombin time monitor for home use by patients who require long-term oral anticoagulant therapy.
    Anderson DR; Harrison L; Hirsh J
    Arch Intern Med; 1993 Jun; 153(12):1441-7. PubMed ID: 8512435
    [TBL] [Abstract][Full Text] [Related]  

  • 47. International normalized ratio self-testing and self-management: improving patient outcomes.
    Pozzi M; Mitchell J; Henaine AM; Hanna N; Safi O; Henaine R
    Vasc Health Risk Manag; 2016; 12():387-392. PubMed ID: 27785043
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Coagulometer international sensitivity index (ISI) derivation, a rapid method using the prothrombin time/international normalized ratio (PT/INR) Line: a multicenter study.
    Poller L; Ibrahim S; Jespersen J; Pattison A
    J Thromb Haemost; 2012 Jul; 10(7):1379-84. PubMed ID: 22519939
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Mathematical derivative applied to international normalised ratio and analytical variations in oral anticoagulant therapy control.
    Introcaso G; Cuboni A; Ratto A; Foieni F
    Haemostasis; 2000; 30(6):281-9. PubMed ID: 11356996
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Field study of lyophilized calibrant plasmas for fresh plasma INR determination.
    van den Besselaar AM; Houbouyan-Réveillard LL
    Thromb Haemost; 2002 Feb; 87(2):277-81. PubMed ID: 11859852
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The international normalized ratio according to Owren in liver disease: interlaboratory assessment and determination of international sensitivity index.
    Magnusson M; Sten-Linder M; Bergquist A; Rajani R; Kechagias S; Fischler B; Németh A; Lindahl TL
    Thromb Res; 2013 Sep; 132(3):346-51. PubMed ID: 23993902
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Precision and accuracy of the international normalized ratio in oral anticoagulant control.
    van den Besselaar AM
    Haemostasis; 1996 Oct; 26 Suppl 4():248-65. PubMed ID: 8979131
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Multicenter evaluation of lyophilized and deep-frozen plasmas for assignment of the International Normalized Ratio.
    van den Besselaar AM; Houbouyan-Reveillard LL; Aillaud MF; Denson KW; Droullé C; Johnston M; Kitchen S; Lindahl TL; Marren M; Martinuzzo ME; Tripodi A; Vergnes C
    Thromb Haemost; 1999 Nov; 82(5):1451-5. PubMed ID: 10595637
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A modified international normalized ratio as an effective way of prothrombin time standardization in hepatology.
    Bellest L; Eschwège V; Poupon R; Chazouillères O; Robert A
    Hepatology; 2007 Aug; 46(2):528-34. PubMed ID: 17654598
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A primary care evaluation of three near patient coagulometers.
    Murray ET; Fitzmaurice DA; Allan TF; Hobbs FD
    J Clin Pathol; 1999 Nov; 52(11):842-5. PubMed ID: 10690176
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Self-management of oral anticoagulants with a whole blood prothrombin-time monitor in elderly patients with atrial fibrillation.
    Eldor A; Schwartz J
    Pathophysiol Haemost Thromb; 2002; 32(3):99-106. PubMed ID: 12372921
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Standardization of the INR: how good is your laboratory's INR and can it be improved?
    Favaloro EJ; Adcock DM
    Semin Thromb Hemost; 2008 Oct; 34(7):593-603. PubMed ID: 19085760
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Harmonizing the International Normalized Ratio (INR) : Standardization of Methods and Use of Novel Strategies to Reduce Interlaboratory Variation and Bias.
    Favaloro EJ; McVicker W; Lay M; Ahuja M; Zhang Y; Hamdam S; Hocker N
    Am J Clin Pathol; 2016 Feb; 145(2):191-202. PubMed ID: 26800763
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Correlation Between Home INR and Core Laboratory INR in Patients Supported with Continuous-Flow Left Ventricular Assist Devices.
    Dionizovik-Dimanovski M; Levin AP; Fried J; Mody KP; Simonich E; Garan AR; Yuzefpolskaya M; Takayama H; Naka Y; Colombo PC; Kalesan B; Uriel N; Jorde UP
    ASAIO J; 2015; 61(4):386-90. PubMed ID: 25905496
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring.
    Bereznicki LR; Jackson SL; Peterson GM; Jeffrey EC; Marsden KA; Jupe DM
    J Clin Pathol; 2007 Mar; 60(3):311-4. PubMed ID: 16751303
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.