These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Calibrated automated thrombin generation measurement in clotting plasma. Hemker HC; Giesen P; Al Dieri R; Regnault V; de Smedt E; Wagenvoord R; Lecompte T; Béguin S Pathophysiol Haemost Thromb; 2003; 33(1):4-15. PubMed ID: 12853707 [TBL] [Abstract][Full Text] [Related]
3. The calibrated automated thrombogram (CAT): a universal routine test for hyper- and hypocoagulability. Hemker HC; Giesen P; AlDieri R; Regnault V; de Smed E; Wagenvoord R; Lecompte T; Béguin S Pathophysiol Haemost Thromb; 2002; 32(5-6):249-53. PubMed ID: 13679651 [TBL] [Abstract][Full Text] [Related]
4. [Thrombinography: towards a globalization of coagulation tests]. Péters P; Gothot A Rev Med Liege; 2009 Apr; 64(4):199-203. PubMed ID: 19514539 [TBL] [Abstract][Full Text] [Related]
5. Thrombin generation in platelet-rich plasma as a tool for the detection of hypercoagulability in young stroke patients. Faber CG; Lodder J; Kessels F; Troost J Pathophysiol Haemost Thromb; 2003; 33(1):52-8. PubMed ID: 12853713 [TBL] [Abstract][Full Text] [Related]
6. Evolving techniques for monitoring clotting in plasma and whole blood samples. Carr ME; Martin EJ Clin Lab; 2004; 50(9-10):539-49. PubMed ID: 15481629 [TBL] [Abstract][Full Text] [Related]
7. The effect of DDAVP infusion on thrombin generation in platelet-rich plasma of von Willebrand type 1 and in mild haemophilia A patients. Keularts IM; Hamulyak K; Hemker HC; Béguin S Thromb Haemost; 2000 Oct; 84(4):638-42. PubMed ID: 11057863 [TBL] [Abstract][Full Text] [Related]
8. Thrombin generation assessed as endogenous thrombin potential in patients with hyper- or hypo-coagulability. Chantarangkul V; Clerici M; Bressi C; Giesen PL; Tripodi A Haematologica; 2003 May; 88(5):547-54. PubMed ID: 12745274 [TBL] [Abstract][Full Text] [Related]
9. Thrombin generation assay as a possible tool for assessment of reduced activity of clotting factors induced by antiphospholipid antibodies and in-vitro evaluation of treatment options. Livnat T; Zivelin A; Tamarin I; Guetta V; Salomon O Blood Coagul Fibrinolysis; 2009 Dec; 20(8):661-6. PubMed ID: 19730246 [TBL] [Abstract][Full Text] [Related]
10. Platelet-induced thrombin generation time: a new sensitive global assay for platelet function and coagulation. Method and first results. Basic-Micic M; Roman C; Herpel U; Kling E; Scholz B; Breddin HK Haemostasis; 1992; 22(6):309-21. PubMed ID: 1282490 [TBL] [Abstract][Full Text] [Related]
14. Platelet-dependent thrombin generation assay for monitoring the efficacy of recombinant Factor VIIa. Wegert W; Harder S; Bassus S; Kirchmaier CM Platelets; 2005 Feb; 16(1):45-50. PubMed ID: 15763896 [TBL] [Abstract][Full Text] [Related]
15. Calibrated automated thrombin generation in frozen-thawed platelet-rich plasma to detect hypercoagulability. Regnault V; Béguin S; Lecompte T Pathophysiol Haemost Thromb; 2003; 33(1):23-9. PubMed ID: 12853709 [TBL] [Abstract][Full Text] [Related]
16. Do we need a better test? Can thrombin generation be useful? Aledort LM Curr Hematol Rep; 2004 Mar; 3(2):75-6. PubMed ID: 14965481 [No Abstract] [Full Text] [Related]
17. Low agreement between fresh and frozen-thawed platelet-rich plasma in the calibrated automated thrombogram assay. Ljungkvist M; Lövdahl S; Zetterberg E; Berntorp E Haemophilia; 2017 May; 23(3):e214-e218. PubMed ID: 28145076 [TBL] [Abstract][Full Text] [Related]
18. Platelet-dependent coagulation assays for factor VIII efficacy measurement after substitution therapy in patients with haemophilia A. Bassus S; Wegert W; Krause M; Escuriola-Ettinghausen C; Siegemund A; Petros S; Scholz T; Scharrer I; Kreuz W; Engelmann L; Kirchmaier CM Platelets; 2006 Sep; 17(6):378-84. PubMed ID: 16973498 [TBL] [Abstract][Full Text] [Related]
19. Thrombin generation abnormalities in commonly encountered platelet function disorders. Sharma T; Brunet JG; Tasneem S; Smith SA; Morrissey JH; Hayward CPM Int J Lab Hematol; 2021 Dec; 43(6):1557-1565. PubMed ID: 34185390 [TBL] [Abstract][Full Text] [Related]
20. Assessment of the thrombin generation assay in haemophilia: comparative study between fresh and frozen platelet-rich plasma. Vila V; Aznar JA; Moret A; Marco A; Navarro S; Vila C; España F Haemophilia; 2013 Mar; 19(2):318-21. PubMed ID: 23174035 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]