These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
142 related articles for article (PubMed ID: 1526008)
1. A simplified procedure for eliminating the negative interference of bilirubin in the Jaffé reaction for creatinine. O'Leary N; Pembroke A; Duggan PF Clin Chem; 1992 Sep; 38(9):1749-51. PubMed ID: 1526008 [TBL] [Abstract][Full Text] [Related]
2. Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods. Srisawasdi P; Chaichanajarernkul U; Teerakanjana N; Vanavanan S; Kroll MH J Clin Lab Anal; 2010; 24(3):123-33. PubMed ID: 20486190 [TBL] [Abstract][Full Text] [Related]
3. Comparison of techniques for minimizing interference of bilirubin on serum creatinine determined by the kinetic Jaffé reaction. Lolekha PH; Sritong N J Clin Lab Anal; 1994; 8(6):391-9. PubMed ID: 7869178 [TBL] [Abstract][Full Text] [Related]
4. Oxidation markedly reduces bilirubin interference in the Jaffé creatinine assay. Rajs G; Mayer M Clin Chem; 1992 Dec; 38(12):2411-3. PubMed ID: 1333917 [TBL] [Abstract][Full Text] [Related]
6. Deproteinization of serum: another best approach to eliminate all forms of bilirubin interference on serum creatinine by the kinetic Jaffe reaction. Lolekha PH; Jaruthunyaluck S; Srisawasdi P J Clin Lab Anal; 2001; 15(3):116-21. PubMed ID: 11344525 [TBL] [Abstract][Full Text] [Related]
7. Serum ultrafiltration for the elimination of endogenous interfering substances in creatinine determination. da Fonseca-Wollheim F; Heinze KG; Lomsky K; Schreiner H J Clin Chem Clin Biochem; 1988 Aug; 26(8):523-5. PubMed ID: 3221182 [TBL] [Abstract][Full Text] [Related]
8. Glomerular filtration rate and creatinine production in adult icteric patients. Delanghe JR; Louagie HK; De Buyzere ML; Leroux-Roels GG Clin Chim Acta; 1994 Jan; 224(1):33-44. PubMed ID: 8174276 [TBL] [Abstract][Full Text] [Related]
9. When results matter: reliable creatinine concentrations in hyperbilirubinemia patients. Roelofsen-de Beer RJAC; van Zelst BD; Vroling AB; de Rijke YB; Ramakers C Clin Chem Lab Med; 2019 Apr; 57(5):659-667. PubMed ID: 30496132 [TBL] [Abstract][Full Text] [Related]
10. Investigations into negative interference by jaundiced plasma in kinetic Jaffé methods for plasma creatinine determination. Knapp ML; Hadid O Ann Clin Biochem; 1987 Jan; 24 ( Pt 1)():85-97. PubMed ID: 3827191 [TBL] [Abstract][Full Text] [Related]
11. Theoretical studies of biliverdin: energetics of the reduction pathways to bilirubin. Zahedi M; Kamalipour M; Safari N J Mol Model; 2002 Apr; 8(4):113-8. PubMed ID: 12111390 [TBL] [Abstract][Full Text] [Related]
12. A robust procedure for the automated measurement of total serum bilirubin using potassium ferricyanide. O'Leary N; Pembroke A; Duggan PF Ann Clin Biochem; 1993 Mar; 30 ( Pt 2)():175-9. PubMed ID: 8466149 [TBL] [Abstract][Full Text] [Related]
13. Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinine. Hermida FJ; Lorenzo MJ; Pérez A; Fernández M; Sagastagoia O; Magadán C Scand J Clin Lab Invest; 2014 Oct; 74(7):629-36. PubMed ID: 24988313 [TBL] [Abstract][Full Text] [Related]
14. [A negative interference effect of pathologic levels of bilirubin on the determination of serum creatinine]. Smrcková I; Charvát J; Malá D; Lácha J Cas Lek Cesk; 1999 Jun; 138(13):406-8. PubMed ID: 10566211 [TBL] [Abstract][Full Text] [Related]
15. A solution to the problem of bilirubin interference with the kinetic Jaffé method for serum creatinine. Osberg IM; Hammond KB Clin Chem; 1978 Jul; 24(7):1196-7. PubMed ID: 657504 [TBL] [Abstract][Full Text] [Related]
16. Determination of serum creatinine by Jaffe method and how to calibrate to eliminate matrix interference problems. Chromý V; Rozkosná K; Sedlák P Clin Chem Lab Med; 2008; 46(8):1127-33. PubMed ID: 18724810 [TBL] [Abstract][Full Text] [Related]
17. Prime time for enzymatic creatinine methods in pediatrics. Cobbaert CM; Baadenhuijsen H; Weykamp CW Clin Chem; 2009 Mar; 55(3):549-58. PubMed ID: 19168555 [TBL] [Abstract][Full Text] [Related]
18. Use of a synthetic soluble bilirubin derivative to assess interference in creatinine measurements. Franzini C; Morelli AM; Cattozzo G Clin Chem; 1991 Feb; 37(2):236-8. PubMed ID: 1993330 [TBL] [Abstract][Full Text] [Related]
19. Comparing Jaffe and Enzymatic Methods for Creatinine Measurement at Various Icterus Levels and Their Impacts on Liver Transplant Allocation. Soleimani N; Dehghani S; Anbardar MH; Mohammadzadeh S; Amirinezhad Fard E; Zare Sheibani A; Esmaeili MJ; Ebrahimi M Int J Anal Chem; 2023; 2023():9804533. PubMed ID: 37886708 [TBL] [Abstract][Full Text] [Related]
20. On how the conformation of biliverdins influences their reduction to bilirubins: a biological and molecular modeling study. Mora ME; Bari SE; Awruch J; Delfino JM Bioorg Med Chem; 2003 Oct; 11(21):4661-72. PubMed ID: 14527563 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]