These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 15262611)

  • 21. Should minimally invasive aortic valve replacement be restricted to primary interventions?
    Bakir I; Casselman FP; De Geest R; Wellens F; Degrieck I; Van Praet F; Vermeulen Y; Vanermen H
    Thorac Cardiovasc Surg; 2007 Aug; 55(5):304-9. PubMed ID: 17629860
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reoperative minimal access aortic valve surgery: minimal mediastinal dissection and minimal injury risk.
    Tabata M; Khalpey Z; Shekar PS; Cohn LH
    J Thorac Cardiovasc Surg; 2008 Dec; 136(6):1564-8. PubMed ID: 19114207
    [TBL] [Abstract][Full Text] [Related]  

  • 23. On-pump beating heart mitral valve surgery without cross-clamping the aorta.
    Katircioglu SF; Cicekcioglu F; Tutun U; Parlar AI; Babaroglu S; Mungan U; Aksoyek A
    J Card Surg; 2008; 23(4):307-11. PubMed ID: 18598319
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Long-term experience of girdling the ascending aorta with Dacron mesh as definitive treatment for aneurysmal dilation.
    Cohen O; Odim J; De la Zerda D; Ukatu C; Vyas R; Vyas N; Palatnik K; Laks H
    Ann Thorac Surg; 2007 Feb; 83(2):S780-4; discussion S785-90. PubMed ID: 17257926
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Minimally invasive cardiac surgery using port-access method].
    Kudo M; Yozu R
    Kyobu Geka; 2006 Jul; 59(8 Suppl):642-9. PubMed ID: 16910508
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Diagnosis and management of severe atherosclerosis of the ascending aorta and aortic arch during cardiac surgery: focus on aortic replacement.
    Zingone B; Rauber E; Gatti G; Pappalardo A; Benussi B; Forti G; Tognolli U; Gabrielli M
    Eur J Cardiothorac Surg; 2007 Jun; 31(6):990-7. PubMed ID: 17383888
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Minimal invasive cardiac surgery using port-access method in elderly patients].
    Kudo M; Yozu R
    Kyobu Geka; 2005 Jul; 58(8 Suppl):670-4. PubMed ID: 16097616
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Single crossclamp improves 6-month cognitive outcome in high-risk coronary bypass patients: the effect of reduced aortic manipulation.
    Hammon JW; Stump DA; Butterworth JF; Moody DM; Rorie K; Deal DD; Kincaid EH; Oaks TE; Kon ND
    J Thorac Cardiovasc Surg; 2006 Jan; 131(1):114-21. PubMed ID: 16399302
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Robotic assisted multivessel minimally invasive direct coronary artery bypass with port-access stabilization and cardiac positioning: paving the way for outpatient coronary surgery?
    Subramanian VA; Patel NU; Patel NC; Loulmet DF
    Ann Thorac Surg; 2005 May; 79(5):1590-6; discussion 1590-6. PubMed ID: 15854938
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Initial experience with the enclose proximal aortic anastomosis device during off-pump coronary artery bypass: an alternative to aortic side clamping.
    Boova RS; Trace C; Leshnower BG
    Heart Surg Forum; 2006; 9(2):E607-11. PubMed ID: 16543162
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Treatment of ascending aorta disease with Bentall-De Bono operation using a mini-invasive approach.
    Perrotta S; Lentini S; Rinaldi M; D'armini AM; Tancredi F; Raffa G; Gaeta R; Viganó M
    J Cardiovasc Med (Hagerstown); 2008 Oct; 9(10):1016-22. PubMed ID: 18799964
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Minimally invasive cardiac surgery using a flexible aortic clamp.
    Dandolu BR; Parmet JL; Yarnall C; Isidro A; Bridges CR
    Heart Surg Forum; 2007; 10(6):E428-30; discusson E430. PubMed ID: 17921127
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Thoracic aortic aneurysm repair. Direct hospital cost and Diagnosis Related Group reimbursement.
    Mishra V; Geiran O; Krohg-Sørensen K; Andresen S
    Scand Cardiovasc J; 2008 Feb; 42(1):77-84. PubMed ID: 18273734
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A strategy for safe sternal reentry in patients with pseudoaneurysms of the ascending aorta using the PORT-ACCESS EndoCPB system.
    Reyes KG; Pettersson GB; Mihaljevic T; Roselli EE
    Interact Cardiovasc Thorac Surg; 2009 Nov; 9(5):893-5. PubMed ID: 19720657
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Prospective evaluation of a 3-blade speculum cannula for minimally invasive lumbar microdiscectomy.
    Chin KR; Michener TA
    J Spinal Disord Tech; 2006 Jun; 19(4):257-61. PubMed ID: 16778659
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Minimally invasive aortic valve surgery: What is "port access"?
    Chitwood WR
    Am Heart J; 2001 Sep; 142(3):391-2. PubMed ID: 11526350
    [No Abstract]   [Full Text] [Related]  

  • 37. Minimally invasive port access versus conventional mitral valve surgery: prospective randomized study.
    Dogan S; Aybek T; Risteski PS; Detho F; Rapp A; Wimmer-Greinecker G; Moritz A
    Ann Thorac Surg; 2005 Feb; 79(2):492-8. PubMed ID: 15680822
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Anesthetic management of MICS with Port-Access system].
    Nakamura S; Asano H; Tuchiya M; Tabata M; Murakami Y; Aida H; Kyo S; Matsumoto I
    Masui; 2000 Nov; 49(11):1217-21. PubMed ID: 11215227
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Less invasive intracardiac surgery performed without aortic clamping.
    Loulmet DF; Patel NC; Jennings JM; Subramanian VA
    Ann Thorac Surg; 2008 May; 85(5):1551-5. PubMed ID: 18442536
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Twelve-month patency with the PAS-port proximal connector device: a single center prospective randomized trial.
    Kempfert J; Opfermann UT; Richter M; Bossert T; Mohr FW; Gummert JF
    Ann Thorac Surg; 2008 May; 85(5):1579-84. PubMed ID: 18442542
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.