These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 15263666)

  • 1. Optical design for laser Doppler angular encoder with sub-nrad sensitivity.
    Shu D; Alp EE; Barraza J; Kuzay TM; Mooney T
    J Synchrotron Radiat; 1998 May; 5(Pt 3):826-8. PubMed ID: 15263666
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A heterodyne interferometer for angle metrology.
    Hahn I; Weilert M; Wang X; Goullioud R
    Rev Sci Instrum; 2010 Apr; 81(4):045103. PubMed ID: 20441364
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Combining flat crystals, bent crystals and compound refractive lenses for high-energy X-ray optics.
    Shastri SD
    J Synchrotron Radiat; 2004 Mar; 11(Pt 2):150-6. PubMed ID: 14960779
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a three-degree-of-freedom laser linear encoder for error measurement of a high precision stage.
    Huang HL; Liu CH; Jywe WY; Wang MS; Fang TH
    Rev Sci Instrum; 2007 Jun; 78(6):066103. PubMed ID: 17614647
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Portable laser-heating stand for synchrotron applications.
    Boehler R; Musshoff HG; Ditz R; Aquilanti G; Trapananti A
    Rev Sci Instrum; 2009 Apr; 80(4):045103. PubMed ID: 19405687
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Precision wavelength measurement of the 14.4 keV Mössbauer photon.
    Xiaowei Z; Yoda Y; Imai Y
    J Synchrotron Radiat; 2000 May; 7(Pt 3):189-95. PubMed ID: 16609194
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nanoradian angular stabilization of x-ray optical components.
    Stoupin S; Lenkszus F; Laird R; Goetze K; Kim KJ; Shvyd'ko Y
    Rev Sci Instrum; 2010 May; 81(5):055108. PubMed ID: 20515173
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical investigation of the combination of a scanning laser ophthalmoscope and laser Doppler flowmeter.
    Michelson G; Langhans MJ; Groh MJ
    Ger J Ophthalmol; 1995 Nov; 4(6):342-9. PubMed ID: 8751099
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A soft x-ray beamline capable of canceling the performance impairment due to power absorbed on its optical elements.
    Reininger R; Kriesel K; Hulbert SL; Sánchez-Hanke C; Arena DA
    Rev Sci Instrum; 2008 Mar; 79(3):033108. PubMed ID: 18376998
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A dual-heterodyne laser interferometer for simultaneous measurement of linear and angular displacements.
    Yan H; Duan HZ; Li LT; Liang YR; Luo J; Yeh HC
    Rev Sci Instrum; 2015 Dec; 86(12):123102. PubMed ID: 26724001
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interferometer-controlled scanning transmission X-ray microscopes at the Advanced Light Source.
    Kilcoyne AL; Tyliszczak T; Steele WF; Fakra S; Hitchcock P; Franck K; Anderson E; Harteneck B; Rightor EG; Mitchell GE; Hitchcock AP; Yang L; Warwick T; Ade H
    J Synchrotron Radiat; 2003 Mar; 10(Pt 2):125-36. PubMed ID: 12606790
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optical design of the U7 undulator beamline at the Pohang Light Source.
    Shin HJ; Chung Y; Kim B
    J Synchrotron Radiat; 1998 May; 5(Pt 3):648-50. PubMed ID: 15263607
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [2-dimensional mapping and retinal and papillary microcirculation using scanning laser Doppler flowmetry].
    Michelson G; Groh M; Langhans M; Schmauss B
    Klin Monbl Augenheilkd; 1995 Sep; 207(3):180-90. PubMed ID: 7474787
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Laser beam angular stabilization system based on a compact interferometer and a precise double-wedge deflector.
    Tyszka K; Dobosz M
    Rev Sci Instrum; 2018 Aug; 89(8):085121. PubMed ID: 30184702
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optical design of the NSRL undulator beamline.
    Zhang YW; Sheng LS; Zhang GB; Gao H
    J Synchrotron Radiat; 1998 May; 5(Pt 3):559-61. PubMed ID: 15263578
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-energy X-ray optics with silicon saw-tooth refractive lenses.
    Shastri SD; Almer J; Ribbing C; Cederström B
    J Synchrotron Radiat; 2007 Mar; 14(Pt 2):204-11. PubMed ID: 17317922
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High repetition rate laser produced soft x-ray source for ultrafast x-ray absorption near edge structure measurements.
    Fourmaux S; Lecherbourg L; Harmand M; Servol M; Kieffer JC
    Rev Sci Instrum; 2007 Nov; 78(11):113104. PubMed ID: 18052462
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Holographic common-path interferometer for angular displacement measurements with spatial phase stepping and extended measurement range.
    Kitchen SR; Dam-Hansen C
    Appl Opt; 2003 Jan; 42(1):51-9. PubMed ID: 12518823
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Common-path laser planar encoder.
    Wu CC; Chen YZ; Liao CH
    Opt Express; 2013 Aug; 21(16):18872-83. PubMed ID: 23938800
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An alternative scheme of angular-dispersion analyzers for high-resolution medium-energy inelastic X-ray scattering.
    Huang XR
    J Synchrotron Radiat; 2011 Nov; 18(Pt 6):899-906. PubMed ID: 21997915
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.