These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. A plane-grating monochromator for circularly polarized undulator radiation at BESSY II. Senf F; Sawhney KJ; Follath R; Scheer M; Schäfers F; Bahrdt J; Gaupp A; Gudat W J Synchrotron Radiat; 1998 May; 5(Pt 3):747-9. PubMed ID: 15263640 [TBL] [Abstract][Full Text] [Related]
23. Soft X-ray coherent scattering: instrument and methods at ESRF ID08. Beutier G; Marty A; Livet F; van der Laan G; Stanescu S; Bencok P Rev Sci Instrum; 2007 Sep; 78(9):093901. PubMed ID: 17902956 [TBL] [Abstract][Full Text] [Related]
24. An inelastic X-ray scattering spectrometer at LNLS. Tirao G; Stutz G; Cusatis C J Synchrotron Radiat; 2004 Jul; 11(Pt 4):335-42. PubMed ID: 15211040 [TBL] [Abstract][Full Text] [Related]
25. Recent trends in total reflection X-ray fluorescence spectrometry for biological applications. Szoboszlai N; Polgári Z; Mihucz VG; Záray G Anal Chim Acta; 2009 Feb; 633(1):1-18. PubMed ID: 19110110 [TBL] [Abstract][Full Text] [Related]
26. A setup for synchrotron-radiation-induced total reflection X-ray fluorescence and X-ray absorption near-edge structure recently commissioned at BESSY II BAMline. Fittschen U; Guilherme A; Böttger S; Rosenberg D; Menzel M; Jansen W; Busker M; Gotlib ZP; Radtke M; Riesemeier H; Wobrauschek P; Streli C J Synchrotron Radiat; 2016 May; 23(Pt 3):820-4. PubMed ID: 27140163 [TBL] [Abstract][Full Text] [Related]
27. High-throughput asymmetric double-crystal monochromator of the SAXS beamline at ELETTRA. Bernstorff S; Amenitsch H; Laggner P J Synchrotron Radiat; 1998 Jul; 5(Pt 4):1215-21. PubMed ID: 16687824 [TBL] [Abstract][Full Text] [Related]
28. The MX2 macromolecular crystallography beamline: a wiggler X-ray source at the LNLS. Guimarães BG; Sanfelici L; Neuenschwander RT; Rodrigues F; Grizolli WC; Raulik MA; Piton JR; Meyer BC; Nascimento AS; Polikarpov I J Synchrotron Radiat; 2009 Jan; 16(Pt 1):69-75. PubMed ID: 19096177 [TBL] [Abstract][Full Text] [Related]
29. Total reflection X-ray spectrometry (TXRF) for trace elements assessment in edible clams. Marguí E; de Fátima Marques A; de Lurdes Prisal M; Hidalgo M; Queralt I; Carvalho ML Appl Spectrosc; 2014; 68(11):1241-6. PubMed ID: 25286343 [TBL] [Abstract][Full Text] [Related]
30. Lower limits of detection of synchrotron radiation high-energy X-ray fluorescence spectrometry and its possibility for the forensic application for discrimination of glass fragments. Nakanishi T; Nishiwaki Y; Miyamoto N; Shimoda O; Watanabe S; Muratsu S; Takatsu M; Terada Y; Suzuki Y; Kasamatsu M; Suzuki S Forensic Sci Int; 2008 Mar; 175(2-3):227-34. PubMed ID: 17764863 [TBL] [Abstract][Full Text] [Related]
32. A high-throughput structural biology/proteomics beamline at the SRS on a new multipole wiggler. Cianci M; Antonyuk S; Bliss N; Bailey MW; Buffey SG; Cheung KC; Clarke JA; Derbyshire GE; Ellis MJ; Enderby MJ; Grant AF; Holbourn MP; Laundy D; Nave C; Ryder R; Stephenson P; Helliwell JR; Hasnain SS J Synchrotron Radiat; 2005 Jul; 12(Pt 4):455-66. PubMed ID: 15968122 [TBL] [Abstract][Full Text] [Related]
33. Note: Construction of x-ray scattering and x-ray absorption fine structure beamline at the Pohang Light Source. Lee IJ; Yu CJ; Yun YD; Lee CS; Seo ID; Kim HY; Lee WW; Chae KH Rev Sci Instrum; 2010 Feb; 81(2):026103. PubMed ID: 20192520 [TBL] [Abstract][Full Text] [Related]
34. Development of a new state-of-the-art beamline optimized for monochromatic single-crystal and powder X-ray diffraction under extreme conditions at the ESRF. Mezouar M; Crichton WA; Bauchau S; Thurel F; Witsch H; Torrecillas F; Blattmann G; Marion P; Dabin Y; Chavanne J; Hignette O; Morawe C; Borel C J Synchrotron Radiat; 2005 Sep; 12(Pt 5):659-64. PubMed ID: 16120991 [TBL] [Abstract][Full Text] [Related]
35. Development of a two-dimensionally tunable focusing monochromator for protein crystallography at high-energy undulator beamlines. Kawano Y; Kamiya N J Synchrotron Radiat; 1996 Mar; 3(Pt 2):53-61. PubMed ID: 16702659 [TBL] [Abstract][Full Text] [Related]
36. Conserving the coherence and uniformity of third-generation synchrotron radiation beams: the case of ID19, a 'long' beamline at the ESRF. Espeso JI; Cloetens P; Baruchel J; Härtwig J; Mairs T; Biasci JC; Marot G; Salomé-Pateyron M; Schlenker M J Synchrotron Radiat; 1998 Sep; 5(Pt 5):1243-9. PubMed ID: 16687829 [TBL] [Abstract][Full Text] [Related]
37. ID22: a multitechnique hard X-ray microprobe beamline at the European Synchrotron Radiation Facility. Somogyi A; Tucoulou R; Martinez-Criado G; Homs A; Cauzid J; Bleuet P; Bohic S; Simionovici A J Synchrotron Radiat; 2005 Mar; 12(Pt 2):208-15. PubMed ID: 15728973 [TBL] [Abstract][Full Text] [Related]
38. Accurate calibration of TXRF using microdroplet samples. Fabry L; Pahlke S; Kotz L Anal Bioanal Chem; 1996 Jan; 354(3):266-70. PubMed ID: 15048446 [TBL] [Abstract][Full Text] [Related]
39. In situ removal of carbon contamination from optics in a vacuum ultraviolet and soft X-ray undulator beamline using oxygen activated by zeroth-order synchrotron radiation. Toyoshima A; Kikuchi T; Tanaka H; Adachi JI; Mase K; Amemiya K J Synchrotron Radiat; 2012 Sep; 19(Pt 5):722-7. PubMed ID: 22898952 [TBL] [Abstract][Full Text] [Related]
40. Quick-scanning x-ray absorption spectroscopy system with a servo-motor-driven channel-cut monochromator with a temporal resolution of 10 ms. Nonaka T; Dohmae K; Araki T; Hayashi Y; Hirose Y; Uruga T; Yamazaki H; Mochizuki T; Tanida H; Goto S Rev Sci Instrum; 2012 Aug; 83(8):083112. PubMed ID: 22938279 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]