These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 15263830)

  • 1. Implantation of novel small-diameter polyurethane vascular prostheses interposed in canine femoral and carotid arteries.
    Karapinar K; Ulus AT; Tütün U; Aksöyek A; Apaydin N; Pamuk K; Can Z; Saritaş Z; Küçükay F; Arda K; Katircioğlu SF
    Eur Surg Res; 2004; 36(4):241-8. PubMed ID: 15263830
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noninvasive color Doppler inspection of small-diameter vascular grafts implanted in canine carotid and femoral arteries.
    Sung HW; Witzel TH; Hata C; Tu R; Quijano RC
    Artif Organs; 1992 Oct; 16(5):485-9. PubMed ID: 10078297
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Patency rate of small caliber fibrous polyurethane vascular prostheses implanted in the dog carotid and femoral artery improved by use of acetylsalicylic acid and dipyridamol.
    Hess F; Steeghs S; Braun B; van Det R; Grande P; Jerusalem C; Skotnicki S
    Thorac Cardiovasc Surg; 1988 Aug; 36(4):221-6. PubMed ID: 3187983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel bioengineered small-caliber vascular graft incorporating heparin and sirolimus: excellent 6-month patency.
    Ishii Y; Sakamoto S; Kronengold RT; Virmani R; Rivera EA; Goldman SM; Prechtel EJ; Hill JG; Damiano RJ
    J Thorac Cardiovasc Surg; 2008 Jun; 135(6):1237-45; discussion 1245-6. PubMed ID: 18544361
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Compliance effects on small diameter polyurethane graft patency.
    Uchida N; Kambic H; Emoto H; Chen JF; Hsu S; Murabayshi S; Harasaki H; Nosé Y
    J Biomed Mater Res; 1993 Oct; 27(10):1269-79. PubMed ID: 8245041
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Compliance effect on patency of small diameter vascular grafts.
    Uchida N; Emoto H; Kambic H; Harasaki H; Chen JF; Hsu SH; Murabayashi S; Nosé Y
    ASAIO Trans; 1989; 35(3):556-8. PubMed ID: 2597533
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental studies on application of small-caliber vascular prosthesis produced by polyurethane.
    Miyamoto K; Sugimoto T; Okada M; Maeda S
    Ann Thorac Cardiovasc Surg; 1999 Jun; 5(3):174-81. PubMed ID: 10413764
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hydrophilic microporous polyurethane versus expanded PTFE grafts as substitutes in the carotid arteries of dogs. A limited study.
    Martz H; Paynter R; Ben Slimane S; Beaudoin G; Guidoin R; Borzone J; Ben Simhon H; Satin R; Sheiner N
    J Biomed Mater Res; 1988 Jan; 22(1):63-9. PubMed ID: 3343258
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Novel synthetic selectively degradable vascular prostheses: a preliminary implantation study.
    Izhar U; Schwalb H; Borman JB; Hellener GR; Hotoveli-Salomon A; Marom G; Stern T; Cohn D
    J Surg Res; 2001 Feb; 95(2):152-60. PubMed ID: 11162039
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prevention of neointimal hyperplasia associated with modified stretch expanded polytetrafluoroethylene hemodialysis grafts (Gore) in an experimental preclinical study in swine.
    Gessaroli M; Bombardi C; Giunti M; Bacci ML
    J Vasc Surg; 2012 Jan; 55(1):192-202. PubMed ID: 21944911
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A two year study of the performance of a small diameter polyurethane (Biomer) arterial prosthesis.
    de Cossart L; How TV; Annis D
    J Cardiovasc Surg (Torino); 1989; 30(3):388-94. PubMed ID: 2745525
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Test of carotid artery replacement by polyurethane artificial vascular graft with recombinant fibrinolytic enzyme factor II-modified lumina in dogs].
    Pan S; Yin S; Yao J; Zheng H; Yi W; Dai G
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jul; 22(7):832-7. PubMed ID: 18681285
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Small intestinal submucosa as a small-diameter arterial graft in the dog.
    Lantz GC; Badylak SF; Coffey AC; Geddes LA; Blevins WE
    J Invest Surg; 1990; 3(3):217-27. PubMed ID: 2078544
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A compliant Corethane/Dacron composite vascular prosthesis. Comparison with 4-mm ePTFE grafts in a canine model.
    Wilson GJ; MacGregor DC; Klement P; Weber BA; Binnington AG; Pinchuk L
    ASAIO J; 1993; 39(3):M526-31. PubMed ID: 8268591
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The direct effect of graft compliance mismatch per se on development of host arterial intimal hyperplasia at the anastomotic interface.
    Wu MH; Shi Q; Sauvage LR; Kaplan S; Hayashida N; Patel MD; Wechezak AR; Walker MW
    Ann Vasc Surg; 1993 Mar; 7(2):156-68. PubMed ID: 8518133
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Development of a method to prevent degenerative changes of the vein graft for arterial reconstruction].
    Sato S; Niu S; Kanda K; Oka T; Wildevuur CR
    Nihon Geka Gakkai Zasshi; 1992 Apr; 93(4):419-28. PubMed ID: 1603048
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An integrated approach to the design and engineering of hybrid arterial prostheses.
    Miwa H; Matsuda T
    J Vasc Surg; 1994 Apr; 19(4):658-67. PubMed ID: 8164281
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Incidentally detected stenoses proximal to grafts originating below the common femoral artery: do they affect graft patency or warrant repair in asymptomatic patients?
    Treiman GS; Ashrafi A; Lawrence PF
    J Vasc Surg; 2000 Dec; 32(6):1180-9. PubMed ID: 11107091
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of implantation site on outcome of tissue-engineered vascular grafts.
    Sologashvili T; Saat SA; Tille JC; De Valence S; Mugnai D; Giliberto JP; Dillon J; Yakub A; Dimon Z; Gurny R; Walpoth BH; Moeller M
    Eur J Pharm Biopharm; 2019 Jun; 139():272-278. PubMed ID: 31004790
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The composite Corethane/Dacron vascular prosthesis. Canine in vivo evaluation of 4 mm diameter grafts with 1 year follow-up.
    Wilson GJ; MacGregor DC; Klement P; Dereume JP; Weber BA; Binnington AG; Pinchuk L
    ASAIO Trans; 1991; 37(3):M475-6. PubMed ID: 1836338
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.