These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

280 related articles for article (PubMed ID: 15269802)

  • 41. Microfluidic assembly blocks.
    Rhee M; Burns MA
    Lab Chip; 2008 Aug; 8(8):1365-73. PubMed ID: 18651080
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Simulation-based analysis of fluid flow and electrokinetic phenomena in microfluidic devices.
    Krishnamoorthy S; Bedekar AS; Feng J; Sundaram S
    Clin Lab Med; 2007 Mar; 27(1):41-59. PubMed ID: 17416301
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Three-dimensional surface microfluidics enabled by spatiotemporal control of elastic fluidic interface.
    Hong L; Pan T
    Lab Chip; 2010 Dec; 10(23):3271-6. PubMed ID: 20931123
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Control and detection of chemical reactions in microfluidic systems.
    DeMello AJ
    Nature; 2006 Jul; 442(7101):394-402. PubMed ID: 16871207
    [TBL] [Abstract][Full Text] [Related]  

  • 45. A capillary-based microfluidic instrument suitable for immunoaffinity chromatography.
    Peoples MC; Phillips TM; Karnes HT
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Apr; 848(2):200-7. PubMed ID: 17097929
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A study of mixing in thermocapillary flows on micropatterned surfaces.
    Darhuber AA; Chen JZ; Davis JM; Troian SM
    Philos Trans A Math Phys Eng Sci; 2004 May; 362(1818):1037-58. PubMed ID: 15306483
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Designing for chaos: applications of chaotic advection at the microscale.
    Stremler MA; Haselton FR; Aref H
    Philos Trans A Math Phys Eng Sci; 2004 May; 362(1818):1019-36. PubMed ID: 15306482
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Influence of hydrodynamic conditions on quantitative cellular assays in microfluidic systems.
    Yin H; Zhang X; Pattrick N; Klauke N; Cordingley HC; Haswell SJ; Cooper JM
    Anal Chem; 2007 Sep; 79(18):7139-44. PubMed ID: 17658886
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Chemical and physical processes for integrated temperature control in microfluidic devices.
    Guijt RM; Dodge A; van Dedem GW; de Rooij NF; Verpoorte E
    Lab Chip; 2003 Feb; 3(1):1-4. PubMed ID: 15100796
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Applying microfluidics to electrophysiology.
    Eddington DT
    J Vis Exp; 2007; (8):301. PubMed ID: 18989410
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Design and evaluation of a Dean vortex-based micromixer.
    Howell PB; Mott DR; Golden JP; Ligler FS
    Lab Chip; 2004 Dec; 4(6):663-9. PubMed ID: 15570382
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Potentiometric titrations in a poly(dimethylsiloxane)-based microfluidic device.
    Ferrigno R; Lee JN; Jiang X; Whitesides GM
    Anal Chem; 2004 Apr; 76(8):2273-80. PubMed ID: 15080738
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Microfluidic stickers for cell- and tissue-based assays in microchannels.
    Morel M; Bartolo D; Galas JC; Dahan M; Studer V
    Lab Chip; 2009 Apr; 9(7):1011-3. PubMed ID: 19294316
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Why the move to microfluidics for protein analysis?
    Lion N; Reymond F; Girault HH; Rossier JS
    Curr Opin Biotechnol; 2004 Feb; 15(1):31-7. PubMed ID: 15102463
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Chemical imaging of microfluidic flows using ATR-FTIR spectroscopy.
    Chan KL; Gulati S; Edel JB; de Mello AJ; Kazarian SG
    Lab Chip; 2009 Oct; 9(20):2909-13. PubMed ID: 19789743
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends.
    Zhang C; Xing D; Li Y
    Biotechnol Adv; 2007; 25(5):483-514. PubMed ID: 17601695
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Electroosmotic guiding of sample flows in a laminar flow chamber.
    Besselink GA; Vulto P; Lammertink RG; Schlautmann S; van den Berg A; Olthuis W; Engbers GH; Schasfoort RB
    Electrophoresis; 2004 Nov; 25(21-22):3705-11. PubMed ID: 15565693
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Generation of dynamic chemical signals with microfluidic C-DACs.
    Chen L; Azizi F; Mastrangelo CH
    Lab Chip; 2007 Jul; 7(7):850-5. PubMed ID: 17594003
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Design of a recursively-structured valveless device for microfluidic manipulation.
    Chung YC; Jen CP; Lin YC; Wu CY; Wu TC
    Lab Chip; 2003 Aug; 3(3):168-72. PubMed ID: 15100769
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Suppression of non-specific adsorption using sheath flow.
    Munson MS; Hasenbank MS; Fu E; Yager P
    Lab Chip; 2004 Oct; 4(5):438-45. PubMed ID: 15472727
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.