100 related articles for article (PubMed ID: 1527144)
1. A prospective comparison of ankle/brachial indices and color duplex imaging in surveillance of the in situ saphenous vein bypass.
Laborde AL; Synn AY; Worsey MJ; Bower TR; Hoballah JJ; Sharp WJ; Kresowik TF; Corson JD
J Cardiovasc Surg (Torino); 1992; 33(4):420-5. PubMed ID: 1527144
[TBL] [Abstract][Full Text] [Related]
2. Impact of a color-flow duplex surveillance program on infrainguinal vein graft patency: a five-year experience.
Idu MM; Blankenstein JD; de Gier P; Truyen E; Buth J
J Vasc Surg; 1993 Jan; 17(1):42-52; discussion 52-3. PubMed ID: 8421341
[TBL] [Abstract][Full Text] [Related]
3. Early post-operative ankle pressure indices help predict late patency rates after femoro-distal vein bypass grafting.
Prime HT; Myers KA; Matthews PG; Zeng G
J Cardiovasc Surg (Torino); 1992; 33(4):426-31. PubMed ID: 1527145
[TBL] [Abstract][Full Text] [Related]
4. The impact of color duplex surveillance on the outcome of lower limb bypass with segments of arm veins.
Chalmers RT; Hoballah JJ; Kresowik TF; Sharp WJ; Synn AY; Miller E; Corson JD
J Vasc Surg; 1994 Feb; 19(2):279-86; discussion 286-8. PubMed ID: 8114189
[TBL] [Abstract][Full Text] [Related]
5. Surveillance of in situ infrainguinal bypass grafts: conventional vs. color flow duplex ultrasonography.
Killewich LA; Fisher C; Bartlett ST
J Cardiovasc Surg (Torino); 1990; 31(5):662-7. PubMed ID: 2229168
[TBL] [Abstract][Full Text] [Related]
6. Prospective validation of threshold criteria for intervention in infrainguinal vein grafts undergoing duplex surveillance.
Westerband A; Mills JL; Kistler S; Berman SS; Hunter GC; Marek JM
Ann Vasc Surg; 1997 Jan; 11(1):44-8. PubMed ID: 9061138
[TBL] [Abstract][Full Text] [Related]
7. Comparison of infrainguinal graft surveillance techniques.
Green RM; McNamara J; Ouriel K; DeWeese JA
J Vasc Surg; 1990 Feb; 11(2):207-14; discussion 214-5. PubMed ID: 2405194
[TBL] [Abstract][Full Text] [Related]
8. Color-flow duplex criteria for grading stenosis in infrainguinal vein grafts.
Buth J; Disselhoff B; Sommeling C; Stam L
J Vasc Surg; 1991 Dec; 14(6):716-26; discussion 726-8. PubMed ID: 1960803
[TBL] [Abstract][Full Text] [Related]
9. Does correction of stenoses identified with color duplex scanning improve infrainguinal graft patency?
Mattos MA; van Bemmelen PS; Hodgson KJ; Ramsey DE; Barkmeier LD; Sumner DS
J Vasc Surg; 1993 Jan; 17(1):54-64; discussion 64-6. PubMed ID: 8421342
[TBL] [Abstract][Full Text] [Related]
10. Early detection of saphenous vein arterial bypass graft stenosis by color-assisted duplex sonography: a prospective study.
Polak JF; Donaldson MC; Dobkin GR; Mannick JA; O'Leary DH
AJR Am J Roentgenol; 1990 Apr; 154(4):857-61. PubMed ID: 2107689
[TBL] [Abstract][Full Text] [Related]
11. Femoropopliteal-crural graft patency is improved by an intensive surveillance program: a prospective randomized study.
Lundell A; Lindblad B; Bergqvist D; Hansen F
J Vasc Surg; 1995 Jan; 21(1):26-33; discussion 33-4. PubMed ID: 7823359
[TBL] [Abstract][Full Text] [Related]
12. The importance of routine surveillance of distal bypass grafts with duplex scanning: a study of 379 reversed vein grafts.
Mills JL; Harris EJ; Taylor LM; Beckett WC; Porter JM
J Vasc Surg; 1990 Oct; 12(4):379-86; discussion 387-9. PubMed ID: 2214034
[TBL] [Abstract][Full Text] [Related]
13. Simple hyperaemia test as a screening method in the postoperative surveillance of infrainguinal in situ vein bypasses.
Nielsen TG; Sillesen H; Schroeder TV
Eur J Vasc Endovasc Surg; 1995 Oct; 10(3):298-303. PubMed ID: 7552528
[TBL] [Abstract][Full Text] [Related]
14. The impact of angiodynography on infrainguinal bypass graft surveillance.
Jain KM; Simoni EJ; Munn JS
J Cardiovasc Surg (Torino); 1992; 33(3):337-43. PubMed ID: 1601919
[TBL] [Abstract][Full Text] [Related]
15. The Role of Routine Ultrasound Surveillance after In Situ Infrainguinal Peripheral Vein Bypass for Critical Limb-Threatening Ischemia.
Fisker L; Eiberg J; Sillesen H; Lawaetz M
Ann Vasc Surg; 2020 Jul; 66():529-536. PubMed ID: 32035262
[TBL] [Abstract][Full Text] [Related]
16. Monitoring functional patency of in situ saphenous vein bypasses: the impact of a surveillance protocol and elective revision.
Bandyk DF; Schmitt DD; Seabrook GR; Adams MB; Towne JB
J Vasc Surg; 1989 Feb; 9(2):286-96. PubMed ID: 2521907
[TBL] [Abstract][Full Text] [Related]
17. Early detection of stenosis of femoro-distal grafts. A surveillance study using colour-duplex scanning.
Disselhoff B; Buth J; Jakimowicz J
Eur J Vasc Surg; 1989 Feb; 3(1):43-8. PubMed ID: 2653868
[TBL] [Abstract][Full Text] [Related]
18. Duplex imaging of in situ saphenous vein bypass grafts and late failure reduction.
Bartlett ST; Killewich LA; Fisher C; Ward RE
Am J Surg; 1988 Dec; 156(6):484-7. PubMed ID: 3059838
[TBL] [Abstract][Full Text] [Related]
19. Therapeutic options for acute thrombosed in situ saphenous vein arterial bypass grafts.
Bandyk DF; Towne JB; Schmitt DD; Seabrook GR; Bergamini TM
J Vasc Surg; 1990 May; 11(5):680-7. PubMed ID: 2335834
[TBL] [Abstract][Full Text] [Related]
20. [Duplex sonographic monitoring of infra-inguinal arterial reconstructions: can a threatened bypass occlusion be detected by this method?].
Wölfle KD; Neudert S; Mayer B; Storm G; Bruijnen H; Loeprecht H
Zentralbl Chir; 1992; 117(10):540-6. PubMed ID: 1441777
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]