213 related articles for article (PubMed ID: 15272541)
1. Identification of unsuspected PNH-type cells in flow cytometric immunophenotypic analysis of peripheral blood and bone marrow.
Thomason RW; Papiez J; Lee RV; Szczarkowski W
Am J Clin Pathol; 2004 Jul; 122(1):128-34. PubMed ID: 15272541
[TBL] [Abstract][Full Text] [Related]
2. Differential usefulness of various markers in the flow cytometric detection of paroxysmal nocturnal hemoglobinuria in blood and bone marrow.
Olteanu H; Karandikar NJ; McKenna RW; Xu Y
Am J Clin Pathol; 2006 Nov; 126(5):781-8. PubMed ID: 17050075
[TBL] [Abstract][Full Text] [Related]
3. Diagnosis of paroxysmal nocturnal hemoglobinuria in peripheral blood and bone marrow with six-color flow cytometry.
Yang HS; Yang M; Li X; Tugulea S; Dong H
Biomark Med; 2013 Feb; 7(1):99-111. PubMed ID: 23387491
[TBL] [Abstract][Full Text] [Related]
4. A cohort study of the nature of paroxysmal nocturnal hemoglobinuria clones and PIG-A mutations in patients with aplastic anemia.
Wanachiwanawin W; Siripanyaphinyo U; Piyawattanasakul N; Kinoshita T
Eur J Haematol; 2006 Jun; 76(6):502-9. PubMed ID: 16529603
[TBL] [Abstract][Full Text] [Related]
5. Detailed immunophenotypic characterization of different major and minor subsets of peripheral blood cells in patients with paroxysmal nocturnal hemoglobinuria.
Hernández-Campo PM; Almeida J; Acevedo MJ; Sánchez ML; Alberca I; Vidriales B; Martínez E; Romero JR; Orfao A
Transfusion; 2008 Jul; 48(7):1403-14. PubMed ID: 18422849
[TBL] [Abstract][Full Text] [Related]
6. Quantitation of CD55 and CD59 expression on reticulocytes and mature erythrocytes in paroxysmal nocturnal hemoglobinuria, aplastic anemia, and healthy control subjects.
Kim Y; Lim J; Kim M; Kim Y; Lee JW; Han K
Ann Clin Lab Sci; 2010; 40(3):226-32. PubMed ID: 20689133
[TBL] [Abstract][Full Text] [Related]
7. Comparative analysis of different flow cytometry-based immunophenotypic methods for the analysis of CD59 and CD55 expression on major peripheral blood cell subsets.
Hernández-Campo PM; Martín-Ayuso M; Almeida J; López A; Orfao A
Cytometry; 2002 Jun; 50(3):191-201. PubMed ID: 12116342
[TBL] [Abstract][Full Text] [Related]
8. Paroxysmal nocturnal hemoglobinuria testing by flow cytometry. Evaluation of the REDQUANT and CELLQUANT kits.
Hsi ED
Am J Clin Pathol; 2000 Nov; 114(5):798-806. PubMed ID: 11068556
[TBL] [Abstract][Full Text] [Related]
9. Flow cytometric analysis of glycosylphosphatidyl-inositol-anchored proteins to assess paroxysmal nocturnal hemoglobinuria clone size.
Piedras J; López-Karpovitch X
Cytometry; 2000 Aug; 42(4):234-8. PubMed ID: 10934342
[TBL] [Abstract][Full Text] [Related]
10. Flow cytometric analysis of erythrocytes in paroxysmal nocturnal hemoglobinuria reveals superiority of CD59 as a diagnostic marker compared to CD55.
Tembhare P; Ramani M; Syed K; Gupta AD
Indian J Pathol Microbiol; 2010; 53(4):699-703. PubMed ID: 21045396
[TBL] [Abstract][Full Text] [Related]
11. A prospective comparison of four techniques for diagnosis of paroxysmal nocturnal hemoglobinuria.
Gupta R; Pandey P; Choudhry R; Kashyap R; Mehrotra M; Naseem S; Nityanand S
Int J Lab Hematol; 2007 Apr; 29(2):119-26. PubMed ID: 17474884
[TBL] [Abstract][Full Text] [Related]
12. Value of CD16/CD66b/CD45 in comparison to CD55/CD59/CD45 in diagnosis of paroxysmal nocturnal haemoglobinuria: An Indian experience.
Kotru M; Sharma R; Pramanik SK; Purohit A; Singh G; Singh AK; Muterja D; Mishra P; Seth T; Tyagi S; Mahapatra M; Pati HP; Saxena R
Indian J Med Res; 2017 Sep; 146(3):362-368. PubMed ID: 29355143
[TBL] [Abstract][Full Text] [Related]
13. Diagnosing PNH with FLAER and multiparameter flow cytometry.
Sutherland DR; Kuek N; Davidson J; Barth D; Chang H; Yeo E; Bamford S; Chin-Yee I; Keeney M
Cytometry B Clin Cytom; 2007 May; 72(3):167-77. PubMed ID: 17285629
[TBL] [Abstract][Full Text] [Related]
14. Expression of phosphatidylinositol anchored membrane proteins in paroxysmal nocturnal haemoglobinuria after bone marrow transplantation.
Perez-Oteyza J; Roldan E; Brieva JA; Cancelas JA; Garcia-Larana J; Odriozola J; Hernandez Jodra M; Navarro JL
Bone Marrow Transplant; 1992 Sep; 10(3):297-9. PubMed ID: 1384901
[TBL] [Abstract][Full Text] [Related]
15. A systematic analysis of bone marrow cells by flow cytometry defines a specific phenotypic profile beyond GPI deficiency in paroxysmal nocturnal hemoglobinuria.
Mannelli F; Bencini S; Peruzzi B; Cutini I; Sanna A; Benelli M; Magi A; Gianfaldoni G; Rotunno G; Carrai V; Gelli AM; Valle V; Santini V; Notaro R; Luzzatto L; Bosi A
Cytometry B Clin Cytom; 2013 Mar; 84(2):71-81. PubMed ID: 23281097
[TBL] [Abstract][Full Text] [Related]
16. [Immunophenotyping study on the blood cells of the patients with paroxysmal nocturnal hemoglobinuria].
Chen G; Shao Z; Jia H; Chu Y; Shen D; Zhang Y; Zhang J
Zhonghua Xue Ye Xue Za Zhi; 1997 Apr; 18(4):190-2. PubMed ID: 15622765
[TBL] [Abstract][Full Text] [Related]
17. Reticulocyte-gated flow cytometric analysis of red blood cells in paroxysmal nocturnal hemoglobinuria.
Sato S; Hasegawa Y; Nagasawa T; Ninomiya H
Lab Hematol; 2006; 12(2):82-5. PubMed ID: 16751135
[TBL] [Abstract][Full Text] [Related]
18. Prevalence of paroxysmal nocturnal hemoglobinuria in Chinese patients with Budd-Chiari syndrome or portal vein thrombosis.
Qi X; He C; Han G; Yin Z; Wu F; Zhang Q; Niu J; Wu K; Fan D
J Gastroenterol Hepatol; 2013 Jan; 28(1):148-52. PubMed ID: 23020629
[TBL] [Abstract][Full Text] [Related]
19. Flow cytometric analysis of CD55 and CD59 expression on blood cells in paroxysmal nocturnal haemoglobinuria.
Dworacki G; Sikora J; Mizera-Nyczak E; Trybus M; Mozer-Lisewska I; Czyz A; Zeromski J
Folia Histochem Cytobiol; 2005; 43(2):117-20. PubMed ID: 16044949
[TBL] [Abstract][Full Text] [Related]
20. A simple flow cytometric assay for routine paroxysmal nocturnal hemoglobinuria testing based on immature reticulocytes and granulocytes.
Tsagarakis NJ; Paterakis G
Cytometry B Clin Cytom; 2012 Jul; 82(4):259-63. PubMed ID: 22539359
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]