172 related articles for article (PubMed ID: 15272673)
1. Feasibility of a novel design of high resolution parallax-free Compton enhanced PET scanner dedicated to brain research.
Braem A; Llatas MC; Chesi E; Correia JG; Garibaldi F; Joram C; Mathot S; Nappi E; da Silva MR; Schoenahl F; Séguinot J; Weilhammer P; Zaidi H
Phys Med Biol; 2004 Jun; 49(12):2547-62. PubMed ID: 15272673
[TBL] [Abstract][Full Text] [Related]
2. Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.
Matsumoto K; Kitamura K; Mizuta T; Tanaka K; Yamamoto S; Sakamoto S; Nakamoto Y; Amano M; Murase K; Senda M
J Nucl Med; 2006 Jan; 47(1):83-90. PubMed ID: 16391191
[TBL] [Abstract][Full Text] [Related]
3. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
Habte F; Foudray AM; Olcott PD; Levin CS
Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
[TBL] [Abstract][Full Text] [Related]
4. Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation.
Zhang J; Olcott PD; Chinn G; Foudray AM; Levine CS
Med Phys; 2007 Feb; 34(2):689-702. PubMed ID: 17388187
[TBL] [Abstract][Full Text] [Related]
5. Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arrays.
James SS; Yang Y; Wu Y; Farrell R; Dokhale P; Shah KS; Cherry SR
Phys Med Biol; 2009 Jul; 54(14):4605-19. PubMed ID: 19567945
[TBL] [Abstract][Full Text] [Related]
6. Three-dimensional positron emission tomography imaging with 124I and 86Y.
Vandenberghe S
Nucl Med Commun; 2006 Mar; 27(3):237-45. PubMed ID: 16479243
[TBL] [Abstract][Full Text] [Related]
7. A Prototype High-Resolution Small-Animal PET Scanner Dedicated to Mouse Brain Imaging.
Yang Y; Bec J; Zhou J; Zhang M; Judenhofer MS; Bai X; Di K; Wu Y; Rodriguez M; Dokhale P; Shah KS; Farrell R; Qi J; Cherry SR
J Nucl Med; 2016 Jul; 57(7):1130-5. PubMed ID: 27013696
[TBL] [Abstract][Full Text] [Related]
8. Open-field mouse brain PET: design optimisation and detector characterisation.
Kyme AZ; Judenhofer MS; Gong K; Bec J; Selfridge A; Du J; Qi J; Cherry SR; Meikle SR
Phys Med Biol; 2017 Jul; 62(15):6207-6225. PubMed ID: 28475491
[TBL] [Abstract][Full Text] [Related]
9. Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.
Uzunov N; Bello M; Boccaccio P; Moschini G; Bollini D; de Notaristefani F
Phys Med Biol; 2006 May; 51(9):N199-204. PubMed ID: 16625030
[TBL] [Abstract][Full Text] [Related]
10. Performance evaluation of the ECAT HRRT: an LSO-LYSO double layer high resolution, high sensitivity scanner.
de Jong HW; van Velden FH; Kloet RW; Buijs FL; Boellaard R; Lammertsma AA
Phys Med Biol; 2007 Mar; 52(5):1505-26. PubMed ID: 17301468
[TBL] [Abstract][Full Text] [Related]
11. A position sensitive gamma-ray scintillator detector with enhanced spatial resolution, linearity, and field of view.
Domingo-Pardo C; Goel N; Engert T; Gerl J; Isaka M; Kojouharov I; Schaffner H
IEEE Trans Med Imaging; 2009 Dec; 28(12):2007-14. PubMed ID: 19628451
[TBL] [Abstract][Full Text] [Related]
12. A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept.
Zhang Y; Yan H; Baghaei H; Wong WH
Phys Med Biol; 2016 Feb; 61(4):1608-33. PubMed ID: 26836144
[TBL] [Abstract][Full Text] [Related]
13. Clear-PEM: a dedicated PET camera for improved breast cancer detection.
Abreu MC; Almeida P; Balau F; Ferreira NC; Fetal S; Fraga F; Martins M; Matela N; Moura R; Ortigão C; Peralta L; Rato P; Ribeiro R; Rodrigues P; Santos AI; Trindade A; Varela J
Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):208-10. PubMed ID: 16604628
[TBL] [Abstract][Full Text] [Related]
14. Imaging characteristics of a 3-dimensional GSO whole-body PET camera.
Surti S; Karp JS
J Nucl Med; 2004 Jun; 45(6):1040-9. PubMed ID: 15181139
[TBL] [Abstract][Full Text] [Related]
15. The influence of photon depth of interaction and non-collinear spread of annihilation photons on PET image spatial resolution.
Sánchez-Crespo A; Larsson SA
Eur J Nucl Med Mol Imaging; 2006 Aug; 33(8):940-7. PubMed ID: 16568208
[TBL] [Abstract][Full Text] [Related]
16. Imaging performance of A-PET: a small animal PET camera.
Surti S; Karp JS; Perkins AE; Cardi CA; Daube-Witherspoon ME; Kuhn A; Muehllehner G
IEEE Trans Med Imaging; 2005 Jul; 24(7):844-52. PubMed ID: 16011313
[TBL] [Abstract][Full Text] [Related]
17. Image quality assessment of LaBr3-based whole-body 3D PET scanners: a Monte Carlo evaluation.
Surti S; Karp JS; Muehllehner G
Phys Med Biol; 2004 Oct; 49(19):4593-610. PubMed ID: 15552419
[TBL] [Abstract][Full Text] [Related]
18. Preliminary study on potential of the jPET-D4 human brain scanner for small animal imaging.
Yamaya T; Yoshida E; Toramatsu C; Nishimura M; Shimada Y; Inadama N; Shibuya K; Nishikido F; Murayama H
Ann Nucl Med; 2009 Feb; 23(2):183-90. PubMed ID: 19225942
[TBL] [Abstract][Full Text] [Related]
19. Investigation of spatial resolution improvement by use of a mouth-insert detector in the helmet PET scanner.
Ahmed AM; Tashima H; Yamaya T
Radiol Phys Technol; 2018 Mar; 11(1):7-12. PubMed ID: 28986818
[TBL] [Abstract][Full Text] [Related]
20. Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes.
Yang Y; Dokhale PA; Silverman RW; Shah KS; McClish MA; Farrell R; Entine G; Cherry SR
Phys Med Biol; 2006 May; 51(9):2131-42. PubMed ID: 16625031
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]