323 related articles for article (PubMed ID: 15275743)
1. MLC leaf width impact on the clinical dose distribution: a Monte Carlo approach.
Leal A; Sánchez-Doblado F; Arráns R; Capote R; Lagares JI; Pavón EC; Roselló J
Int J Radiat Oncol Biol Phys; 2004 Aug; 59(5):1548-59. PubMed ID: 15275743
[TBL] [Abstract][Full Text] [Related]
2. Intensity modulated radiation therapy with multileaf collimators of different leaf widths: a comparison of achievable dose distributions.
Nill S; Tücking T; Münter MW; Oelfke U
Radiother Oncol; 2005 Apr; 75(1):106-11. PubMed ID: 15878108
[TBL] [Abstract][Full Text] [Related]
3. Impact of IMRT and leaf width on stereotactic body radiotherapy of liver and lung lesions.
Dvorak P; Georg D; Bogner J; Kroupa B; Dieckmann K; Pötter R
Int J Radiat Oncol Biol Phys; 2005 Apr; 61(5):1572-81. PubMed ID: 15817364
[TBL] [Abstract][Full Text] [Related]
4. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
Sikora M; Dohm O; Alber M
Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
[TBL] [Abstract][Full Text] [Related]
5. Effect of MLC leaf width and PTV margin on the treatment planning of intensity-modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT).
Chang J; Yenice KM; Jiang K; Hunt M; Narayana A
Med Dosim; 2009; 34(2):110-6. PubMed ID: 19410139
[TBL] [Abstract][Full Text] [Related]
6. Effects of multileaf collimator parameters on treatment planning of intensity-modulated radiotherapy.
Wu VW
Med Dosim; 2007; 32(1):38-43. PubMed ID: 17317534
[TBL] [Abstract][Full Text] [Related]
7. The importance of accurate linear accelerator head modelling for IMRT Monte Carlo calculations.
Reynaert N; Coghe M; De Smedt B; Paelinck L; Vanderstraeten B; De Gersem W; Van Duyse B; De Wagter C; De Neve W; Thierens H
Phys Med Biol; 2005 Mar; 50(5):831-46. PubMed ID: 15798258
[TBL] [Abstract][Full Text] [Related]
8. Optimizing leaf widths for a multileaf collimator.
Cui W; Dai J
Phys Med Biol; 2009 May; 54(10):3051-62. PubMed ID: 19398815
[TBL] [Abstract][Full Text] [Related]
9. Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.
Mavroidis P; Ferreira BC; Shi C; Lind BK; Papanikolaou N
Phys Med Biol; 2007 Jul; 52(13):3817-36. PubMed ID: 17664579
[TBL] [Abstract][Full Text] [Related]
10. Radiotherapy of prostate cancer with multileaf collimators (MLCs) optimization of the undulating dose distribution at the MLC edge.
Koelbl O; Schwab F; Bratengeier K; Vordermark D; Flentje M
Strahlenther Onkol; 2005 Feb; 181(2):108-12. PubMed ID: 15702299
[TBL] [Abstract][Full Text] [Related]
11. Influence of the linac design on intensity-modulated radiotherapy of head-and-neck plans.
Topolnjak R; van der Heide UA; Meijer GJ; van Asselen B; Raaijmakers CP; Lagendijk JJ
Phys Med Biol; 2007 Jan; 52(1):169-82. PubMed ID: 17183134
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric evaluation and clinical application of virtual mini-multileaf collimator.
Cheng CW; Wong JR; Ndlovu AM; Das IJ; Schiff P; Uematsu M
Am J Clin Oncol; 2003 Jun; 26(3):e37-44. PubMed ID: 12796614
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID.
Mohammadi M; Bezak E
Phys Med Biol; 2007 Jan; 52(1):N21-33. PubMed ID: 17183123
[TBL] [Abstract][Full Text] [Related]
14. Dosimetric assessment of the field abutment region in head and neck treatments using a multileaf collimator.
Abdel-Hakim K; Nishimura T; Takaih M; Suzuki S; Sakahara H
Strahlenther Onkol; 2003 May; 179(5):312-9. PubMed ID: 12740658
[TBL] [Abstract][Full Text] [Related]
15. IMRT head and neck treatment planning with a commercially available Monte Carlo based planning system.
Boudreau C; Heath E; Seuntjens J; Ballivy O; Parker W
Phys Med Biol; 2005 Mar; 50(5):879-90. PubMed ID: 15798262
[TBL] [Abstract][Full Text] [Related]
16. Dosimetric study using different leaf-width MLCs for treatment planning of dynamic conformal arcs and intensity-modulated radiosurgery.
Jin JY; Yin FF; Ryu S; Ajlouni M; Kim JH
Med Phys; 2005 Feb; 32(2):405-11. PubMed ID: 15789586
[TBL] [Abstract][Full Text] [Related]
17. The dosimetric impact of leaf interdigitation and leaf width on VMAT treatment planning in Pinnacle: comparing Pareto fronts.
van Kesteren Z; Janssen TM; Damen E; van Vliet-Vroegindeweij C
Phys Med Biol; 2012 May; 57(10):2943-52. PubMed ID: 22516969
[TBL] [Abstract][Full Text] [Related]
18. Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer.
Yang J; Li J; Chen L; Price R; McNeeley S; Qin L; Wang L; Xiong W; Ma CM
Phys Med Biol; 2005 Mar; 50(5):869-78. PubMed ID: 15798261
[TBL] [Abstract][Full Text] [Related]
19. Characterization of an extendable multi-leaf collimator for clinical electron beams.
O'Shea TP; Ge Y; Foley MJ; Faddegon BA
Phys Med Biol; 2011 Dec; 56(23):7621-38. PubMed ID: 22086242
[TBL] [Abstract][Full Text] [Related]
20. Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method.
Titt U; Zheng Y; Vassiliev ON; Newhauser WD
Phys Med Biol; 2008 Jan; 53(2):487-504. PubMed ID: 18185001
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]