BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

324 related articles for article (PubMed ID: 15280974)

  • 1. Use of self-expandable plastic stents for the treatment of esophageal perforations and symptomatic anastomotic leaks.
    Gelbmann CM; Ratiu NL; Rath HC; Rogler G; Lock G; Schölmerich J; Kullmann F
    Endoscopy; 2004 Aug; 36(8):695-9. PubMed ID: 15280974
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Management of postoperative esophageal leaks with the Polyflex self-expanding covered plastic stent.
    Langer FB; Wenzl E; Prager G; Salat A; Miholic J; Mang T; Zacherl J
    Ann Thorac Surg; 2005 Feb; 79(2):398-403; discussion 404. PubMed ID: 15680802
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Management of esophageal anastomotic leaks, perforations, and fistulae with self-expanding plastic stents.
    Dai Y; Chopra SS; Kneif S; Hünerbein M
    J Thorac Cardiovasc Surg; 2011 May; 141(5):1213-7. PubMed ID: 21167516
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nonoperative treatment of 15 benign esophageal perforations with self-expandable covered metal stents.
    Fischer A; Thomusch O; Benz S; von Dobschuetz E; Baier P; Hopt UT
    Ann Thorac Surg; 2006 Feb; 81(2):467-72. PubMed ID: 16427833
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Postoperative esophageal leak management with the Polyflex esophageal stent.
    Freeman RK; Ascioti AJ; Wozniak TC
    J Thorac Cardiovasc Surg; 2007 Feb; 133(2):333-8. PubMed ID: 17258558
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Treatment of upper gastrointestinal leaks with a removable, covered, self-expanding metallic stent.
    Babor R; Talbot M; Tyndal A
    Surg Laparosc Endosc Percutan Tech; 2009 Feb; 19(1):e1-4. PubMed ID: 19238047
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Utility of removable esophageal covered self-expanding metal stents for leak and fistula management.
    Blackmon SH; Santora R; Schwarz P; Barroso A; Dunkin BJ
    Ann Thorac Surg; 2010 Mar; 89(3):931-6; discussion 936-7. PubMed ID: 20172156
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Treatment of oesophageal anastomotic leaks by temporary stenting with self-expanding plastic stents.
    Dai YY; Gretschel S; Dudeck O; Rau B; Schlag PM; Hünerbein M
    Br J Surg; 2009 Aug; 96(8):887-91. PubMed ID: 19591167
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Self-expandable metal stents for the treatment of benign upper GI leaks and perforations.
    Swinnen J; Eisendrath P; Rigaux J; Kahegeshe L; Lemmers A; Le Moine O; Devière J
    Gastrointest Endosc; 2011 May; 73(5):890-9. PubMed ID: 21521563
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Implantation of a colorectal stent as a therapeutic approach in the treatment of esophageal leakage.
    Scharf JG; Ramadori G; Becker H; Müller A
    BMC Gastroenterol; 2007 Mar; 7():10. PubMed ID: 17367525
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The role of esophageal stents in the management of esophageal anastomotic leaks and benign esophageal perforations.
    Dasari BV; Neely D; Kennedy A; Spence G; Rice P; Mackle E; Epanomeritakis E
    Ann Surg; 2014 May; 259(5):852-60. PubMed ID: 24509201
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Polyflex expandable stents in the treatment of esophageal disease: initial experience.
    Pennathur A; Chang AC; McGrath KM; Steiner G; Alvelo-Rivera M; Awais O; Gooding WE; Christie NA; Gilbert S; Landreneau RJ; Luketich JD
    Ann Thorac Surg; 2008 Jun; 85(6):1968-72; discussion 1973. PubMed ID: 18498804
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Successful sealing of benign esophageal leaks after temporary placement of a self-expanding plastic stent without fluoroscopic guidance.
    Radecke K; Lang H; Frilling A; Gerken G; Treichel U
    Z Gastroenterol; 2006 Oct; 44(10):1031-8. PubMed ID: 17063431
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Short-term esophageal stenting in the management of benign perforations.
    van Heel NC; Haringsma J; Spaander MC; Bruno MJ; Kuipers EJ
    Am J Gastroenterol; 2010 Jul; 105(7):1515-20. PubMed ID: 20234349
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Novel removable internally fully covered self-expanding metal esophageal stent: feasibility, technique of removal, and tissue response in humans.
    Eloubeidi MA; Lopes TL
    Am J Gastroenterol; 2009 Jun; 104(6):1374-81. PubMed ID: 19491851
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Risk of stent-related aortic erosion after endoscopic stent insertion for intrathoracic anastomotic leaks after esophagectomy.
    Schweigert M; Dubecz A; Stadlhuber RJ; Muschweck H; Stein HJ
    Ann Thorac Surg; 2011 Aug; 92(2):513-8. PubMed ID: 21592460
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Palliative treatment of esophageal carcinoma with self-expanding plastic stents: a report on 69 cases.
    Szegedi L; Gál I; Kósa I; Kiss GG
    Eur J Gastroenterol Hepatol; 2006 Nov; 18(11):1197-201. PubMed ID: 17033441
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Endoscopic treatment of mediastinal anastomotic leaks].
    Schubert D; Pross M; Nestler G; Ptok H; Scheidbach H; Fahlke J; Lippert H
    Zentralbl Chir; 2006 Oct; 131(5):369-75. PubMed ID: 17089284
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A randomized prospective comparison of self-expandable plastic stents and partially covered self-expandable metal stents in the palliation of malignant esophageal dysphagia.
    Conio M; Repici A; Battaglia G; De Pretis G; Ghezzo L; Bittinger M; Messmann H; Demarquay JF; Blanchi S; Togni M; Conigliaro R; Filiberti R
    Am J Gastroenterol; 2007 Dec; 102(12):2667-77. PubMed ID: 18042102
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Removable self-expanding plastic esophageal stent as a continuous, non-permanent dilator in treating refractory benign esophageal strictures: a prospective two-center study.
    Dua KS; Vleggaar FP; Santharam R; Siersema PD
    Am J Gastroenterol; 2008 Dec; 103(12):2988-94. PubMed ID: 18786110
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.