BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 15282426)

  • 1. Comparison of safety and efficacy between first and second generation of angio-seal closure devices in interventional patients.
    Lasic Z; Mehran R; Dangas G; Mintz G; Nikolsky E; Tsounias E; Udani PC; Adamian M; Adamian J; Moussa I; Collins M; Stone G; Moses J
    J Invasive Cardiol; 2004 Jul; 16(7):356-8. PubMed ID: 15282426
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rapid hemostasis of arterial puncture sites with Angio-Seal in patients undergoing percutaneous coronary intervention.
    Trisnohadi HB
    Acta Med Indones; 2005; 37(2):87-90. PubMed ID: 20066791
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A randomized trial comparing compression, Perclose Proglide and Angio-Seal VIP for arterial closure following percutaneous coronary intervention: the CAP trial.
    Martin JL; Pratsos A; Magargee E; Mayhew K; Pensyl C; Nunn M; Day F; Shapiro T
    Catheter Cardiovasc Interv; 2008 Jan; 71(1):1-5. PubMed ID: 18098171
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prospective nonrandomized trial of manual compression and Angio-Seal and Starclose arterial closure devices in common femoral punctures.
    Ratnam LA; Raja J; Munneke GJ; Morgan RA; Belli AM
    Cardiovasc Intervent Radiol; 2007; 30(2):182-8. PubMed ID: 17200896
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of costs and safety of a suture-mediated closure device with conventional manual compression after coronary artery interventions.
    Rickli H; Unterweger M; Sütsch G; Brunner-La Rocca HP; Sagmeister M; Ammann P; Amann FW
    Catheter Cardiovasc Interv; 2002 Nov; 57(3):297-302. PubMed ID: 12410501
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The safety and efficacy of "pre-closure" utilizing the Closer suture-mediated vascular closure device for achievement of hemostasis in patients following coronary interventions: results of the second Perclose Accelerated Ambulation and Discharge (PARADISE II) Trial.
    Nasu K; Tsuchikane E; Sumitsuji S; Tsuji T; Tamai H
    J Invasive Cardiol; 2005 Jan; 17(1):30-3. PubMed ID: 15640537
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A randomised controlled trial comparing the routine use of an Angio-Seal STS device strategy with conventional femoral haemostasis methods in a district general hospital.
    Behan MW; Large JK; Patel NR; Lloyd GW; Sulke AN
    Int J Clin Pract; 2007 Mar; 61(3):367-72. PubMed ID: 17313602
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy of a novel procedure sheath and closure device during diagnostic catheterization: the multicenter randomized clinical trial of the FISH device.
    Bavry AA; Raymond RE; Bhatt DL; Chambers CE; DeNardo AJ; Hermiller JB; Myers PR; Pitts DE; Scott JA; Savader SJ; Steinhubl S
    J Invasive Cardiol; 2008 Apr; 20(4):152-6. PubMed ID: 18398227
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical effectiveness of the Prostar XL suture-mediated percutaneous vascular closure device following PCI: results of the Perclose AcceleRated Ambulation and DISchargE (PARADISE) Trial.
    Nasu K; Tsuchikane E; Sumitsuji S;
    J Invasive Cardiol; 2003 May; 15(5):251-6. PubMed ID: 12730632
    [TBL] [Abstract][Full Text] [Related]  

  • 10. On-site immediate removal of intraortic balloon pump after high-risk percutaneous intervention with a 6 F closure suture device with the "preclosure" technique.
    Lozano I; Avanzas P; Moris C
    Catheter Cardiovasc Interv; 2007 Oct; 70(4):538-40. PubMed ID: 17896399
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Closure of the femoral artery after cardiac catheterization: a comparison of Angio-Seal, StarClose, and manual compression.
    Deuling JH; Vermeulen RP; Anthonio RA; van den Heuvel AF; Jaarsma T; Jessurun G; de Smet BJ; Tan ES; Zijlstra F
    Catheter Cardiovasc Interv; 2008 Mar; 71(4):518-23. PubMed ID: 18307223
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Immediate hemostasis of the femoral artery after heart catheterization: the present situation of closure systems].
    Lochow P; Silber S
    Dtsch Med Wochenschr; 2004 Aug; 129(33):1753-8. PubMed ID: 15295687
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Vascular complications with newer generations of angioseal vascular closure devices.
    Applegate RJ; Sacrinty M; Kutcher MA; Gandhi SK; Baki TT; Santos RM; Little WC
    J Interv Cardiol; 2006 Feb; 19(1):67-74. PubMed ID: 16483343
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Treatment of an Angio-Seal-related vascular complication using the SilverHawk plaque excision system: a case report.
    Lee JH; Biring TS; Gimelli G
    Catheter Cardiovasc Interv; 2007 Jan; 69(1):141-5. PubMed ID: 17139652
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A meta-analysis of percutaneous vascular closure devices after diagnostic catheterization and percutaneous coronary intervention.
    Vaitkus PT
    J Invasive Cardiol; 2004 May; 16(5):243-6. PubMed ID: 15152128
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safety and efficacy of staple-mediated femoral arteriotomy closure: results from a randomized multicenter study.
    Ansel G; Yakubov S; Neilsen C; Allie D; Stoler R; Hall P; Fail P; Sanborn T; Caputo RP
    Catheter Cardiovasc Interv; 2006 Apr; 67(4):546-53. PubMed ID: 16538688
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The safety and efficacy of the Angio-Seal closure device in diagnostic and interventional neuroangiography setting: a single-center experience with 1,443 closures.
    Geyik S; Yavuz K; Akgoz A; Koc O; Peynircioglu B; Cil B; Cekirge S; Saatci I
    Neuroradiology; 2007 Sep; 49(9):739-46. PubMed ID: 17594084
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Vascular complications after hemostatic puncture closure device (Angio-Seal) are not higher in overweight patients.
    Wong P; Harding S; Walters D; Hull ML; Jang IK
    J Invasive Cardiol; 2001 Sep; 13(9):623-5. PubMed ID: 11533497
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effectiveness and complications of vascular access closure devices after interventional procedures.
    Sesana M; Vaghetti M; Albiero R; Corvaja N; Martini G; Sivieri G; Colombo A
    J Invasive Cardiol; 2000 Aug; 12(8):395-9. PubMed ID: 10953101
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Initial experience of removal of 10-French sheaths using the 8-French Angio-Seal vascular closure device.
    Fallahi A; Kim M
    J Invasive Cardiol; 2010 Mar; 22(3):130-1. PubMed ID: 20197581
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.