BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 15296397)

  • 1. Determination of iodide in seawater and edible salt by microcolumn liquid chromatography with poly(ethylene glycol) stationary phase.
    Rong L; Takeuchi T
    J Chromatogr A; 2004 Jul; 1042(1-2):131-5. PubMed ID: 15296397
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of iodide in seawater samples by ion chromatography with chemically-bonded poly(ethylene glycol) stationary phase.
    Rong L; Lim LW; Takeuchi T
    J Chromatogr A; 2006 Sep; 1128(1-2):68-72. PubMed ID: 16837001
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of iodide in seawater using C30 column modified with polyoxyethylene oleyl ether in ion chromatography.
    Rong L; Lim LW; Takeuchi T
    Talanta; 2007 Jul; 72(5):1625-9. PubMed ID: 19071807
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of iodide in seawater by capillary ion chromatography using hexadimethrine bromide modified C30 stationary phases.
    Rong L; Lim LW; Takeuchi T
    Anal Sci; 2013; 29(1):31-4. PubMed ID: 23303081
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid and direct determination of iodide in seawater by electrostatic ion chromatography.
    Hu W; Yang PJ; Hasebe K; Haddad PR; Tanaka K
    J Chromatogr A; 2002 May; 956(1-2):103-7. PubMed ID: 12108640
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Poly(ethylene oxide)-bonded stationary phase for separation of inorganic anions in capillary ion chromatography.
    Linda R; Lim LW; Takeuchi T
    J Chromatogr A; 2013 Jun; 1294():117-21. PubMed ID: 23659983
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Poly(ethylene glycol) Methyl Ether Methacrylate-bonded Stationary Phase in Ion Chromatography and Its Application to Seawater Samples.
    Rong L; Lim LW; Takeuchi T
    Anal Sci; 2021 Jul; 37(7):1003-1006. PubMed ID: 33310989
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Trace ion analysis of seawater by capillary electrophoresis: determination of iodide using transient isotachophoretic preconcentration.
    Hirokawa T; Ichihara T; Ito K; Timerbaev AR
    Electrophoresis; 2003 Jul; 24(14):2328-34. PubMed ID: 12874867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Creation and characteristics of phosphatidylcholine stationary phases for the chromatographic separation of inorganic anions.
    Hu W; Haddad PR; Tanaka K; Mori M; Tekura K; Hasebe K; Ohno M; Kamo N
    J Chromatogr A; 2003 May; 997(1-2):237-42. PubMed ID: 12830897
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Polyoxyethylene as the stationary phase in ion chromatography.
    Lim LW; Rong L; Takeuchi T
    Anal Sci; 2012; 28(3):205-13. PubMed ID: 22451358
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Flow gradient liquid chromatography using a coated anion exchange microcolumn.
    Nesterenko EP; Barron LP; Nesterenko PN; Paull B
    J Sep Sci; 2006 Feb; 29(2):228-35. PubMed ID: 16524096
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Catalytic spectrophotometric determination of iodide in pharmaceutical preparations and edible salt.
    El-Ries MA; Khaled E; Zidane FI; Ibrahim SA; Abd-Elmonem MS
    Drug Test Anal; 2012 Feb; 4(2):129-35. PubMed ID: 21381219
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Separation of inorganic anions by liquid chromatography with crown ether as eluent additive.
    Takeuchi T; Lim LW
    Anal Sci; 2011; 27(10):1019-23. PubMed ID: 21985926
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of eluent composition on retention behavior of anions in ion chromatography on anion-exchangers modified with heparin.
    Safni ; Takeuchi T; Miwa T; Hashimoto Y; Moriyama H
    J Chromatogr A; 1999 Jul; 850(1-2):65-72. PubMed ID: 10457466
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fast and simple method for determination of iodide in human urine, serum, sea water, and cooking salt by capillary zone electrophoresis.
    Pantůcková P; Krivánková L
    Electrophoresis; 2004 Apr; 25(7-8):1102-10. PubMed ID: 15095453
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of nitrite, nitrate, bromide, and iodide in seawater by ion chromatography with UV detection using dilauryldimethylammonium-coated monolithic ODS columns and sodium chloride as an eluent.
    Ito K; Nomura R; Fujii T; Tanaka M; Tsumura T; Shibata H; Hirokawa T
    Anal Bioanal Chem; 2012 Nov; 404(8):2513-7. PubMed ID: 22986989
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simple and rapid determination of iodide in table salt by stripping potentiometry at a carbon-paste electrode.
    Svancara I; Ogorevc B; Nović M; Vytras K
    Anal Bioanal Chem; 2002 Apr; 372(7-8):795-800. PubMed ID: 12012191
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Vitamin U-bonded stationary phase in capillary ion chromatography.
    Jiang XL; Lim LW; Takeuchi T
    Anal Sci; 2011; 27(12):1203-6. PubMed ID: 22156247
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Separation of inorganic anions on hydrophobic stationary phases in ion chromatography.
    Takeuchi T; Jiang B; Lim LW
    Anal Bioanal Chem; 2012 Jan; 402(1):551-5. PubMed ID: 21877187
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Capillary zone electrophoretic determination of iodide in seawater using transient isotachophoresis with artificial seawater as the background electrolyte.
    Yokota K; Fukushi K; Ishio N; Sasayama N; Nakayama Y; Takeda S; Wakida SI
    Electrophoresis; 2003 Jun; 24(12-13):2244-2251. PubMed ID: 12858397
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.