97 related articles for article (PubMed ID: 1529880)
1. Early and late outcome following deployment of a new flexible tantalum intracoronary stent in dogs.
Muhlestein JB; Phillips HR; Quigley PJ; Bauman RP; Gammon RS; Chapman GD; Mikat EM; Palmos LE; Overman AB; Stack RS
Am Heart J; 1992 Oct; 124(4):1058-67. PubMed ID: 1529880
[TBL] [Abstract][Full Text] [Related]
2. A new expandable intracoronary tantalum (Strecker) stent: early experimental results and follow-up to twelve months.
Ribeiro PA; Gallo R; Antonius J; Mimish L; Sriram R; Bianchi S; Duran CG
Am Heart J; 1993 Feb; 125(2 Pt 1):501-10. PubMed ID: 8427147
[TBL] [Abstract][Full Text] [Related]
3. A new balloon-expandable tantalum coil stent: angiographic patency and histologic findings in an atherogenic swine model.
White CJ; Ramee SR; Banks AK; Mesa JE; Chokshi S; Isner JM
J Am Coll Cardiol; 1992 Mar; 19(4):870-6. PubMed ID: 1545083
[TBL] [Abstract][Full Text] [Related]
4. Restenosis following placement of an intracoronary heparin treated tantulum stent in the hyperlipidemic miniature swine model.
Jenkins JS; Webel R; Laughlin MH; Rowland SM; Yoklavich MF; Amann JF; Branson K; Myers PR
J Invasive Cardiol; 1995; 7(6):173-82. PubMed ID: 10155102
[TBL] [Abstract][Full Text] [Related]
5. Placement and angiographic patency of the Strecker coronary stent.
Laird JR; Carter AJ; Kufs WM; Farb A; Prewitt KC; Wortham DC
Cathet Cardiovasc Diagn; 1994 Apr; 31(4):322-9. PubMed ID: 8055575
[TBL] [Abstract][Full Text] [Related]
6. Coronary stenting with a new ultra-short balloon expandable device: early and late animal results.
Anwar A; Stertzer SH; Hidalgo BO; de la Fuente L; Morales MC; Fischer EI; Shaw RE; Murphy MC; Myler RK
Cathet Cardiovasc Diagn; 1994 Jan; 31(1):85-9. PubMed ID: 8118865
[TBL] [Abstract][Full Text] [Related]
7. Self-expandable and highly flexible nitinol stent: immediate and long-term results in dogs.
Grenadier E; Shofti R; Beyar M; Lichtig H; Mordechowitz D; Globerman O; Markiewicz W; Beyar R
Am Heart J; 1994 Nov; 128(5):870-8. PubMed ID: 7942477
[TBL] [Abstract][Full Text] [Related]
8. Angiographic follow-up and clinical experience with the flexible Tantalum Cordis stent.
Watson PS; Ponde CK; Aroney CN; Cameron J; Cannon A; Dooris M; Garrahy PJ; McEniery PT; Bett JH
Cathet Cardiovasc Diagn; 1998 Feb; 43(2):168-73. PubMed ID: 9488549
[TBL] [Abstract][Full Text] [Related]
9. Covered stents for prevention of restenosis. Experimental and clinical results with different stent designs.
Tepe G; Duda SH; Hanke H; Schulze S; Hagmeier S; Bruck B; Schott U; Betz E; Schmahl FW; Claussen CD
Invest Radiol; 1996 Apr; 31(4):223-9. PubMed ID: 8721962
[TBL] [Abstract][Full Text] [Related]
10. Balloon-expandable intracoronary stents in the adult dog.
Schatz RA; Palmaz JC; Tio FO; Garcia F; Garcia O; Reuter SR
Circulation; 1987 Aug; 76(2):450-7. PubMed ID: 2955956
[TBL] [Abstract][Full Text] [Related]
11. Comparison of the vascular responses to balloon-expandable stenting in the coronary and peripheral circulations: long-term results in an animal model using the TriMaxx stent.
Dubé H; Clifford AG; Barry CM; Schwarten DE; Schwartz LB
J Vasc Surg; 2007 Apr; 45(4):821-7. PubMed ID: 17398392
[TBL] [Abstract][Full Text] [Related]
12. Coronary stenting with a new, radiopaque, balloon-expandable endoprosthesis in pigs.
van der Giessen WJ; Serruys PW; van Beusekom HM; van Woerkens LJ; van Loon H; Soei LK; Strauss BH; Beatt KJ; Verdouw PD
Circulation; 1991 May; 83(5):1788-98. PubMed ID: 2022030
[TBL] [Abstract][Full Text] [Related]
13. Arterial stenting with self-expandable and balloon-expandable endoprostheses.
van der Giessen WJ; Serruys PW; van Woerkens LJ; Beatt KJ; Visser WJ; Jongkind JF; van Bremen RH; Ridderhof E; van Loon H; Soei LK
Int J Card Imaging; 1990; 5(2-3):163-71. PubMed ID: 2230294
[TBL] [Abstract][Full Text] [Related]
14. Percutaneous polymeric stents in porcine coronary arteries. Initial experience with polyethylene terephthalate stents.
Murphy JG; Schwartz RS; Edwards WD; Camrud AR; Vlietstra RE; Holmes DR
Circulation; 1992 Nov; 86(5):1596-604. PubMed ID: 1423971
[TBL] [Abstract][Full Text] [Related]
15. Long-term intracoronary stent placement: arteriographic and histologic results after 7 years in a dog model.
Robinson KA; Roubin GS; King SB
Cathet Cardiovasc Diagn; 1996 May; 38(1):32-7. PubMed ID: 8722855
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of a second-generation tantalum biliary stent in a canine model.
Cardella JF; Wilson RP; Fox PS; Griffith JW
J Vasc Interv Radiol; 1995; 6(3):397-403. PubMed ID: 7647441
[TBL] [Abstract][Full Text] [Related]
17. Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries.
Hårdhammar PA; van Beusekom HM; Emanuelsson HU; Hofma SH; Albertsson PA; Verdouw PD; Boersma E; Serruys PW; van der Giessen WJ
Circulation; 1996 Feb; 93(3):423-30. PubMed ID: 8565158
[TBL] [Abstract][Full Text] [Related]
18. Flexible tantalum stents implanted in aortas and iliac arteries: effects in normal canines.
Barth KH; Virmani R; Strecker EP; Savin MA; Lindisch D; Matsumoto AH; Teitelbaum GP
Radiology; 1990 Apr; 175(1):91-6. PubMed ID: 2315508
[TBL] [Abstract][Full Text] [Related]
19. Coronary lumen at six-month follow-up of a new radiopaque Cordis tantalum stent using quantitative angiography and intracoronary ultrasound.
Ozaki Y; Keane D; Nobuyoshi M; Hamasaki N; Popma JJ; Serruys PW
Am J Cardiol; 1995 Dec; 76(16):1135-43. PubMed ID: 7484898
[TBL] [Abstract][Full Text] [Related]
20. Low-molecular-weight heparin reduces neointimal proliferation after coronary stent implantation in hypercholesterolemic minipigs.
Buchwald AB; Unterberg C; Nebendahl K; Gröne HJ; Wiegand V
Circulation; 1992 Aug; 86(2):531-7. PubMed ID: 1322255
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]