139 related articles for article (PubMed ID: 15305467)
1. A practical approach to prevent gantry-couch collision for linac-based radiosurgery.
Hua C; Chang J; Yenice K; Chan M; Amols H
Med Phys; 2004 Jul; 31(7):2128-34. PubMed ID: 15305467
[TBL] [Abstract][Full Text] [Related]
2. Collision prediction for intracranial stereotactic radiosurgery planning: An easy-to-implement analytical solution.
Felefly T; Achkar S; Khater N; Sayah R; Fares G; Farah N; El Barouky J; Azoury F; El Khoury C; Roukoz C; Nehme Nasr D; Nasr E
Cancer Radiother; 2020 Jul; 24(4):316-322. PubMed ID: 32467083
[TBL] [Abstract][Full Text] [Related]
3. The development and verification of a highly accurate collision prediction model for automated noncoplanar plan delivery.
Yu VY; Tran A; Nguyen D; Cao M; Ruan D; Low DA; Sheng K
Med Phys; 2015 Nov; 42(11):6457-67. PubMed ID: 26520735
[TBL] [Abstract][Full Text] [Related]
4. Development and clinical implementation of eclipse scripting-based automated patient-specific collision avoidance software.
Mann TD; Ploquin NP; Gill WR; Thind KS
J Appl Clin Med Phys; 2019 Sep; 20(9):12-19. PubMed ID: 31282083
[TBL] [Abstract][Full Text] [Related]
5. Prediction of conical collimator collision for stereotactic radiosurgery.
Park J; McDermott R; Kim S; Huq MS
J Appl Clin Med Phys; 2020 Sep; 21(9):39-46. PubMed ID: 32627949
[TBL] [Abstract][Full Text] [Related]
6. A clinically feasible method for the detection of potential collision in proton therapy.
Zou W; Lin H; Plastaras JP; Wang H; Bui V; Vapiwala N; McDonough J; Tochner Z; Both S
Med Phys; 2012 Nov; 39(11):7094-101. PubMed ID: 23127100
[TBL] [Abstract][Full Text] [Related]
7. Technical note: Comprehensive evaluations of gantry and couch rotation isocentricities for implementing proton stereotactic radiosurgery.
Shen J; Robertson DG; Bues M; Shipulin K; Liu W; Stoker J; Ashman JB; Lara P; Keole SR; Wong W; Vora SA
Med Phys; 2023 Jun; 50(6):3359-3367. PubMed ID: 36959772
[TBL] [Abstract][Full Text] [Related]
8. An open-source tool to visualize potential cone collisions while planning SRS cases.
Licon AL; Alexandrian A; Saenz D; Myers P; Rasmussen K; Stathakis S; Papanikolaou N; Kirby N
J Appl Clin Med Phys; 2020 Oct; 21(10):40-47. PubMed ID: 32779832
[TBL] [Abstract][Full Text] [Related]
9. Stereotactic radiosurgery with MLC-defined arcs: Verification of dosimetry, spatial accuracy, and end-to-end tests.
Brezovich IA; Wu X; Popple RA; Covington E; Cardan R; Shen S; Fiveash J; Bredel M; Guthrie B
J Appl Clin Med Phys; 2019 May; 20(5):84-98. PubMed ID: 30977297
[TBL] [Abstract][Full Text] [Related]
10. Collision indicator charts for gantry-couch position combinations for Varian linacs.
Becker SJ
J Appl Clin Med Phys; 2011 Mar; 12(3):3405. PubMed ID: 21844849
[TBL] [Abstract][Full Text] [Related]
11. Motion monitoring for cranial frameless stereotactic radiosurgery using video-based three-dimensional optical surface imaging.
Li G; Ballangrud A; Kuo LC; Kang H; Kirov A; Lovelock M; Yamada Y; Mechalakos J; Amols H
Med Phys; 2011 Jul; 38(7):3981-94. PubMed ID: 21858995
[TBL] [Abstract][Full Text] [Related]
12. Clearance assurance for stereotactic radiosurgery and radiotherapy.
Furhang EE; Hanley J; Chiu-Tsao ST; Toner S; Fan P; Gliedman P; Harrison LB
Med Phys; 2002 Jan; 29(1):45-50. PubMed ID: 11831572
[TBL] [Abstract][Full Text] [Related]
13. The measurement of linear accelerator isocenter motion using a three-micrometer device and an adjustable pointer.
Tsai JS; Curran BH; Sternick ES; Engler MJ
Int J Radiat Oncol Biol Phys; 1996 Jan; 34(1):189-95. PubMed ID: 12118550
[TBL] [Abstract][Full Text] [Related]
14. Collision prediction software for radiotherapy treatments.
Padilla L; Pearson EA; Pelizzari CA
Med Phys; 2015 Nov; 42(11):6448-56. PubMed ID: 26520734
[TBL] [Abstract][Full Text] [Related]
15. An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery.
Capaldi DPI; Skinner LB; Dubrowski P; Yu AS
Phys Med Biol; 2020 Jun; 65(11):115006. PubMed ID: 32235050
[TBL] [Abstract][Full Text] [Related]
16. Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery.
Rowshanfarzad P; Sabet M; O'Connor DJ; Greer PB
Med Phys; 2011 Jul; 38(7):3963-70. PubMed ID: 21858993
[TBL] [Abstract][Full Text] [Related]
17. Assessment of an Elekta Versa HD linear accelerator for stereotactic radiosurgery with circular cone collimators.
Zhang M; Fan Q; Lei Y; Thapa B; Padula G
J Xray Sci Technol; 2020; 28(1):71-82. PubMed ID: 31904001
[TBL] [Abstract][Full Text] [Related]
18. A new irradiation unit constructed of self-moving gantry-CT and linac.
Kuriyama K; Onishi H; Sano N; Komiyama T; Aikawa Y; Tateda Y; Araki T; Uematsu M
Int J Radiat Oncol Biol Phys; 2003 Feb; 55(2):428-35. PubMed ID: 12527056
[TBL] [Abstract][Full Text] [Related]
19. Design of a 3D patient-specific collision avoidance virtual framework for half-gantry proton therapy system.
Dougherty JM; Whitaker TJ; Mundy DW; Tryggestad EJ; Beltran CJ
J Appl Clin Med Phys; 2022 Feb; 23(2):e13496. PubMed ID: 34890094
[TBL] [Abstract][Full Text] [Related]
20. An improved method for evaluating LINAC isocenter.
Zacharopoulos NG; Fenyes DA
Med Phys; 2023 May; 50(5):2672-2682. PubMed ID: 36896920
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]