597 related articles for article (PubMed ID: 15308143)
1. Development of real-time thermal neutron monitor using boron-loaded plastic scintillator with optical fiber for boron neutron capture therapy.
Ishikawa M; Ono K; Sakurai Y; Unesaki H; Uritani A; Bengua G; Kobayashi T; Tanaka K; Kosako T
Appl Radiat Isot; 2004 Nov; 61(5):775-9. PubMed ID: 15308143
[TBL] [Abstract][Full Text] [Related]
2. Performance measurement of the scintillator with optical fiber detector for boron neutron capture therapy.
Komeda M; Kumada H; Ishikawa M; Nakamura T; Yamamoto K; Matsumura A
Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S254-7. PubMed ID: 19398347
[TBL] [Abstract][Full Text] [Related]
3. Early clinical experience utilizing scintillator with optical fiber (SOF) detector in clinical boron neutron capture therapy: its issues and solutions.
Ishikawa M; Yamamoto T; Matsumura A; Hiratsuka J; Miyatake S; Kato I; Sakurai Y; Kumada H; Shrestha SJ; Ono K
Radiat Oncol; 2016 Aug; 11(1):105. PubMed ID: 27506665
[TBL] [Abstract][Full Text] [Related]
4. Application of an ultraminiature thermal neutron monitor for irradiation field study of accelerator-based neutron capture therapy.
Ishikawa M; Tanaka K; Endo S; Hoshi M
J Radiat Res; 2015 Mar; 56(2):391-6. PubMed ID: 25589504
[TBL] [Abstract][Full Text] [Related]
5. Calibration of the borated ion chamber at NIST reactor thermal column.
Wang Z; Hertel NE; Lennox A
Radiat Prot Dosimetry; 2007; 126(1-4):626-30. PubMed ID: 17525059
[TBL] [Abstract][Full Text] [Related]
6. Development of a tiny neutron probe with an optical fibre for BNCT.
Ito Y; Katano G; Harano H; Matsumoto T; Uritani A; Kudo K; Kobayashi K; Yoshimoto T; Sakurai Y; Kobayashi T; Mori C
Radiat Prot Dosimetry; 2004; 110(1-4):619-22. PubMed ID: 15353718
[TBL] [Abstract][Full Text] [Related]
7. Development and characteristics of the HANARO neutron irradiation facility for applications in the boron neutron capture therapy field.
Kim MS; Lee BC; Hwang SY; Kim H; Jun BJ
Phys Med Biol; 2007 May; 52(9):2553-66. PubMed ID: 17440252
[TBL] [Abstract][Full Text] [Related]
8. Development of a small scintillation detector with an optical fiber for fast neutrons.
Yagi T; Unesaki H; Misawa T; Pyeon CH; Shiroya S; Matsumoto T; Harano H
Appl Radiat Isot; 2011 Feb; 69(2):539-44. PubMed ID: 21129989
[TBL] [Abstract][Full Text] [Related]
9. New idea of a small-sized neutron detector with a plastic fibre.
Matsumoto T; Harano H; Masuda A; Nishiyama J; Sakurai Y; Uritani A
Radiat Prot Dosimetry; 2011 Jul; 146(1-3):92-5. PubMed ID: 21525042
[TBL] [Abstract][Full Text] [Related]
10. Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments.
Miller ME; Sztejnberg ML; González SJ; Thorp SI; Longhino JM; Estryk G
Med Phys; 2011 Dec; 38(12):6502-12. PubMed ID: 22149833
[TBL] [Abstract][Full Text] [Related]
11. Feasibility study of optical imaging of the boron-dose distribution by a liquid scintillator in a clinical boron neutron capture therapy field.
Maeda H; Nohtomi A; Hu N; Kakino R; Akita K; Ono K
Med Phys; 2024 Jan; 51(1):509-521. PubMed ID: 37672219
[TBL] [Abstract][Full Text] [Related]
12. 'The measurement of thermal neutron flux depression for determining the concentration of boron in blood'--suggestions as to further development of the method.
Bolewski A; Ciechanowski M; Dydejczyk A; Kreft A
Phys Med Biol; 2005 Oct; 50(20):L21-4. PubMed ID: 16204865
[TBL] [Abstract][Full Text] [Related]
13. Moderated 252Cf neutron energy spectra in brain tissue and calculated boron neutron capture dose.
Rivard MJ; Zamenhof RG
Appl Radiat Isot; 2004 Nov; 61(5):753-7. PubMed ID: 15308139
[TBL] [Abstract][Full Text] [Related]
14. An accelerator-based epithermal neutron beam design for BNCT and dosimetric evaluation using a voxel head phantom.
Lee DJ; Han CY; Park SH; Kim JK
Radiat Prot Dosimetry; 2004; 110(1-4):655-60. PubMed ID: 15353726
[TBL] [Abstract][Full Text] [Related]
15. Performance of silicon microdosimetry detectors in boron neutron capture therapy.
Bradley PD; Rosenfeld AB; Allen B; Coderre J; Capala J
Radiat Res; 1999 Mar; 151(3):235-43. PubMed ID: 10073660
[TBL] [Abstract][Full Text] [Related]
16. IMPROVEMENT OF GAMMA-RAY SUBTRACTION PROCEDURE FOR A CURRENT-MODE NEUTRON DETECTOR WITH A PAIR OF 6Li- AND 7Li-GLASS SCINTILLATORS.
Matsumoto T; Masuda A; Harano H; Hori JI; Sano T
Radiat Prot Dosimetry; 2020 Jun; 188(1):117-122. PubMed ID: 31747040
[TBL] [Abstract][Full Text] [Related]
17. Thermal neutron dosimeter by synthetic single crystal diamond devices.
Almaviva S; Marinelli M; Milani E; Prestopino G; Tucciarone A; Verona C; Verona-Rinati G; Angelone M; Pillon M
Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S183-5. PubMed ID: 19375336
[TBL] [Abstract][Full Text] [Related]
18. LVR-15 reactor epithermal neutron beam parameters--results of measurements.
Burian J; Klupak V; Marek M; Rejchrt J; Viererbl L; Gambarini G; Bartesaghi G
Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S202-5. PubMed ID: 19375340
[TBL] [Abstract][Full Text] [Related]
19. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.
Ishikawa M; Nagase N; Matsuura T; Hiratsuka J; Suzuki R; Miyamoto N; Sutherland KL; Fujita K; Shirato H
J Radiat Res; 2015 Mar; 56(2):372-81. PubMed ID: 25618136
[TBL] [Abstract][Full Text] [Related]
20. Toward prompt gamma spectrometry for monitoring boron distributions during extra corporal treatment of liver metastases by boron neutron capture therapy: a Monte Carlo simulation study.
Khelifi R; Nievaart VA; Bode P; Moss RL; Krijger GC
Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S359-61. PubMed ID: 19394243
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]