BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

419 related articles for article (PubMed ID: 15311864)

  • 1. Hemodynamic characterization of calcified stenotic human aortic valves before and after treatment with a novel aortic valve repair system.
    Ohashi KL; Culkar J; Riebman JB; Estes M; Constantz BR; Yoganathan AP
    J Heart Valve Dis; 2004 Jul; 13(4):582-92; discussion 592. PubMed ID: 15311864
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep].
    Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436
    [TBL] [Abstract][Full Text] [Related]  

  • 3. ON-X bileaflet valve in aortic position--early experience shows an improved hemodynamic profile.
    Fraund S; Pethig K; Wahlers T; Harringer W; Wiebe K; Strüber M; Karck M; Mehler D; Haverich A
    Thorac Cardiovasc Surg; 1998 Oct; 46(5):293-7. PubMed ID: 9885121
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mid-term results of freestyle aortic stentless bioprosthetic valve: clinical impact of quantitative analysis of in-vivo three-dimensional flow velocity profile by magnetic resonance imaging.
    Matsue H; Sawa Y; Matsumiya G; Matsuda H; Hamada S
    J Heart Valve Dis; 2005 Sep; 14(5):630-6. PubMed ID: 16245502
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of mechanical and biological aortic valve replacement on coronary perfusion: a prospective, randomized study.
    Bakhtiary F; Abolmaali N; Dzemali O; Wittlinger T; Doss M; Moritz A; Kleine P
    J Heart Valve Dis; 2006 Jan; 15(1):5-11; discussion 11. PubMed ID: 16480006
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The subcoronary Toronto stentless versus supra-annular Perimount stented replacement aortic valve: early clinical and hemodynamic results of a randomized comparison in 160 patients.
    Chambers JB; Rimington HM; Hodson F; Rajani R; Blauth CI
    J Thorac Cardiovasc Surg; 2006 Apr; 131(4):878-2. PubMed ID: 16580447
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Percutaneous aortic valve replacement: resection before implantation.
    Quaden R; Attmann T; Boening A; Cremer J; Lutter G
    Eur J Cardiothorac Surg; 2005 May; 27(5):836-40. PubMed ID: 15848323
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tilting disc versus bileaflet aortic valve substitutes: intraoperative and postoperative hemodynamic performance in humans.
    Kleine P; Hasenkam MJ; Nygaard H; Perthel M; Wesemeyer D; Laas J
    J Heart Valve Dis; 2000 Mar; 9(2):308-11; discussion 311-2. PubMed ID: 10772054
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
    Wagner IM; Eichinger WB; Bleiziffer S; Botzenhardt F; Gebauer I; Guenzinger R; Bauernschmitt R; Lange R
    J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults.
    Zegdi R; Ciobotaru V; Noghin M; Sleilaty G; Lafont A; Latrémouille C; Deloche A; Fabiani JN
    J Am Coll Cardiol; 2008 Feb; 51(5):579-84. PubMed ID: 18237689
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Evaluation of aortic valve replacement involving small severely calcified aortic annulus in elderly patients].
    Iwahashi M; Nishimura Y; Hiramatsu K; Komori S; Shibata M; Yuzaki M; Okamura Y
    Kyobu Geka; 2006 Apr; 59(4):336-9. PubMed ID: 16613154
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel pulse duplicator system: evaluation of different valve prostheses.
    Haaf P; Steiner M; Attmann T; Pfister G; Cremer J; Lutter G
    Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience.
    Cribier A; Eltchaninoff H; Tron C; Bauer F; Agatiello C; Nercolini D; Tapiero S; Litzler PY; Bessou JP; Babaliaros V
    J Am Coll Cardiol; 2006 Mar; 47(6):1214-23. PubMed ID: 16545654
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Functional Assessment of Bioprosthetic Aortic Valves by CMR.
    Maragiannis D; Jackson MS; Flores-Arredondo JH; Autry K; Schutt RC; Alvarez PA; Zoghbi WA; Shah DJ; Little SH
    JACC Cardiovasc Imaging; 2016 Jul; 9(7):785-793. PubMed ID: 27184505
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Results of percutaneous and transapical transcatheter aortic valve implantation performed by a surgical team.
    Bleiziffer S; Ruge H; Mazzitelli D; Schreiber C; Hutter A; Laborde JC; Bauernschmitt R; Lange R
    Eur J Cardiothorac Surg; 2009 Apr; 35(4):615-20; discussion 620-1. PubMed ID: 19233669
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Migration forces of transcatheter aortic valves in patients with noncalcific aortic insufficiency.
    Dwyer HA; Matthews PB; Azadani A; Ge L; Guy TS; Tseng EE
    J Thorac Cardiovasc Surg; 2009 Nov; 138(5):1227-33. PubMed ID: 19748632
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mid-term pattern of survival, hemodynamic performance and rate of complications after medtronic freestyle versus homograft full aortic root replacement: results from a prospective randomized trial.
    Melina G; De Robertis F; Gaer JA; Amrani M; Khaghani A; Yacoub MH
    J Heart Valve Dis; 2004 Nov; 13(6):972-5; discussion 975-6. PubMed ID: 15597592
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study.
    Grube E; Laborde JC; Gerckens U; Felderhoff T; Sauren B; Buellesfeld L; Mueller R; Menichelli M; Schmidt T; Zickmann B; Iversen S; Stone GW
    Circulation; 2006 Oct; 114(15):1616-24. PubMed ID: 17015786
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Could activated tissue remodeling be considered as early marker for progressive valve degeneration? Comparative analysis of checkpoint and ECM remodeling gene expression in native degenerating aortic valves and after bioprosthetic replacement.
    Yeghiazaryan K; Skowasch D; Bauriedel G; Schild H; Golubnitschaja O
    Amino Acids; 2007 Jan; 32(1):109-14. PubMed ID: 16874466
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In-vitro hemodynamics of stented bioprosthetic heart valves in the tilted implantation position.
    Babin-Ebell J; Sievers HH; Misfeld M; Runge M; Vogt PR; Scharfschwerdt M
    J Heart Valve Dis; 2008 Sep; 17(5):566-70. PubMed ID: 18980091
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.