These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

208 related articles for article (PubMed ID: 15315540)

  • 1. Accuracy and clinical usefulness of the near-patient testing CoaguChek S international normalised ratio monitor in rural medical practice.
    Jackson SL; Bereznicki LR; Peterson GM; Marsden KA; Jupe DM; Vial JH; Rasiah RL; Misan G; Williams SM
    Aust J Rural Health; 2004 Aug; 12(4):137-42. PubMed ID: 15315540
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy and clinical usefulness of the CoaguChek S and XS Point of Care devices when starting warfarin in a hospital outreach setting.
    Sobieraj-Teague M; Daniel D; Farrelly B; Coghlan D; Gallus A
    Thromb Res; 2009 Apr; 123(6):909-13. PubMed ID: 19042011
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improving the outcomes of anticoagulation in rural Australia: an evaluation of pharmacist-assisted monitoring of warfarin therapy.
    Jackson SL; Peterson GM; Bereznicki LR; Misan GM; Jupe DM; Vial JH
    J Clin Pharm Ther; 2005 Aug; 30(4):345-53. PubMed ID: 15985048
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of a training program for device operators in the Australian Government's Point of Care Testing in General Practice Trial: issues and implications for rural and remote practices.
    Shephard MD; Mazzachi BC; Watkinson L; Shephard AK; Laurence C; Gialamas A; Bubner T
    Rural Remote Health; 2009; 9(3):1189. PubMed ID: 19689171
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Acceptability of CoaguChek S and CoaguChek XS generated international normalised ratios against a laboratory standard in a paediatric setting.
    Williams VK; Griffiths AB
    Pathology; 2007 Dec; 39(6):575-9. PubMed ID: 18027261
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin.
    Bauman ME; Black KL; Massicotte MP; Bauman ML; Kuhle S; Howlett-Clyne S; Cembrowski GS; Bajzar L
    Thromb Haemost; 2008 Jun; 99(6):1097-103. PubMed ID: 18521514
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring.
    Bereznicki LR; Jackson SL; Peterson GM; Jeffrey EC; Marsden KA; Jupe DM
    J Clin Pathol; 2007 Mar; 60(3):311-4. PubMed ID: 16751303
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95).
    Greenway A; Ignjatovic V; Summerhayes R; Newall F; Burgess J; DeRosa L; Monagle P
    Thromb Haemost; 2009 Jul; 102(1):159-65. PubMed ID: 19572081
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of capillary whole blood international normalized ratio on the CoaguChek S, CoaguChek XS, and i-STAT 1 point-of-care analyzers.
    Karon BS; McBane RD; Chaudhry R; Beyer LK; Santrach PJ
    Am J Clin Pathol; 2008 Jul; 130(1):88-92. PubMed ID: 18550476
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessing agreement between point of care and pathology laboratory results for INR: experiences from the Point of Care Testing in General Practice Trial.
    Yelland LN; Gialamas A; Laurence CO; Willson KJ; Ryan P; Beilby JJ;
    Pathology; 2010 Feb; 42(2):155-9. PubMed ID: 20085517
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of international normalized ratio determined by portable venous-blood coagulation monitor versus a central laboratory.
    Sirithunyanont C; Bhuripanyo K; Kangkagate C; Winyarat W; Srichaya P; Wangtip K
    J Med Assoc Thai; 2003 May; 86 Suppl 1():S67-75. PubMed ID: 12866771
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Point-of-care monitoring of anticoagulant therapy by rural community pharmacists: description of successful outcomes.
    Jackson SL; Peterson GM; House M; Bartlett T
    Aust J Rural Health; 2004 Oct; 12(5):197-200. PubMed ID: 15588262
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of CoaguChek XS for point-of-care antithrombotic monitoring in children with heart disease.
    Moon JR; Jeong SI; Huh J; Lee HJ; Park PW; Kang IS
    Ann Clin Lab Sci; 2010; 40(3):247-51. PubMed ID: 20689136
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative study of accuracy and clinical agreement of the CoaguChek XS portable device versus standard laboratory practice in unexperienced patients.
    Torreiro EG; Fernández EG; Rodríguez RM; López CV; Núñez JB
    Thromb Haemost; 2009 May; 101(5):969-74. PubMed ID: 19404552
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance evaluation of the new CoaguChek XS system compared with the established CoaguChek system by patients experienced in INR-self management.
    Braun S; Watzke H; Hasenkam JM; Schwab M; Wolf T; Dovifat C; Völler H
    Thromb Haemost; 2007 Feb; 97(2):310-4. PubMed ID: 17264962
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analytical performance of the new coagulation monitoring system INRatio for the determination of INR compared with the coagulation monitor Coaguchek S and an established laboratory method.
    Taborski U; Braun SL; Völler H
    J Thromb Thrombolysis; 2004 Oct; 18(2):103-7. PubMed ID: 15789176
    [TBL] [Abstract][Full Text] [Related]  

  • 17. INR comparison between the CoaguChek S and a standard laboratory method among patients with self-management of oral anticoagulation.
    Hentrich DP; Fritschi J; Müller PR; Wuillemin WA
    Thromb Res; 2007; 119(4):489-95. PubMed ID: 16765423
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The reliability of point-of-care prothrombin time testing. A comparison of CoaguChek S and XS INR measurements with hospital laboratory monitoring.
    Ryan F; O'Shea S; Byrne S
    Int J Lab Hematol; 2010 Feb; 32(1 Pt 1):e26-33. PubMed ID: 19032373
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Self-monitoring of oral anticoagulation therapy in children.
    Paioni P; Kroiss S; Kägi E; Bergsträsser E; Fasnacht M; Bauersfeld U; Schmugge M; Albisetti M
    Acta Haematol; 2009; 122(1):58-63. PubMed ID: 19816011
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Results of the performance verification of the CoaguChek XS system.
    Plesch W; Wolf T; Breitenbeck N; Dikkeschei LD; Cervero A; Perez PL; van den Besselaar AM
    Thromb Res; 2008; 123(2):381-9. PubMed ID: 18585761
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.