These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

216 related articles for article (PubMed ID: 15332602)

  • 1. Influence of octacalcium phosphate coating on osteoinductive properties of biomaterials.
    Habibovic P; van der Valk CM; van Blitterswijk CA; De Groot K; Meijer G
    J Mater Sci Mater Med; 2004 Apr; 15(4):373-80. PubMed ID: 15332602
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biological performance of uncoated and octacalcium phosphate-coated Ti6Al4V.
    Habibovic P; Li J; van der Valk CM; Meijer G; Layrolle P; van Blitterswijk CA; de Groot K
    Biomaterials; 2005 Jan; 26(1):23-36. PubMed ID: 15193878
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo comparison of bone formation on titanium implant surfaces coated with biomimetically deposited calcium phosphate or electrochemically deposited hydroxyapatite.
    Yang GL; He FM; Song E; Hu JA; Wang XX; Zhao SF
    Int J Oral Maxillofac Implants; 2010; 25(4):669-80. PubMed ID: 20657861
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bone response adjacent to calcium phosphate electrostatic spray deposition coated implants: an experimental study in goats.
    Manders PJ; Wolke JG; Jansen JA
    Clin Oral Implants Res; 2006 Oct; 17(5):548-53. PubMed ID: 16958695
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomimetic and electrolytic calcium phosphate coatings on titanium alloy: physicochemical characteristics and cell attachment.
    Wang J; Layrolle P; Stigter M; de Groot K
    Biomaterials; 2004 Feb; 25(4):583-92. PubMed ID: 14607496
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vivo implantation of porous titanium alloy implants coated with magnesium-doped octacalcium phosphate and hydroxyapatite thin films using pulsed laser depostion.
    Mróz W; Budner B; Syroka R; Niedzielski K; Golański G; Slósarczyk A; Schwarze D; Douglas TE
    J Biomed Mater Res B Appl Biomater; 2015 Jan; 103(1):151-8. PubMed ID: 24801401
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 3D microenvironment as essential element for osteoinduction by biomaterials.
    Habibovic P; Yuan H; van der Valk CM; Meijer G; van Blitterswijk CA; de Groot K
    Biomaterials; 2005 Jun; 26(17):3565-75. PubMed ID: 15621247
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrolytic deposition of octacalcium phosphate/collagen composite coating on titanium alloy.
    Miao S; Weng W; Li Z; Cheng K; Du P; Shen G; Han G
    J Mater Sci Mater Med; 2009 Jan; 20(1):131-4. PubMed ID: 18704651
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro and in vivo degradation of biomimetic octacalcium phosphate and carbonate apatite coatings on titanium implants.
    Barrère F; van der Valk CM; Dalmeijer RA; van Blitterswijk CA; de Groot K; Layrolle P
    J Biomed Mater Res A; 2003 Feb; 64(2):378-87. PubMed ID: 12522826
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrochemical activation of titanium for biomimetic coating of calcium phosphate.
    Zhang Q; Leng Y
    Biomaterials; 2005 Jun; 26(18):3853-9. PubMed ID: 15626433
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Osteointegration of femoral stem prostheses with a bilayered calcium phosphate coating.
    Goyenvalle E; Aguado E; Nguyen JM; Passuti N; Le Guehennec L; Layrolle P; Daculsi G
    Biomaterials; 2006 Mar; 27(7):1119-28. PubMed ID: 16139882
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hydroxyapatite and collagen combination-coated dental implants display better bone formation in the peri-implant area than the same combination plus bone morphogenetic protein-2-coated implants, hydroxyapatite only coated implants, and uncoated implants.
    Lee SW; Hahn BD; Kang TY; Lee MJ; Choi JY; Kim MK; Kim SG
    J Oral Maxillofac Surg; 2014 Jan; 72(1):53-60. PubMed ID: 24331565
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enhanced biocompatibility and improved osteogenesis of coralline hydroxyapatite modified by bone morphogenetic protein 2 incorporated into a biomimetic coating.
    Lin X; Hunziker EB; Liu T; Hu Q; Liu Y
    Mater Sci Eng C Mater Biol Appl; 2019 Mar; 96():329-336. PubMed ID: 30606540
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of bone ingrowth potential of biomimetic hydroxyapatite and brushite coated porous E-beam structures.
    Biemond JE; Eufrásio TS; Hannink G; Verdonschot N; Buma P
    J Mater Sci Mater Med; 2011 Apr; 22(4):917-25. PubMed ID: 21327405
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A mechanical evaluation of TiO2-gritblasted and Ca-P magnetron sputter coated implants placed into the trabecular bone of the goat: Part 1.
    Vercaigne S; Wolke JG; Naert I; Jansen JA
    Clin Oral Implants Res; 2000 Aug; 11(4):305-13. PubMed ID: 11168223
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dynamics of Renewal of Cell Populations of the Bone Tissue on the Surface of Titanium Implants with Bioactive Coating during Fracture Modeling in Rats.
    Matveeva NY; Kalinichenko SG; Kostiv RE
    Bull Exp Biol Med; 2021 Aug; 171(4):559-565. PubMed ID: 34549337
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Fast formation of biomimetic apatite coatings on pure porous titanium implant's surface].
    He F; Lin L; Zhao S; Zhao S; Chen S; Wang X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Aug; 24(4):806-11. PubMed ID: 17899750
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biological performance of biomimetic calcium phosphate coating of titanium implants in the dog mandible.
    Schliephake H; Scharnweber D; Dard M; Röbetaler S; Sewing A; Hüttmann C
    J Biomed Mater Res A; 2003 Feb; 64(2):225-34. PubMed ID: 12522808
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bone tissue engineering on amorphous carbonated apatite and crystalline octacalcium phosphate-coated titanium discs.
    Dekker RJ; de Bruijn JD; Stigter M; Barrere F; Layrolle P; van Blitterswijk CA
    Biomaterials; 2005 Sep; 26(25):5231-9. PubMed ID: 15792550
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative in vivo study of six hydroxyapatite-based bone graft substitutes.
    Habibovic P; Kruyt MC; Juhl MV; Clyens S; Martinetti R; Dolcini L; Theilgaard N; van Blitterswijk CA
    J Orthop Res; 2008 Oct; 26(10):1363-70. PubMed ID: 18404698
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.