These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 15337964)

  • 21. Rest and exercise hemodynamics following aortic valve replacement. A comparison between 19 and 21 mm Ionescu-Shiley pericardial and Carpentier-Edwards porcine valves.
    Bove EL; Marvasti MA; Potts JL; Reger MJ; Zamora JL; Eich RH; Parker FB
    J Thorac Cardiovasc Surg; 1985 Nov; 90(5):750-5. PubMed ID: 4058047
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical and hemodynamic evaluation of small Perimount aortic valves in patients aged 75 years or older.
    Vitale N; Clark SC; Ramsden A; Hasan A; Hilton CJ; Holden MP
    Ann Thorac Surg; 2003 Jan; 75(1):35-9; discussion 40. PubMed ID: 12537189
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Hemodynamic evaluation of 19-mm Carpentier-Edwards pericardial bioprosthesis in aortic position.
    Takakura H; Sasaki T; Hashimoto K; Hachiya T; Onoguchi K; Oshiumi M; Takeuchi S
    Ann Thorac Surg; 2001 Feb; 71(2):609-13. PubMed ID: 11235715
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Doppler sonographic evaluation of the Duromedics-Edwards bileaflet valve at five-year follow up.
    Globits S; Rödler S; Moritz A; Schreiner W; Pacher R; Glogar D; Wolner E
    J Heart Valve Dis; 1993 Nov; 2(6):665-70. PubMed ID: 7719508
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Mitral prostheses with and without dysfunction: evaluation using 2-D Doppler echocardiography].
    Bernardes L; Abreu J; Soares R; Matos P; Ramos JS; Salomão S
    Rev Port Cardiol; 1990 Dec; 9(12):973-9. PubMed ID: 2093337
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Doppler haemodynamic profiles of clinically and echocardiographically normal mitral and aortic valve prostheses.
    Nihoyannopoulos P; Kambouroglou D; Athanassopoulos G; Nadazdin A; Smith P; Oakley CM
    Eur Heart J; 1992 Mar; 13(3):348-55. PubMed ID: 1597221
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Carpentier-Edwards Perimount Magna valve versus Medtronic Hancock II: a matched hemodynamic comparison.
    Borger MA; Nette AF; Maganti M; Feindel CM
    Ann Thorac Surg; 2007 Jun; 83(6):2054-8. PubMed ID: 17532395
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Doppler echocardiographic assessment of normally functioning Starr-Edwards, carbomedics and Carpentier-Edwards valves in aortic position.
    Chakraborty B; Quek S; Pin DZ; Siong CT; Kheng TL
    Angiology; 1996 May; 47(5):481-9. PubMed ID: 8644945
    [TBL] [Abstract][Full Text] [Related]  

  • 29. In vivo hemodynamic comparison of porcine and pericardial valves.
    Cosgrove DM; Lytle BW; Gill CC; Golding LA; Stewart RW; Loop FD; Williams GW
    J Thorac Cardiovasc Surg; 1985 Mar; 89(3):358-68. PubMed ID: 3974271
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Very late outcomes for mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 25-year follow-up of 450 implantations.
    Bourguignon T; Bouquiaux-Stablo AL; Loardi C; Mirza A; Candolfi P; Marchand M; Aupart MR
    J Thorac Cardiovasc Surg; 2014 Nov; 148(5):2004-2011.e1. PubMed ID: 24667021
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Hemodynamic comparison of Hancock and Carpentier-Edwards mitral bioprosthetic valves.
    Khan S; Mitchell RS; Derby GC; Oyer PE; Miller DC
    Circulation; 1990 Nov; 82(5 Suppl):IV75-81. PubMed ID: 2225438
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Hemodynamic performance of small aortic valve bioprostheses: is there a difference?
    McDonald ML; Daly RC; Schaff HV; Mullany CJ; Miller FA; Morris JJ; Orszulak TA
    Ann Thorac Surg; 1997 Feb; 63(2):362-6. PubMed ID: 9033301
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The effective orifice area/patient aortic annulus area ratio: a better way to compare different bioprostheses? A prospective randomized comparison of the Mosaic and Perimount bioprostheses in the aortic position.
    Eichinger WB; Botzenhardt F; Guenzinger R; Bleiziffer S; Keithahn A; Bauernschmitt R; Lange R
    J Heart Valve Dis; 2004 May; 13(3):382-8; discussion 388-9. PubMed ID: 15222284
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Long-term echocardiographic follow-up of patients with a tricuspid bioprosthesis.
    Okada Y; Nasu M; Nishiuchi S; Shomura T
    ASAIO Trans; 1990; 36(3):M535-7. PubMed ID: 2252744
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Two years' clinical experience with a quadrileaflet stentless bioprosthesis in the mitral position.
    Aybek T; Simon A; Dogan S; Greinecker GW; Moritz A
    J Heart Valve Dis; 2000 Sep; 9(5):667-73. PubMed ID: 11041182
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [A Doppler echocardiographic study of normal and dysfunctioning Carpentier-Edwards bioprostheses].
    Bonaduce D; Breglio R; Conforti G; Montemurro MV; Petretta M; Covino E; Morgano G; Bianchi V
    G Ital Cardiol; 1990 Jan; 20(1):50-7. PubMed ID: 2328859
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Doppler echocardiographic evaluation of the Bioflo pericardial bioprosthesis.
    Gonzalez-Juanatey JR; Garcia-Bengoechea JB; Vega M; Garcia-Acuna JM; Rubio J; Duran D; Sierra J; Gil M
    J Heart Valve Dis; 1993 May; 2(3):315-9; discussion 320. PubMed ID: 8269126
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Structural valve deterioration in mitral replacement surgery: comparison of Carpentier-Edwards supra-annular porcine and perimount pericardial bioprostheses.
    Eric Jamieson WR; Marchand MA; Pelletier CL; Norton R; Pellerin M; Dubiel TW; Aupart MR; Daenen WJ; Holden MP; David TE; Ryba EA; Anderson WN
    J Thorac Cardiovasc Surg; 1999 Aug; 118(2):297-304. PubMed ID: 10425003
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Doppler echocardiographic assessment of TTK Chitra prosthetic heart valve in the mitral position.
    Namboodiri N; Shajeem O; Tharakan JA; Sankarkumar R; Titus T; Valaparambil A; Sivasankaran S; Krishnamoorthy KM; Harikrishnan SP; Dora SK
    Eur J Echocardiogr; 2008 Sep; 9(5):599-604. PubMed ID: 18296411
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of normal hemodynamic profile of CarboMedics prosthetic valves by Doppler echocardiography.
    Chakraborty B; Quek S; Pin DZ; Siong CT; Kheng TL
    Angiology; 1997 Dec; 48(12):1055-61. PubMed ID: 9404832
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.