These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

391 related articles for article (PubMed ID: 15342282)

  • 1. Accuracy of measurement of left ventricular volume and ejection fraction by new real-time three-dimensional echocardiography in patients with wall motion abnormalities secondary to myocardial infarction.
    Arai K; Hozumi T; Matsumura Y; Sugioka K; Takemoto Y; Yamagishi H; Yoshiyama M; Kasanuki H; Yoshikawa J
    Am J Cardiol; 2004 Sep; 94(5):552-8. PubMed ID: 15342282
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction.
    Jenkins C; Bricknell K; Chan J; Hanekom L; Marwick TH
    Am J Cardiol; 2007 Feb; 99(3):300-6. PubMed ID: 17261386
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography.
    Nishikage T; Nakai H; Mor-Avi V; Lang RM; Salgo IS; Settlemier SH; Husson S; Takeuchi M
    Eur J Echocardiogr; 2009 Jan; 10(1):82-8. PubMed ID: 18490270
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of automated measurement of left ventricular volume by novel real-time 3-dimensional echocardiographic system: Validation with cardiac magnetic resonance imaging and 2-dimensional echocardiography.
    Shibayama K; Watanabe H; Iguchi N; Sasaki S; Mahara K; Umemura J; Sumiyoshi T
    J Cardiol; 2013 Apr; 61(4):281-8. PubMed ID: 23466066
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Real-time 3-dimensional echocardiography early after acute myocardial infarction: incremental value of echo-contrast for assessment of left ventricular function.
    Nucifora G; Marsan NA; Holman ER; Siebelink HM; van Werkhoven JM; Scholte AJ; van der Wall EE; Schalij MJ; Bax JJ
    Am Heart J; 2009 May; 157(5):882.e1-8. PubMed ID: 19376315
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function.
    Cosyns B; Haberman D; Droogmans S; Warzée S; Mahieu P; Laurent E; Moonen M; Hernot S; Lancellotti P
    Cardiovasc Ultrasound; 2009 Jun; 7():27. PubMed ID: 19531259
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative Assessment of Right Ventricular Volumes and Ejection Fraction in Patients with Left Ventricular Systolic Dysfunction by Real Time Three-Dimensional Echocardiography versus Cardiac Magnetic Resonance Imaging.
    Kim J; Cohen SB; Atalay MK; Maslow AD; Poppas A
    Echocardiography; 2015 May; 32(5):805-12. PubMed ID: 25109323
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional echocardiography in various types of heart disease: a comparison study of magnetic resonance imaging and 64-slice computed tomography in a real-world population.
    Squeri A; Censi S; Reverberi C; Gaibazzi N; Baldelli M; Binno SM; Properzi E; Bosi S
    J Echocardiogr; 2017 Mar; 15(1):18-26. PubMed ID: 27589871
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy and reproducibility of quantitation of left ventricular function by real-time three-dimensional echocardiography versus cardiac magnetic resonance.
    Soliman OI; Kirschbaum SW; van Dalen BM; van der Zwaan HB; Mahdavian Delavary B; Vletter WB; van Geuns RJ; Ten Cate FJ; Geleijnse ML
    Am J Cardiol; 2008 Sep; 102(6):778-83. PubMed ID: 18774006
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of contrast agent-enhanced versus non-contrast agent-enhanced real-time three-dimensional echocardiography for analysis of left ventricular systolic function.
    Krenning BJ; Kirschbaum SW; Soliman OI; Nemes A; van Geuns RJ; Vletter WB; Veltman CE; Ten Cate FJ; Roelandt JR; Geleijnse ML
    Am J Cardiol; 2007 Nov; 100(9):1485-9. PubMed ID: 17950813
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reproducibility of right ventricular volumes and ejection fraction using real-time three-dimensional echocardiography: comparison with cardiac MRI.
    Jenkins C; Chan J; Bricknell K; Strudwick M; Marwick TH
    Chest; 2007 Jun; 131(6):1844-51. PubMed ID: 17400663
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Value of real time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy: comparison with two-dimensional echocardiography and magnetic resonance imaging.
    Bicudo LS; Tsutsui JM; Shiozaki A; Rochitte CE; Arteaga E; Mady C; Ramires JA; Mathias W
    Echocardiography; 2008 Aug; 25(7):717-26. PubMed ID: 18445062
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Non-invasive assessment of myocardial ischaemia using new real-time three-dimensional dobutamine stress echocardiography: comparison with conventional two-dimensional methods.
    Matsumura Y; Hozumi T; Arai K; Sugioka K; Ujino K; Takemoto Y; Yamagishi H; Yoshiyama M; Yoshikawa J
    Eur Heart J; 2005 Aug; 26(16):1625-32. PubMed ID: 15817607
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance.
    Macron L; Lim P; Bensaid A; Nahum J; Dussault C; Mitchell-Heggs L; Dubois-Randé JL; Deux JF; Gueret P
    Circ Cardiovasc Imaging; 2010 Jul; 3(4):450-5. PubMed ID: 20435854
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Three-dimensional echocardiography for the preoperative assessment of patients with left ventricular aneurysm.
    Marsan NA; Westenberg JJ; Roes SD; van Bommel RJ; Delgado V; van der Geest RJ; de Roos A; Klautz RJ; Reiber JC; Bax JJ
    Ann Thorac Surg; 2011 Jan; 91(1):113-21. PubMed ID: 21172497
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Feasibility of single-beat full-volume capture real-time three-dimensional echocardiography and auto-contouring algorithm for quantification of left ventricular volume: validation with cardiac magnetic resonance imaging.
    Chang SA; Lee SC; Kim EY; Hahm SH; Jang SY; Park SJ; Choi JO; Park SW; Choe YH; Oh JK
    J Am Soc Echocardiogr; 2011 Aug; 24(8):853-9. PubMed ID: 21645992
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Right ventricular ejection fraction and left ventricular dyssynchrony by 3D echo correlate with functional impairment in patients with dilated cardiomyopathy.
    D'Andrea A; Gravino R; Riegler L; Salerno G; Scarafile R; Romano M; Cuomo S; Del Viscovo L; Ferrara I; De Rimini ML; Muto P; Limongelli G; Pacileo G; Bossone E; Russo MG; Calabrò R
    J Card Fail; 2011 Apr; 17(4):309-17. PubMed ID: 21440869
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Freehand three-dimensional echocardiography with rotational scanning for measurements of left ventricular volume and ejection fraction in patients with coronary artery disease.
    Fukuda S; Hozumi T; Watanabe H; Muro T; Yamagishi H; Yoshiyama M; Takeuchi K; Yoshikawa J
    Echocardiography; 2005 Feb; 22(2):111-9. PubMed ID: 15693776
    [TBL] [Abstract][Full Text] [Related]  

  • 19. What is the optimal clinical technique for measurement of left ventricular volume after myocardial infarction? A comparative study of 3-dimensional echocardiography, single photon emission computed tomography, and cardiac magnetic resonance imaging.
    Chan J; Jenkins C; Khafagi F; Du L; Marwick TH
    J Am Soc Echocardiogr; 2006 Feb; 19(2):192-201. PubMed ID: 16455424
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters.
    Jenkins C; Chan J; Hanekom L; Marwick TH
    J Am Soc Echocardiogr; 2006 Sep; 19(9):1119-28. PubMed ID: 16950466
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.