These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 15347694)

  • 21. Evaluation of myocardial ischemia using a rest metabolism/stress perfusion protocol with fluorine-18 deoxyglucose/technetium-99m MIBI and dual-isotope simultaneous-acquisition single-photon emission computed tomography.
    Sandler MP; Videlefsky S; Delbeke D; Patton JA; Meyerowitz C; Martin WH; Ohana I
    J Am Coll Cardiol; 1995 Oct; 26(4):870-8. PubMed ID: 7560611
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Correlation of 99mTc-sestamibi SPECT myocardial perfusion imaging with absolute coronary flow reserve by a new noninvasive Doppler method in patients with stenoses of the left anterior descending coronary artery. A preliminary report.
    Caiati C; Cioglia G; Montaldo C; Zedda N; Rubini G; Pirisi R; Iliceto S
    Cardiologia; 1999 Sep; 44(9):809-16. PubMed ID: 10609390
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Gated (99m)Tc-tetrofosmin SPECT for discriminating infarct from artifact in fixed myocardial perfusion defects.
    Fleischmann S; Koepfli P; Namdar M; Wyss CA; Jenni R; Kaufmann PA
    J Nucl Med; 2004 May; 45(5):754-9. PubMed ID: 15136622
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of probable or possible dementia with lewy bodies using 123I-IMP brain perfusion SPECT, 123I-MIBG, and 99mTc-MIBI myocardial SPECT.
    Inui Y; Toyama H; Manabe Y; Sato T; Sarai M; Kosaka K; Iwata N; Katada K
    J Nucl Med; 2007 Oct; 48(10):1641-50. PubMed ID: 17873141
    [TBL] [Abstract][Full Text] [Related]  

  • 25. SPECT versus planar 99mTc-sestamibi myocardial scintigraphy: comparison of accuracy and impact on patient management in chronic ischemic heart disease.
    Cramer MJ; van der Wall EE; Verzijlbergen JF; Jaarsma W; Niemeyer MG; Zwindrman AH; Ascoop CA; Pauwels EK
    Q J Nucl Med; 1997 Mar; 41(1):1-9. PubMed ID: 9195847
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Feasibility of simultaneous stress 99mTc-sestamibi/rest 201Tl dual-isotope myocardial perfusion SPECT in the detection of coronary artery disease.
    Nakamura M; Takeda K; Ichihara T; Motomura N; Shimizu H; Saito Y; Nomura Y; Isaka N; Konishi T; Nakano T
    J Nucl Med; 1999 Jun; 40(6):895-903. PubMed ID: 10452303
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration.
    Goetze S; Brown TL; Lavely WC; Zhang Z; Bengel FM
    J Nucl Med; 2007 Jul; 48(7):1090-5. PubMed ID: 17574985
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Myocardial perfusion SPECT horizontal motion artifact.
    Agarwal V; DePuey EG
    J Nucl Cardiol; 2014 Dec; 21(6):1260-5. PubMed ID: 24980456
    [No Abstract]   [Full Text] [Related]  

  • 29. Left ventricular wall motion abnormalities as well as reduced wall thickness can cause false positive results of routine SPECT perfusion imaging for detection of myocardial infarction.
    Mahrholdt H; Zhydkov A; Hager S; Meinhardt G; Vogelsberg H; Wagner A; Sechtem U
    Eur Heart J; 2005 Oct; 26(20):2127-35. PubMed ID: 16006444
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Added value of rest to stress study for recognition of artifacts in perfusion cardiovascular magnetic resonance.
    Thomson LE; Fieno DS; Abidov A; Slomka PJ; Hachamovitch R; Saouaf R; Friedman JD; Berman DS
    J Cardiovasc Magn Reson; 2007; 9(5):733-40. PubMed ID: 17891609
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Evaluation of hemodynamic significance of arteriovenous coronary fistulas: diagnostic integration of coronary angiography and stress/rest myocardial scintigraphy].
    Rubini G; Ettorre GC; Sebastiani M; Bovenzi F
    Radiol Med; 2000 Dec; 100(6):453-8. PubMed ID: 11307506
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Gated spect myocardial perfusion scintigraphy for identifying septal perfusion artifacts in left bundle branch block.
    Afzal MS; Imran MB; Aslam N; Khurshid SJ; Khan MA; Irfan J; Farooq UI; Shoaib M; Akhtar MS; Muhammad K; Nadeem A
    J Coll Physicians Surg Pak; 2006 Aug; 16(8):504-8. PubMed ID: 16899176
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [New trials for improving diagnostic accuracy of stress technetium-99m-tetrofosmin single photon emission computed tomography].
    Sasaki R; Mitani I; Kitamura Y; Nemoto T; Tsukahara K; Tanaka Y; Higuma K
    J Cardiol; 2002 Jan; 39(1):11-7. PubMed ID: 11828793
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Prognostic value of automated quantification of 99mTc-sestamibi myocardial perfusion imaging.
    Leslie WD; Tully SA; Yogendran MS; Ward LM; Nour KA; Metge CJ
    J Nucl Med; 2005 Feb; 46(2):204-11. PubMed ID: 15695777
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A new algorithm for the quantitation of myocardial perfusion SPECT. II: validation and diagnostic yield.
    Sharir T; Germano G; Waechter PB; Kavanagh PB; Areeda JS; Gerlach J; Kang X; Lewin HC; Berman DS
    J Nucl Med; 2000 Apr; 41(4):720-7. PubMed ID: 10768575
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optimisation of reconstruction--reprojection-based motion correction for cardiac SPECT.
    Kangasmaa TS; Sohlberg AO
    Ann Nucl Med; 2014 Jul; 28(6):580-5. PubMed ID: 24599825
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Real-time perfusion adenosine stress echocardiography versus myocardial perfusion adenosine scintigraphy for the detection of myocardial ischaemia in patients with stable coronary artery disease.
    Gudmundsson P; Winter R; Dencker M; Kitlinski M; Thorsson O; Ljunggren L; Willenheimer R
    Clin Physiol Funct Imaging; 2006 Jan; 26(1):32-8. PubMed ID: 16398668
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Gated single-photon emission computed tomography. The present-day ''one-stop-shop'' for cardiac imaging.
    Sciagrà R; Leoncini M
    Q J Nucl Med Mol Imaging; 2005 Mar; 49(1):19-29. PubMed ID: 15724133
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Myocardial scintigraphy by the gated SPECT method in coronary disease patients with postischemic stunning].
    Bestetti A; Triulzi A; Di Leo C; Tagliabue L; Del Sole A; Lomuscio A; Vergani D; Tarricone D; Marano L; Fiorentini C; Tarolo GL
    G Ital Cardiol; 1999 Feb; 29(2):143-8. PubMed ID: 10088069
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of stress perfusion MRI and SPECT for detection of myocardial ischemia in patients with angiographically proven three-vessel coronary artery disease.
    Chung SY; Lee KY; Chun EJ; Lee WW; Park EK; Chang HJ; Choi SI
    AJR Am J Roentgenol; 2010 Aug; 195(2):356-62. PubMed ID: 20651190
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.