142 related articles for article (PubMed ID: 15348177)
1. Enhanced wear performance of ultra high molecular weight polyethylene crosslinked by organosilane.
Tang CY; Xie XL; Wu XC; Li RK; Mai YW
J Mater Sci Mater Med; 2002 Nov; 13(11):1065-9. PubMed ID: 15348177
[TBL] [Abstract][Full Text] [Related]
2. Wear performance of ultrahigh molecular weight polyethylene/quartz composites.
Xie XL; Tang CY; Chan KY; Wu XC; Tsui CP; Cheung CY
Biomaterials; 2003 May; 24(11):1889-96. PubMed ID: 12615479
[TBL] [Abstract][Full Text] [Related]
3. Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE).
Muratoglu OK; Bragdon CR; O'Connor DO; Jasty M; Harris WH; Gul R; McGarry F
Biomaterials; 1999 Aug; 20(16):1463-70. PubMed ID: 10458559
[TBL] [Abstract][Full Text] [Related]
4. Influence of heat treatment on structural, mechanical and wear properties of crosslinked UHMWPE.
Chiesa R; Moscatelli M; Giordano C; Siccardi F; Cigada A
J Appl Biomater Biomech; 2004; 2(1):20-8. PubMed ID: 20803447
[TBL] [Abstract][Full Text] [Related]
5. Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior.
Sobieraj MC; Rimnac CM
J Mech Behav Biomed Mater; 2009 Oct; 2(5):433-43. PubMed ID: 19627849
[TBL] [Abstract][Full Text] [Related]
6. Natural polyphenol-stabilised highly crosslinked UHMWPE with high mechanical properties and low wear for joint implants.
Fu J; Shen J; Gao G; Xu Y; Hou R; Cong Y; Cheng Y
J Mater Chem B; 2013 Oct; 1(37):4727-4735. PubMed ID: 32261156
[TBL] [Abstract][Full Text] [Related]
7. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.
Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH
Biomed Mater Eng; 2001; 11(1):23-35. PubMed ID: 11281576
[TBL] [Abstract][Full Text] [Related]
8. Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements.
Kurtz SM; Villarraga ML; Herr MP; Bergström JS; Rimnac CM; Edidin AA
Biomaterials; 2002 Sep; 23(17):3681-97. PubMed ID: 12109694
[TBL] [Abstract][Full Text] [Related]
9. Enhanced wear performance of highly crosslinked UHMWPE for artificial joints.
Chiesa R; Tanzi MC; Alfonsi S; Paracchini L; Moscatelli M; Cigada A
J Biomed Mater Res; 2000 Jun; 50(3):381-7. PubMed ID: 10737880
[TBL] [Abstract][Full Text] [Related]
10. Simulation of Neutron/Self-Emitted Gamma Attenuation and Effects of Silane Surface Treatment on Mechanical and Wear Resistance Properties of Sm
Toyen D; Paopun Y; Changjan D; Wimolmala E; Mahathanabodee S; Pianpanit T; Anekratmontree T; Saenboonruang K
Polymers (Basel); 2021 Oct; 13(19):. PubMed ID: 34641205
[TBL] [Abstract][Full Text] [Related]
11. Wear of crosslinked polyethylene under different tribological conditions.
Galvin A; Kang L; Tipper J; Stone M; Ingham E; Jin Z; Fisher J
J Mater Sci Mater Med; 2006 Mar; 17(3):235-43. PubMed ID: 16555115
[TBL] [Abstract][Full Text] [Related]
12. The influence of irradiation dose on mechanical properties and wear resistance of molded and extruded ultra high molecular weight polyethylene.
Xiong L; Xiong D
J Mech Behav Biomed Mater; 2012 May; 9():73-82. PubMed ID: 22498285
[TBL] [Abstract][Full Text] [Related]
13. Friction and wear behavior of ultra-high molecular weight polyethylene as a function of polymer crystallinity.
Kanaga Karuppiah KS; Bruck AL; Sundararajan S; Wang J; Lin Z; Xu ZH; Li X
Acta Biomater; 2008 Sep; 4(5):1401-10. PubMed ID: 18378200
[TBL] [Abstract][Full Text] [Related]
14. The relative effects of radiation crosslinking and type of counterface on the wear resistance of ultrahigh-molecular-weight polyethylene.
Bistolfi A; Bellare A
Acta Biomater; 2011 Sep; 7(9):3398-403. PubMed ID: 21640855
[TBL] [Abstract][Full Text] [Related]
15. Wear of contemporary total knee replacements--a knee simulator study of six current designs.
Utzschneider S; Harrasser N; Schroeder C; Mazoochian F; Jansson V
Clin Biomech (Bristol, Avon); 2009 Aug; 24(7):583-8. PubMed ID: 19450910
[TBL] [Abstract][Full Text] [Related]
16. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions.
Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A
Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821
[TBL] [Abstract][Full Text] [Related]
17. Comparison of the in vivo wear rates of 43 surgically retrieved direct compression molded and ram extruded ultra high molecular weight polyethylene acetabular components.
Rentfrow ED; James SP; Beauregard GP; Lee KR; McLaughlin JR
Biomed Sci Instrum; 1996; 32():135-41. PubMed ID: 8672661
[TBL] [Abstract][Full Text] [Related]
18. Wear products of total hip arthroplasty: The case of polyethylene.
Massin P; Achour S
Morphologie; 2017 Mar; 101(332):1-8. PubMed ID: 27426252
[TBL] [Abstract][Full Text] [Related]
19. Mechanical properties and biocompatibility of melt processed, self-reinforced ultrahigh molecular weight polyethylene.
Huang YF; Xu JZ; Li JS; He BX; Xu L; Li ZM
Biomaterials; 2014 Aug; 35(25):6687-97. PubMed ID: 24835044
[TBL] [Abstract][Full Text] [Related]
20. Improved wear performance with crosslinked UHMWPE and zirconia implants in knee simulation.
Tsukamoto R; Chen S; Asano T; Ogino M; Shoji H; Nakamura T; Clarke IC
Acta Orthop; 2006 Jun; 77(3):505-11. PubMed ID: 16819693
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]