These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. [Comparison of the Quality of the Most Frequently Used New UHMWPE Articulation Inserts of the Total Hip Replacement]. Fulín P; Šlouf M; Vlková H; Krejčíková S; Kredatusová J; Pokorný D Acta Chir Orthop Traumatol Cech; 2019; 86(2):101-109. PubMed ID: 31070568 [TBL] [Abstract][Full Text] [Related]
24. Ultra-High Molecular Weight Polyethylene: Influence of the Chemical, Physical and Mechanical Properties on the Wear Behavior. A Review. Bracco P; Bellare A; Bistolfi A; Affatato S Materials (Basel); 2017 Jul; 10(7):. PubMed ID: 28773153 [TBL] [Abstract][Full Text] [Related]
25. Study on Preparation of Ultra-High-Molecular-Weight Polyethylene Pipe of Good Thermal-Mechanical Properties Modified with Organo-Montmorillonite by Screw Extrusion. Guo Z; Xu R; Xue P Materials (Basel); 2020 Jul; 13(15):. PubMed ID: 32727121 [TBL] [Abstract][Full Text] [Related]
26. Experimental and numerical modeling of variable friction between nanoregions in coventional and crosslinked UHMWPE. Ho SP; Joseph PF; Drews MJ; Boland T; LaBerge M J Biomech Eng; 2004 Feb; 126(1):111-9. PubMed ID: 15171137 [TBL] [Abstract][Full Text] [Related]
27. The effect of molecular orientation and acetylene-enhanced crosslinking on the wear of UHMWPE in total artificial joints. Marrs H; Barton DC; Doyle C; Jones RA; Lewis EL; Ward IM; Fisher J J Mater Sci Mater Med; 2001 Jul; 12(7):621-8. PubMed ID: 15348255 [TBL] [Abstract][Full Text] [Related]
28. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Endo M; Tipper JL; Barton DC; Stone MH; Ingham E; Fisher J Proc Inst Mech Eng H; 2002; 216(2):111-22. PubMed ID: 12022418 [TBL] [Abstract][Full Text] [Related]
29. Quasi-static and dynamic nanoindentation studies on highly crosslinked ultra-high-molecular-weight polyethylene. Park K; Mishra S; Lewis G; Losby J; Fan Z; Park JB Biomaterials; 2004 May; 25(12):2427-36. PubMed ID: 14741608 [TBL] [Abstract][Full Text] [Related]
30. Long-term wear failure analysis of uhmwpe acetabular cup in total hip replacement. Shahemi N; Liza S; Abbas AA; Merican AM J Mech Behav Biomed Mater; 2018 Nov; 87():1-9. PubMed ID: 30031358 [TBL] [Abstract][Full Text] [Related]
31. Properties of crosslinked ultra-high-molecular-weight polyethylene. Lewis G Biomaterials; 2001 Feb; 22(4):371-401. PubMed ID: 11205441 [TBL] [Abstract][Full Text] [Related]
32. Effects of Vitamin E-Stabilized Ultra High Molecular Weight Polyethylene on Oxidative Stress Response and Osteoimmunological Response in Human Osteoblast. Massaccesi L; Ragone V; Papini N; Goi G; Corsi Romanelli MM; Galliera E Front Endocrinol (Lausanne); 2019; 10():203. PubMed ID: 31001202 [TBL] [Abstract][Full Text] [Related]
33. Comparison of the properties of annealed crosslinked (Crossfire) and conventional polyethylene as hip bearing materials. Kurtz SM; Manley M; Wang A; Taylor S; Dumbleton J Bull Hosp Jt Dis; 2002-2003; 61(1-2):17-26. PubMed ID: 12828375 [TBL] [Abstract][Full Text] [Related]
34. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. McKellop H; Shen FW; Lu B; Campbell P; Salovey R J Orthop Res; 1999 Mar; 17(2):157-67. PubMed ID: 10221831 [TBL] [Abstract][Full Text] [Related]
36. Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics. Benson LC; DesJardins JD; LaBerge M J Biomed Mater Res; 2001; 58(5):496-504. PubMed ID: 11505423 [TBL] [Abstract][Full Text] [Related]
40. [Crosslinking modification of ultra high molecular weight polyethylene during joint arthroplasty]. Tong G; Tian H; Wang C; Wang G Zhonghua Yi Xue Za Zhi; 2015 Jun; 95(21):1695-7. PubMed ID: 26675802 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]