BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

690 related articles for article (PubMed ID: 15351361)

  • 21. Accuracy of EEG source imaging of epileptic spikes in patients with large brain lesions.
    Brodbeck V; Lascano AM; Spinelli L; Seeck M; Michel CM
    Clin Neurophysiol; 2009 Apr; 120(4):679-85. PubMed ID: 19264547
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Multimodal integration of EEG, MEG and fMRI data for the solution of the neuroimage puzzle.
    Babiloni F; Mattia D; Babiloni C; Astolfi L; Salinari S; Basilisco A; Rossini PM; Marciani MG; Cincotti F
    Magn Reson Imaging; 2004 Dec; 22(10):1471-6. PubMed ID: 15707796
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fundamentals of electroencefalography, magnetoencefalography, and functional magnetic resonance imaging.
    Babiloni C; Pizzella V; Gratta CD; Ferretti A; Romani GL
    Int Rev Neurobiol; 2009; 86():67-80. PubMed ID: 19607991
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Source localization of scalp-EEG interictal spikes in posterior cortex epilepsies investigated by HR-EEG and SEEG.
    Gavaret M; Trébuchon A; Bartolomei F; Marquis P; McGonigal A; Wendling F; Regis J; Badier JM; Chauvel P
    Epilepsia; 2009 Feb; 50(2):276-89. PubMed ID: 18717708
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Brain source localization: a new method based on MUltiple SIgnal Classification algorithm and spatial sparsity of the field signal for electroencephalogram measurements.
    Vergallo P; Lay-Ekuakille A
    Rev Sci Instrum; 2013 Aug; 84(8):085117. PubMed ID: 24007117
    [TBL] [Abstract][Full Text] [Related]  

  • 26. EEG source imaging in pediatric epilepsy surgery: a new perspective in presurgical workup.
    Sperli F; Spinelli L; Seeck M; Kurian M; Michel CM; Lantz G
    Epilepsia; 2006 Jun; 47(6):981-90. PubMed ID: 16822244
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Estimation of the cortical functional connectivity with the multimodal integration of high-resolution EEG and fMRI data by directed transfer function.
    Babiloni F; Cincotti F; Babiloni C; Carducci F; Mattia D; Astolfi L; Basilisco A; Rossini PM; Ding L; Ni Y; Cheng J; Christine K; Sweeney J; He B
    Neuroimage; 2005 Jan; 24(1):118-31. PubMed ID: 15588603
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Recording event-related activity under hostile magnetic resonance environment: Is multimodal EEG/ERP-MRI recording possible?
    Karakaş HM; Karakaş S; Ozkan Ceylan A; Tali ET
    Int J Psychophysiol; 2009 Aug; 73(2):123-32. PubMed ID: 19414046
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Removing muscle and eye artifacts using blind source separation techniques in ictal EEG source imaging.
    Hallez H; De Vos M; Vanrumste B; Van Hese P; Assecondi S; Van Laere K; Dupont P; Van Paesschen W; Van Huffel S; Lemahieu I
    Clin Neurophysiol; 2009 Jul; 120(7):1262-72. PubMed ID: 19539525
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Source localization of temporal lobe epilepsy using PCA-LORETA analysis on ictal EEG recordings.
    Stern Y; Neufeld MY; Kipervasser S; Zilberstein A; Fried I; Teicher M; Adi-Japha E
    J Clin Neurophysiol; 2009 Apr; 26(2):109-16. PubMed ID: 19279504
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Magnetoencephalography is more successful for screening and localizing frontal lobe epilepsy than electroencephalography.
    Ossenblok P; de Munck JC; Colon A; Drolsbach W; Boon P
    Epilepsia; 2007 Nov; 48(11):2139-49. PubMed ID: 17662061
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Mapping human brain function with MEG and EEG: methods and validation.
    Darvas F; Pantazis D; Kucukaltun-Yildirim E; Leahy RM
    Neuroimage; 2004; 23 Suppl 1():S289-99. PubMed ID: 15501098
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Gaussian source model based iterative algorithm for EEG source imaging.
    Lei X; Xu P; Chen A; Yao D
    Comput Biol Med; 2009 Nov; 39(11):978-88. PubMed ID: 19691957
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Localization of distributed sources and comparison with functional MRI.
    Lantz G; Spinelli L; Menendez RG; Seeck M; Michel CM
    Epileptic Disord; 2001 Jul; Spec Issue():45-58. PubMed ID: 11781200
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Accuracy of two dipolar inverse algorithms applying reciprocity for forward calculation.
    Laarne P; Hyttinen J; Dodel S; Malmivuo J; Eskola H
    Comput Biomed Res; 2000 Jun; 33(3):172-85. PubMed ID: 10860584
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Lp norm iterative sparse solution for EEG source Localization.
    Xu P; Tian Y; Chen H; Yao D
    IEEE Trans Biomed Eng; 2007 Mar; 54(3):400-9. PubMed ID: 17355051
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Combined distributed source and single-trial EEG-fMRI modeling: application to effortful decision making processes.
    Esposito F; Mulert C; Goebel R
    Neuroimage; 2009 Aug; 47(1):112-21. PubMed ID: 19361566
    [TBL] [Abstract][Full Text] [Related]  

  • 38. 3D source localization derived from subdural strip and grid electrodes: a simulation study.
    Dümpelmann M; Fell J; Wellmer J; Urbach H; Elger CE
    Clin Neurophysiol; 2009 Jun; 120(6):1061-9. PubMed ID: 19394893
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The neuronal sources of EEG: modeling of simultaneous scalp and intracerebral recordings in epilepsy.
    Cosandier-Rimélé D; Merlet I; Badier JM; Chauvel P; Wendling F
    Neuroimage; 2008 Aug; 42(1):135-46. PubMed ID: 18515148
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Localizing epileptogenic regions in partial epilepsy using three-dimensional statistical parametric maps of background EEG source spectra.
    Alper K; Raghavan M; Isenhart R; Howard B; Doyle W; John R; Prichep L
    Neuroimage; 2008 Feb; 39(3):1257-65. PubMed ID: 18024085
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 35.