These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 15361011)

  • 1. EVEREST: an efficient method for verification of digital signatures in real-time teleradiology.
    Bicakci K; Baykal N
    Stud Health Technol Inform; 2004; 107(Pt 2):1241-5. PubMed ID: 15361011
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Authenticity and integrity of digital mammography images.
    Zhou XQ; Huang HK; Lou SL
    IEEE Trans Med Imaging; 2001 Aug; 20(8):784-91. PubMed ID: 11513029
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [A solution to add digital signatures to medical images according to the DICOM standard: embedded systems].
    Schütze B; Kroll M; Filler TJ
    Rofo; 2005 Jan; 177(1):124-9. PubMed ID: 15657831
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Does the digital signature of the DICOM standard meet the requirements of German law?].
    Schütze B; Kroll M; Geisbe T; Braun M; Filler TJ
    Radiologe; 2003 Aug; 43(8):665-70. PubMed ID: 14504768
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Proposal for DICOM multiframe medical image integrity and authenticity.
    Kobayashi LO; Furuie SS
    J Digit Imaging; 2009 Mar; 22(1):71-83. PubMed ID: 18266035
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A region-based lossless watermarking scheme for enhancing security of medical data.
    Guo X; Zhuang TG
    J Digit Imaging; 2009 Mar; 22(1):53-64. PubMed ID: 17619929
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The experimental study on teleradiology system using HDTV and ISDN].
    Kudo T
    Hokkaido Igaku Zasshi; 1995 Nov; 70(6):807-16. PubMed ID: 8582704
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cryptographic framework for document-objects resulting from multiparty collaborative transactions.
    Goh A
    Stud Health Technol Inform; 2000; 77():1069-73. PubMed ID: 11187485
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Providing integrity and authenticity in DICOM images: a novel approach.
    Kobayashi LO; Furuie SS; Barreto PS
    IEEE Trans Inf Technol Biomed; 2009 Jul; 13(4):582-9. PubMed ID: 19244022
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Crypto-Watermarking of Transmitted Medical Images.
    Al-Haj A; Mohammad A; Amer A
    J Digit Imaging; 2017 Feb; 30(1):26-38. PubMed ID: 27561753
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A joint FED watermarking system using spatial fusion for verifying the security issues of teleradiology.
    Viswanathan P; Krishna PV
    IEEE J Biomed Health Inform; 2014 May; 18(3):753-64. PubMed ID: 24043410
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An efficient and secure medical image protection scheme based on chaotic maps.
    Fu C; Meng WH; Zhan YF; Zhu ZL; Lau FC; Tse CK; Ma HF
    Comput Biol Med; 2013 Sep; 43(8):1000-10. PubMed ID: 23816172
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Research on testing the robustness of DICOM-e-mail secure teleradiology systems].
    Cao OL; Zhao J; Zhuang TG
    Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Jul; 30(4):280-3, 252. PubMed ID: 17039939
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Online signature verification and recognition: an approach based on symbolic representation.
    Guru DS; Prakash HN
    IEEE Trans Pattern Anal Mach Intell; 2009 Jun; 31(6):1059-73. PubMed ID: 19372610
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Public-Key-Infrastructure of the Radiological Society of Germany.
    Schütze B; Kämmerer M; Klos G; Mildenberger P
    Eur J Radiol; 2006 Mar; 57(3):323-8. PubMed ID: 16324813
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hash-based identification of sparse image tampering.
    Tagliasacchi M; Valenzise G; Tubaro S
    IEEE Trans Image Process; 2009 Nov; 18(11):2491-504. PubMed ID: 19635704
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and development of a secure DICOM-Network Attached Server.
    Tachibana H; Omatsu M; Higuchi K; Umeda T
    Comput Methods Programs Biomed; 2006 Mar; 81(3):197-202. PubMed ID: 16503366
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term verifiability of the electronic healthcare records' authenticity.
    Lekkas D; Gritzalis D
    Int J Med Inform; 2007; 76(5-6):442-8. PubMed ID: 17055778
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Authentication of digital medical images with digital signature technology.
    Smith JP
    Radiology; 1995 Mar; 194(3):771-4. PubMed ID: 7862977
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reversible watermarking for knowledge digest embedding and reliability control in medical images.
    Coatrieux G; Le Guillou C; Cauvin JM; Roux C
    IEEE Trans Inf Technol Biomed; 2009 Mar; 13(2):158-65. PubMed ID: 19272858
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.