BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 15362268)

  • 1. Performance of a digital PCO2/SPO2 ear sensor.
    Kocher S; Rohling R; Tschupp A
    J Clin Monit Comput; 2004 Apr; 18(2):75-9. PubMed ID: 15362268
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia.
    Rohling R; Biro P
    J Clin Monit Comput; 1999 Jan; 15(1):23-7. PubMed ID: 12578058
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Combining transcutaneous blood gas measurement and pulse oximetry.
    Eberhard P; Gisiger PA; Gardaz JP; Spahn DR
    Anesth Analg; 2002 Jan; 94(1 Suppl):S76-80. PubMed ID: 11900043
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
    Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
    Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients.
    Van Ginderdeuren F; Van Cauwelaert K; Malfroot A
    J Cyst Fibros; 2006 May; 5(2):125-8. PubMed ID: 16504602
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vivo investigation of ear canal pulse oximetry during hypothermia.
    Budidha K; Kyriacou PA
    J Clin Monit Comput; 2018 Feb; 32(1):97-107. PubMed ID: 28130679
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of motion on the performance of pulse oximeters in volunteers (revised publication).
    Barker SJ; Shah NK
    Anesthesiology; 1997 Jan; 86(1):101-8. PubMed ID: 9009945
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical validation of a digital transcutaneous PCO2/SpO2 ear sensor in adult patients after cardiac surgery.
    Baulig W; Schütt P; Roth HR; Hayoz J; Schmid ER
    J Clin Monit Comput; 2007 Oct; 21(5):303-9. PubMed ID: 17701383
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The revised digital transcutaneous PCO2/SpO2 ear sensor is a reliable noninvasive monitoring tool in patients after cardiac surgery.
    Roediger R; Beck-Schimmer B; Theusinger OM; Rusch D; Seifert B; Spahn DR; Schmid ER; Baulig W
    J Cardiothorac Vasc Anesth; 2011 Apr; 25(2):243-9. PubMed ID: 20851636
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs.
    Grosenbaugh DA; Muir WW
    Am J Vet Res; 1998 Feb; 59(2):205-12. PubMed ID: 9492938
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Independent component analysis applied to pulse oximetry in the estimation of the arterial oxygen saturation (SpO2)--a comparative study.
    Jensen T; Duun S; Larsen J; Haahr RG; Toft MH; Belhage B; Thomsen EV
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():4039-44. PubMed ID: 19964339
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of motion on the performance of pulse oximeters in volunteers.
    Barker SJ; Shah NK
    Anesthesiology; 1996 Oct; 85(4):774-81. PubMed ID: 8873547
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pulse oximeters' reliability in detecting hypoxemia and bradycardia: comparison between a conventional and two new generation oximeters.
    Bohnhorst B; Peter CS; Poets CF
    Crit Care Med; 2000 May; 28(5):1565-8. PubMed ID: 10834712
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Significant Delay in the Detection of Desaturation between Finger Transmittance and Earlobe Reflectance Oximetry Probes during Fiberoptic Bronchoscopy: Analysis of 104 Cases.
    Pertzov B; Brachfeld E; Unterman A; Gershman E; Abdel-Rahman N; Rosengarten D; Kramer MR
    Lung; 2019 Feb; 197(1):67-72. PubMed ID: 30474708
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of laminated disposable pulse-oximeter sensors.
    Russell GB; Graybeal JM
    Respir Care; 1995 Jul; 40(7):728-33. PubMed ID: 10144067
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Weaning with end-tidal CO2 and pulse oximetry.
    Thrush DN; Mentis SW; Downs JB
    J Clin Anesth; 1991; 3(6):456-60. PubMed ID: 1760168
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
    Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T
    PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Errors in 14 pulse oximeters during profound hypoxia.
    Severinghaus JW; Naifeh KH; Koh SO
    J Clin Monit; 1989 Apr; 5(2):72-81. PubMed ID: 2723709
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Development of a method of continuous monitoring of spontaneous respiration in the postoperative phase. 1. Normal values for cutaneous pO2- and pCO2-partial pressure together with pulse oximetry determined oxygen saturation in healthy young volunteers].
    Lehmann KA; Asoklis S; Grond S; Huttarsch H
    Anaesthesist; 1992 Mar; 41(3):121-9. PubMed ID: 1570883
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.