These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 15363076)

  • 1. Automatic recognition of abnormal respiratory events during sleep by a pacemaker transthoracic impedance sensor.
    Defaye P; Pépin JL; Poezevara Y; Mabo P; Murgatroyd F; Lévy P; Garrigue S
    J Cardiovasc Electrophysiol; 2004 Sep; 15(9):1034-40. PubMed ID: 15363076
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnosis of sleep-related breathing disorders by visual analysis of transthoracic impedance signals in pacemakers.
    Scharf C; Cho YK; Bloch KE; Brunckhorst C; Duru F; Balaban K; Foldvary N; Liu L; Burgess RC; Candinas R; Wilkoff BL
    Circulation; 2004 Oct; 110(17):2562-7. PubMed ID: 15492313
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A pacemaker transthoracic impedance sensor with an advanced algorithm to identify severe sleep apnea: the DREAM European study.
    Defaye P; de la Cruz I; Martí-Almor J; Villuendas R; Bru P; Sénéchal J; Tamisier R; Pépin JL
    Heart Rhythm; 2014 May; 11(5):842-8. PubMed ID: 24561163
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Feasibility of automated detection of advanced sleep disordered breathing utilizing an implantable pacemaker ventilation sensor.
    Shalaby A; Atwood C; Hansen C; Konermann M; Jamnadas P; Lee K; Willems R; Hartley J; Stahmann J; Kwok J; Ni Q; Neuzner J
    Pacing Clin Electrophysiol; 2006 Oct; 29(10):1036-43. PubMed ID: 17038134
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Utility of transthoracic impedance and novel algorithm for sleep apnea screening in pacemaker patient.
    Chen R; Chen K; Dai Y; Zhang S
    Sleep Breath; 2019 Sep; 23(3):741-746. PubMed ID: 30470999
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Feasibility of automated detection of sleep apnea using implantable pacemakers and defibrillators: a comparison with simultaneous polysomnography recording.
    Della Rocca DG; Albanese M; Placidi F; Forle GB; Di Biase L; Ribatti V; Santini L; Izzi F; Cicchini L; Lovecchio M; Valsecchi S; Lavalle C; Natale A; Mercuri NB; Romigi A
    J Interv Card Electrophysiol; 2019 Dec; 56(3):327-333. PubMed ID: 31646429
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Screening for sleep-related breathing disorders by transthoracic impedance recording integrated into a Holter ECG system.
    Mueller A; Fietze I; Voelker R; Eddicks S; Glos M; Baumann G; Theres H
    J Sleep Res; 2006 Dec; 15(4):455-62. PubMed ID: 17118103
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sleep apnea diagnosis using an ECG Holter device including a nasal pressure (NP) recording: validation of visual and automatic analysis of nasal pressure versus full polysomnography.
    Pépin JL; Defaye P; Vincent E; Christophle-Boulard S; Tamisier R; Lévy P
    Sleep Med; 2009 Jun; 10(6):651-6. PubMed ID: 19028140
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Utility of new-generation pacemakers in sleep apnea screening.
    Dias M; Gonçalves I; Amann B; Marques P; Martinho C; Leitão C; Basto RP; de Sousa J; Pinto P; Bárbara C
    Sleep Med; 2017 Sep; 37():27-31. PubMed ID: 28899536
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of a Holter-based methodology for evaluation of sleep apnoea syndrome.
    Szyszko A; Franceschini C; Gonzalez-Zuelgaray J
    Europace; 2009 Jan; 11(1):94-9. PubMed ID: 18971289
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Developing the portable type sleep apnea detector, and verifying the usefulness of the device].
    Koja S; Arakaki H; Ogura C
    Seishin Shinkeigaku Zasshi; 1997; 99(4):181-97. PubMed ID: 9170981
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Usefulness of ambulatory ECG in the diagnosis of sleep-related breathing disorders.
    Ozegowski S; Wilczyńska E; Piorunek T; Szymanowska K; Paluszkiewicz L
    Kardiol Pol; 2007 Nov; 65(11):1321-8; discussion 1329-30. PubMed ID: 18058583
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sleep disordered breathing and arrhythmia burden in pacemaker recipients.
    Padeletti M; Vignini S; Ricciardi G; Pieragnoli P; Zacà V; Emdin M; Fumagalli S; Jelic S
    Pacing Clin Electrophysiol; 2010 Dec; 33(12):1462-6. PubMed ID: 20735714
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Comparison of AutoSet with polysomnography in the diagnosis of sleep apnea syndrome].
    Wang H; Yang T; Cao K
    Zhonghua Jie He He Hu Xi Za Zhi; 1999 Jun; 22(6):344-6. PubMed ID: 11775823
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Observation-based nocturnal sleep inventory: screening tool for sleep apnea in elderly people.
    Onen SH; Dubray C; Decullier E; Moreau T; Chapuis F; Onen F
    J Am Geriatr Soc; 2008 Oct; 56(10):1920-5. PubMed ID: 18775037
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Successful screening of sleep-disordered breathing using a pacemaker-based algorithm in Japan.
    Taguchi Y; Matsushita K; Ishikawa T; Matsumoto K; Hosoda J; Iguchi K; Matsushita H; Kubota K; Sumita S; Ishigami T; Tamura K
    J Cardiol; 2019 May; 73(5):394-400. PubMed ID: 30630655
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term effects of dynamic atrial overdrive pacing on sleep-related breathing disorders in pacemaker or cardioverter defibrillator recipients.
    Sinha AM; Bauer A; Skobel EC; Markus KU; Ritscher G; Noelker G; Breithardt OA; Brachmann J; Stellbrink C
    Pacing Clin Electrophysiol; 2009 Mar; 32 Suppl 1():S219-22. PubMed ID: 19250100
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Screening of sleep apnea syndrome by ECG derived respiration of ambulatory electrocardiogram].
    Tong GM; Guo JH; Han F; Li J; Han X; Jia F; Zhang HC
    Zhonghua Yi Xue Za Zhi; 2006 Jun; 86(22):1545-8. PubMed ID: 16854281
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implantable cardioverter-defibrillator-computed respiratory disturbance index accurately identifies severe sleep apnea: The DASAP-HF study.
    D'Onofrio A; La Rovere MT; Emdin M; Capucci A; Sinagra G; Bianchi V; Pisanò ECL; Pieragnoli P; Tespili M; Luzi M; Talarico A; Zecchin M; Rapacciuolo A; Piacenti M; Indolfi C; Arias MA; Diemberger I; Checchinato C; Boriani G; Padeletti L
    Heart Rhythm; 2018 Feb; 15(2):211-217. PubMed ID: 29017928
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel device (SD-101) with high accuracy for screening sleep apnoea-hypopnoea syndrome.
    Agatsuma T; Fujimoto K; Komatsu Y; Urushihata K; Honda T; Tsukahara T; Nomiyama T
    Respirology; 2009 Nov; 14(8):1143-50. PubMed ID: 19818056
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.