BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 1536395)

  • 1. The response times during anaesthesia of pulse oximeters measuring oxygen saturations during hypoxaemic events.
    Broome IJ; Harris RW; Reilly CS
    Anaesthesia; 1992 Jan; 47(1):17-9. PubMed ID: 1536395
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Significant Delay in the Detection of Desaturation between Finger Transmittance and Earlobe Reflectance Oximetry Probes during Fiberoptic Bronchoscopy: Analysis of 104 Cases.
    Pertzov B; Brachfeld E; Unterman A; Gershman E; Abdel-Rahman N; Rosengarten D; Kramer MR
    Lung; 2019 Feb; 197(1):67-72. PubMed ID: 30474708
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lifebox pulse oximeter implementation in Malawi: evaluation of educational outcomes and impact on oxygen desaturation episodes during anaesthesia.
    Albert V; Mndolo S; Harrison EM; O'Sullivan E; Wilson IH; Walker IA
    Anaesthesia; 2017 Jun; 72(6):686-693. PubMed ID: 28439886
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The desaturation response time of finger pulse oximeters during mild hypothermia.
    MacLeod DB; Cortinez LI; Keifer JC; Cameron D; Wright DR; White WD; Moretti EW; Radulescu LR; Somma J
    Anaesthesia; 2005 Jan; 60(1):65-71. PubMed ID: 15601275
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulse oximetry to detect hypoxemia during apnea: comparison of finger and ear probes.
    Lindholm P; Blogg SL; Gennser M
    Aviat Space Environ Med; 2007 Aug; 78(8):770-3. PubMed ID: 17760284
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of Pulse Oximeters Intended for Hypoxemic Pediatric Patients.
    Harris BU; Char DS; Feinstein JA; Verma A; Shiboski SC; Ramamoorthy C
    Pediatr Crit Care Med; 2016 Apr; 17(4):315-20. PubMed ID: 26914626
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia.
    Gehring H; Hornberger C; Matz H; Konecny E; Schmucker P
    Respir Care; 2002 Jan; 47(1):48-60. PubMed ID: 11749687
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of desaturation and resaturation response times between transmission and reflectance pulse oximeters.
    Choi SJ; Ahn HJ; Yang MK; Kim CS; Sim WS; Kim JA; Kang JG; Kim JK; Kang JY
    Acta Anaesthesiol Scand; 2010 Feb; 54(2):212-7. PubMed ID: 19719816
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Potential errors in pulse oximetry. II. Effects of changes in saturation and signal quality.
    Webb RK; Ralston AC; Runciman WB
    Anaesthesia; 1991 Mar; 46(3):207-12. PubMed ID: 2014899
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Response time of pulse oximeters assessed using acute decompression.
    Young D; Jewkes C; Spittal M; Blogg C; Weissman J; Gradwell D
    Anesth Analg; 1992 Feb; 74(2):189-95. PubMed ID: 1731536
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo investigation of ear canal pulse oximetry during hypothermia.
    Budidha K; Kyriacou PA
    J Clin Monit Comput; 2018 Feb; 32(1):97-107. PubMed ID: 28130679
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The use of pulse oximetry in prilocaine induced methemoglobinemia].
    Rudlof B; Lampert R; Brandt L
    Anaesthesist; 1995 Dec; 44(12):887-91. PubMed ID: 8594966
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Arterial oxygen saturation during Cheyne-Stokes respiration in heart failure patients: does measurement site matter?
    Maestri R; Robbi E; Lovagnini M; Bruschi C; La Rovere MT; Pinna GD
    Sleep Med; 2019 Mar; 55():6-13. PubMed ID: 30739004
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical evaluation of pulse oximetry monitors on critically ill patients.
    De Pauw C; Poelaert J; Rolly G; Colardyn F
    Acta Anaesthesiol Belg; 1990; 41(1):33-9. PubMed ID: 2360390
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Forehead is as sensitive as finger pulse oximetry during general anesthesia.
    Sugino S; Kanaya N; Mizuuchi M; Nakayama M; Namiki A
    Can J Anaesth; 2004 May; 51(5):432-6. PubMed ID: 15128627
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the Ohmeda 3700 pulse oximeter: steady-state and transient response characteristics.
    Kagle DM; Alexander CM; Berko RS; Giuffre M; Gross JB
    Anesthesiology; 1987 Mar; 66(3):376-80. PubMed ID: 3826695
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Errors in 14 pulse oximeters during profound hypoxia.
    Severinghaus JW; Naifeh KH; Koh SO
    J Clin Monit; 1989 Apr; 5(2):72-81. PubMed ID: 2723709
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measuring arterial oxygenation in a high altitude field environment: comparing portable pulse oximetry with blood gas analysis.
    Ross EM; Matteucci MJ; Shepherd M; Barker M; Orr L
    Wilderness Environ Med; 2013 Jun; 24(2):112-7. PubMed ID: 23434169
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Perioperative hypoxaemia detected by intermittent pulse oximetry.
    McKenzie AJ
    Anaesth Intensive Care; 1989 Nov; 17(4):412-7. PubMed ID: 2596675
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Delays in the detection of hypoxemia due to site of pulse oximetry probe placement.
    Hamber EA; Bailey PL; James SW; Wells DT; Lu JK; Pace NL
    J Clin Anesth; 1999 Mar; 11(2):113-8. PubMed ID: 10386281
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.