These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 15373456)

  • 1. Exploring the importance of the relative solubility of matrix and analyte in MALDI sample preparation using HPLC.
    Hoteling AJ; Erb WJ; Tyson RJ; Owens KG
    Anal Chem; 2004 Sep; 76(17):5157-64. PubMed ID: 15373456
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of an on-target sample preparation system for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in conjunction with normal-flow peptide high-performance liquid chromatography for peptide mass fingerprint analyses.
    McComb ME; Perlman DH; Huang H; Costello CE
    Rapid Commun Mass Spectrom; 2007; 21(1):44-58. PubMed ID: 17133622
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Importance of solubility in the sample preparation of poly(ethylene terephthalate) for MALDI TOFMS.
    Hoteling AJ; Mourey TH; Owens KG
    Anal Chem; 2005 Feb; 77(3):750-6. PubMed ID: 15679340
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fractionation and solvent-free MALDI-MS analysis of polymers using liquid adsorption chromatography at critical conditions in combination with a multisample on-target homogenization/transfer sample preparation method.
    Trimpin S; Weidner SM; Falkenhagen J; McEwen CN
    Anal Chem; 2007 Oct; 79(19):7565-70. PubMed ID: 17822306
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Investigation of solvent-free MALDI-TOFMS sample preparation methods for the analysis of organometallic and coordination compounds.
    Hughes L; Wyatt MF; Stein BK; Brenton AG
    Anal Chem; 2009 Jan; 81(2):543-50. PubMed ID: 19086894
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reproducibility of serum protein profiling by systematic assessment using solid-phase extraction and matrix-assisted laser desorption/ionization mass spectrometry.
    Callesen AK; Christensen Rd; Madsen JS; Vach W; Zapico E; Cold S; Jørgensen PE; Mogensen O; Kruse TA; Jensen ON
    Rapid Commun Mass Spectrom; 2008; 22(3):291-300. PubMed ID: 18181248
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sample preparation effects in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry of partially depolymerised methyl cellulose.
    Momcilovic D; Wittgren B; Wahlund KG; Karlsson J; Brinkmalm G
    Rapid Commun Mass Spectrom; 2003; 17(11):1116-24. PubMed ID: 12772266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. New aspects in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: a universal solvent-free sample preparation.
    Trimpin S; Rouhanipour A; Az R; Räder HJ; Müllen K
    Rapid Commun Mass Spectrom; 2001; 15(15):1364-73. PubMed ID: 11466797
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Matrix/analyte ratio influencing polymer molecular weight distribution in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
    Schlosser G; Jakab A; Pocsfalvi G; Vékey K; Hudecz F; Mezo G
    Rapid Commun Mass Spectrom; 2009 May; 23(9):1249-54. PubMed ID: 19306286
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterization of humic substances by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
    Mugo SM; Bottaro CS
    Rapid Commun Mass Spectrom; 2004; 18(20):2375-82. PubMed ID: 15386633
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Toward prediction: using chemometrics for the optimization of sample preparation in MALDI-TOF MS of synthetic polymers.
    Brandt H; Ehmann T; Otto M
    Anal Chem; 2010 Oct; 82(19):8169-75. PubMed ID: 20879802
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantification of peptides for the monitoring of protease-catalyzed reactions by matrix-assisted laser desorption/ionization mass spectrometry using ionic liquid matrixes.
    Tholey A; Zabet-Moghaddam M; Heinzle E
    Anal Chem; 2006 Jan; 78(1):291-7. PubMed ID: 16383339
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of peptide retention time prediction for protein identification by off-line reversed-phase HPLC-MALDI MS/MS.
    Krokhin OV; Ying S; Cortens JP; Ghosh D; Spicer V; Ens W; Standing KG; Beavis RC; Wilkins JA
    Anal Chem; 2006 Sep; 78(17):6265-9. PubMed ID: 16944911
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Coupling of nanoflow liquid chromatography to matrix-assisted laser desorption/ionization mass spectrometry: real-time liquid chromatography run mapping on a MALDI plate.
    Nägele E; Vollmer M
    Rapid Commun Mass Spectrom; 2004; 18(24):3008-14. PubMed ID: 15536631
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coupling of protein HPLC to MALDI-TOF MS using an on-target device for fraction collection, concentration, digestion, desalting, and matrix/analyte cocrystallization.
    Perlman DH; Huang H; Dauly C; Costello CE; McComb ME
    Anal Chem; 2007 Mar; 79(5):2058-66. PubMed ID: 17256876
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Capillary-scale frontal affinity chromatography/MALDI tandem mass spectrometry using protein-doped monolithic silica columns.
    Kovarik P; Hodgson RJ; Covey T; Brook MA; Brennan JD
    Anal Chem; 2005 May; 77(10):3340-50. PubMed ID: 15889927
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rapid identification of siderophores by combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry.
    Hayen H; Volmer DA
    Rapid Commun Mass Spectrom; 2005; 19(5):711-20. PubMed ID: 15700233
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved peptide mass fingerprinting matches via optimized sample preparation in MALDI mass spectrometry.
    Padliya ND; Wood TD
    Anal Chim Acta; 2008 Oct; 627(1):162-8. PubMed ID: 18790140
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Matrix-assisted and polymer-assisted laser desorption/ionization time-of-flight mass spectrometric analysis of low molecular weight polystyrenes and polyethylene glycols.
    Woldegiorgis A; Löwenhielm P; Björk A; Roeraade J
    Rapid Commun Mass Spectrom; 2004; 18(23):2904-12. PubMed ID: 15529416
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modified silver nanoparticle as a hydrophobic affinity probe for analysis of peptides and proteins in biological samples by using liquid-liquid microextraction coupled to AP-MALDI-ion trap and MALDI-TOF mass spectrometry.
    Shrivas K; Wu HF
    Anal Chem; 2008 Apr; 80(7):2583-9. PubMed ID: 18324794
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.