BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 15376439)

  • 1. Passive remote sensing of pollutant clouds by Fourier-transform infrared spectrometry: signal-to-noise ratio as a function of spectral resolution.
    Harig R
    Appl Opt; 2004 Aug; 43(23):4603-10. PubMed ID: 15376439
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Passive remote sensing of VOC in atmosphere by FTIR spectrometry].
    Gao MG; Liu WQ; Zhang TS; Liu JG; Lu YH; Zhu J; Lian Y; Lu F
    Guang Pu Xue Yu Guang Pu Fen Xi; 2005 Jul; 25(7):1042-4. PubMed ID: 16241050
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Data compressive paradigm for multispectral sensing using tunable DWELL mid-infrared detectors.
    Jang WY; Hayat MM; Godoy SE; Bender SC; Zarkesh-Ha P; Krishna S
    Opt Express; 2011 Sep; 19(20):19454-72. PubMed ID: 21996886
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Computer simulation for infrared spectra of pollution clouds with FTIS remote detection].
    Zhang J; Jiang FH; Gong YJ; Dai ZH
    Guang Pu Xue Yu Guang Pu Fen Xi; 2001 Oct; 21(5):617-9. PubMed ID: 12945311
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Remote detection of heated ethanol plumes by airborne passive Fourier transform infrared spectrometry.
    Tarumi T; Small GW; Combs RJ; Kroutil RT
    Appl Spectrosc; 2003 Nov; 57(11):1432-41. PubMed ID: 14658159
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Passive standoff detection of SF6 at a distance of 5.7 km by differential Fourier transform infrared radiometry.
    Lavoie H; Puckrin E; Thériault JM; Bouffard F
    Appl Spectrosc; 2005 Oct; 59(10):1189-93. PubMed ID: 16274529
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Error analysis for estimation of trace vapor concentration pathlength in stack plumes.
    Gallagher NB; Wise BM; Sheen DM
    Appl Spectrosc; 2003 Jun; 57(6):614-21. PubMed ID: 14658692
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Miniaturization of holographic Fourier-transform spectrometers.
    Agladze NI; Sievers AJ
    Appl Opt; 2004 Dec; 43(36):6568-79. PubMed ID: 15646777
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The application of wavelet analysis of remote detection of pollution clouds].
    Zhang J; Jiang F
    Guang Pu Xue Yu Guang Pu Fen Xi; 2001 Aug; 21(4):495-7. PubMed ID: 12945271
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Reconstruction algorithms of computed tomography of remote sensing FTIR].
    Huang ZH; Li Y; Wang JD
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Dec; 22(6):973-5. PubMed ID: 12914178
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Remote sensing FTIR and computed tomography for air pollution].
    Huang ZH; Wang JD; Chen ZR
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Jun; 22(3):407-8. PubMed ID: 12938317
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Real-time fourier transform-infrared analysis of carbon monoxide and nitric oxide in sidestream cigarette smoke.
    Thompson BT; Mizaikoff B
    Appl Spectrosc; 2006 Mar; 60(3):272-8. PubMed ID: 16608570
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Retrievals for the atmospheric chemistry experiment Fourier-transform spectrometer.
    Boone CD; Nassar R; Walker KA; Rochon Y; McLeod SD; Rinsland CP; Bernath PF
    Appl Opt; 2005 Nov; 44(33):7218-31. PubMed ID: 16318195
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Investigation on remote measurement of air pollution by a method of infrared passive scanning imaging].
    Jiao Y; Xu L; Gao MG; Feng MC; Jin L; Tong JJ; Li S
    Guang Pu Xue Yu Guang Pu Fen Xi; 2012 Jul; 32(7):1754-7. PubMed ID: 23016318
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Statistical comparison of Fourier transform infrared spectra.
    Spencer RG; Calton EF; Camacho NP
    J Biomed Opt; 2006; 11(6):064023. PubMed ID: 17212546
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Studies on spectral characteristics of solid propellant by remote sensing FTIR].
    Li Y; Huang ZH; Zhou XT; Wang JD
    Guang Pu Xue Yu Guang Pu Fen Xi; 2005 Feb; 25(2):201-3. PubMed ID: 15852856
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Far-infrared sensor for cirrus (FIRSC): an aircraft-based Fourier-transform spectrometer to measure cloud radiance.
    Vanek MD; Nolt IG; Tappan ND; Ade PA; Gannaway FC; Hamilton PA; Lee C; Davis JE; Predko S
    Appl Opt; 2001 May; 40(13):2169-76. PubMed ID: 18357224
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment and statistical modeling of the relationship between remotely sensed aerosol optical depth and PM2.5 in the eastern United States.
    Paciorek CJ; Liu Y;
    Res Rep Health Eff Inst; 2012 May; (167):5-83; discussion 85-91. PubMed ID: 22838153
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Combustion temperature measurement of pyrotechnic composition using remote sensing Fourier transform infrared spectrometry].
    Zhou XL; Li Y; Liu ZL; Zhu CJ; Wang JD; Lu CX
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Oct; 22(5):764-6. PubMed ID: 12938424
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Short-range remote detection of liquid surface contamination by active imaging Fourier transform spectrometry.
    Harig R; Braun R; Dyer C; Howle C; Truscott B
    Opt Express; 2008 Apr; 16(8):5708-14. PubMed ID: 18542678
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.