These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

301 related articles for article (PubMed ID: 15376727)

  • 21. The influence of irradiation dose on mechanical properties and wear resistance of molded and extruded ultra high molecular weight polyethylene.
    Xiong L; Xiong D
    J Mech Behav Biomed Mater; 2012 May; 9():73-82. PubMed ID: 22498285
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of malalignment on stresses in polyethylene component of total knee prostheses--a finite element analysis.
    Liau JJ; Cheng CK; Huang CH; Lo WH
    Clin Biomech (Bristol, Avon); 2002 Feb; 17(2):140-6. PubMed ID: 11832264
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Optimization of the geometry of total knee implant in the sagittal plane using FEA.
    Dargahi J; Najarian S; Amiri S
    Biomed Mater Eng; 2003; 13(4):439-49. PubMed ID: 14646058
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A two-dimensional model of cyclic strain accumulation in ultra-high molecular weight polyethylene knee replacements.
    Reeves EA; Barton DC; FitzPatrick DP; Fisher J
    Proc Inst Mech Eng H; 1998; 212(3):189-98. PubMed ID: 9695638
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses.
    Wang A; Stark C; Dumbleton JH
    Proc Inst Mech Eng H; 1996; 210(3):141-55. PubMed ID: 8885651
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of ultra-high molecular weight polyethylene thickness on contact mechanics in total knee replacement.
    El-Deen M; García-Fiñana M; Jin ZM
    Proc Inst Mech Eng H; 2006 Oct; 220(7):733-42. PubMed ID: 17117763
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A quantitative technique for reporting surface degradation patterns of UHMWPE components of retrieved total knee replacements.
    Cornwall GB; Bryant JT; Hansson CM; Rudan J; Kennedy LA; Cooke TD
    J Appl Biomater; 1995; 6(1):9-18. PubMed ID: 7703542
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator.
    Benson LC; DesJardins JD; Harman MK; LaBerge M
    Proc Inst Mech Eng H; 2002; 216(6):409-18. PubMed ID: 12502005
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Can Sequentially-irradiated and Annealed Highly Cross-linked Polyethylene Inserts Thinner than Eight-millimeters Be Utilized in Total Knee Arthroplasty?
    Sayeed SA; Jauregui JJ; Korduba LA; Essner A; Harwin SF; Delanois RE; Mont MA
    Surg Technol Int; 2015 May; 26():329-35. PubMed ID: 26055028
    [TBL] [Abstract][Full Text] [Related]  

  • 30. In vitro assessment of proximal polyethylene contact surface areas and stresses in mobile bearing knees.
    Chapman-Sheath PJ; Bruce WJ; Chung WK; Morberg P; Gillies RM; Walsh WR
    Med Eng Phys; 2003 Jul; 25(6):437-43. PubMed ID: 12787981
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Influences of the temporal nature of the applied load and the tibial baseplate material on the stress distribution in a three-dimensional model of the human knee joint containing a prosthetic replacement.
    Nambu SN; Lewis G
    Biomed Mater Eng; 2004; 14(2):203-17. PubMed ID: 15156111
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Fractography and oxidative analysis of gamma inert sterilized posterior-stabilized tibial insert post fractures: report of two cases.
    Ansari F; Chang J; Huddleston J; Van Citters D; Ries M; Pruitt L
    Knee; 2013 Dec; 20(6):609-13. PubMed ID: 24220187
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Towards an accurate understanding of UHMWPE visco-dynamic behaviour for numerical modelling of implants.
    Quinci F; Dressler M; Strickland AM; Limbert G
    J Mech Behav Biomed Mater; 2014 Apr; 32():62-75. PubMed ID: 24434602
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces.
    Wang FC; Jin ZM; McEwen HM; Fisher J
    Proc Inst Mech Eng H; 2003; 217(6):477-90. PubMed ID: 14702985
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Increased total knee arthroplasty ultra-high molecular weight polyethylene wear using a clinically relevant hyaluronic acid simulator lubricant.
    DesJardins J; Aurora A; Tanner SL; Pace TB; Acampora KB; Laberge M
    Proc Inst Mech Eng H; 2006 Jul; 220(5):609-23. PubMed ID: 16898218
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A comparison of contact pressures in tibial and patellar total knee components before and after service in vivo.
    McNamara JL; Collier JP; Mayor MB; Jensen RE
    Clin Orthop Relat Res; 1994 Feb; (299):104-13. PubMed ID: 8119003
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure.
    Kang L; Galvin AL; Brown TD; Fisher J; Jin ZM
    Proc Inst Mech Eng H; 2008 Oct; 222(7):1049-64. PubMed ID: 19024153
    [TBL] [Abstract][Full Text] [Related]  

  • 38. CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.
    Schwiesau J; Fritz B; Kutzner I; Bergmann G; Grupp TM
    Biomed Res Int; 2014; 2014():567374. PubMed ID: 25506594
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of sliding locus on subsurface crack formation in ultra-high-molecular-weight polyethylene knee component.
    Todo S; Tomita N; Kitakura T; Yamano Y
    Biomed Mater Eng; 1999; 9(1):13-20. PubMed ID: 10436849
    [TBL] [Abstract][Full Text] [Related]  

  • 40. In vitro simulation of contact fatigue damage found in ultra-high molecular weight polyethylene components of knee prostheses.
    Currier JH; Duda JL; Sperling DK; Collier JP; Currier BH; Kennedy FE
    Proc Inst Mech Eng H; 1998; 212(4):293-302. PubMed ID: 9769697
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.